EATON 2016 Arrow Hart Buyers Guide H-1 SECTIONHEATON 2016 Arrow Hart Buyers Guide HSECTIONG round Fault Circuit Inter r upters (GFCIs)H-1 GFCI familiesH-2 Build-to-specH-3 ArrowLink modular connectorsH-4 Specification grade GFCIsH-72-pole, 3-wire groundingRating15A, 125V/ACNEMA 5-15H-7, H-820A, 125V/ACNEMA 5-20H-7, H-8 Combination switch/GFCI, 2-pole 3-wire groundingRating15A, 125V/ACNEMA 5-15H-8 Blank face (dead-front), 2-pole, 3-wire grounding20A, 125V/ACH-8 Hospital grade specification GFCIsH-92-pole, 3-wire groundingRating15A, 125V/ACNEMA 5-15H-1020A, 125V/ACNEMA 5-20H-10 Industrial grade portable GFCIsH-1115A portable GFCIsRatingPlug series, single or tri-tap connectorNEMA 5-15H-12 Plug series, field wireableNEMA 5-15H-12 Inline series, single or tri-tap connectorNEMA 5-15H-12 Inline series, field wireableNEMA 5-15H-1220A portable GFCIsRatingInline series, field wireableNON-NEMAH-13 Inline series, molded straight bladeNEMA 5-20H-13 Inline series, molded lockingNEMA L5-20H-1330A portable GFCIsRatingInline series, field wireable, single phaseNON-NEMAH-14 Inline series, molded lockingNON-NEMAH-14 Watertight portable GFCIsRating15A, straight bladeNEMA 5-15H-1520A, straight bladeNEMA 5-20H-1520A, lockingNEMA L5-20H-15

H-2 www.eaton.com EATON 2016 Arrow Hart Buyers Guide www.eaton.comarrowhart SECTION H Specification grade GFCIs Arrow Hart GFCI receptacles meet the stringent UL943 (GFCI) standards, plus our broad line provides solutions

Tags:

  Section, Industreis, Receptacles, Cooper industries, Cooper

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SECTION - Cooper Industries

1 EATON 2016 Arrow Hart Buyers Guide H-1 SECTIONHEATON 2016 Arrow Hart Buyers Guide HSECTIONG round Fault Circuit Inter r upters (GFCIs)H-1 GFCI familiesH-2 Build-to-specH-3 ArrowLink modular connectorsH-4 Specification grade GFCIsH-72-pole, 3-wire groundingRating15A, 125V/ACNEMA 5-15H-7, H-820A, 125V/ACNEMA 5-20H-7, H-8 Combination switch/GFCI, 2-pole 3-wire groundingRating15A, 125V/ACNEMA 5-15H-8 Blank face (dead-front), 2-pole, 3-wire grounding20A, 125V/ACH-8 Hospital grade specification GFCIsH-92-pole, 3-wire groundingRating15A, 125V/ACNEMA 5-15H-1020A, 125V/ACNEMA 5-20H-10 Industrial grade portable GFCIsH-1115A portable GFCIsRatingPlug series, single or tri-tap connectorNEMA 5-15H-12 Plug series, field wireableNEMA 5-15H-12 Inline series, single or tri-tap connectorNEMA 5-15H-12 Inline series, field wireableNEMA 5-15H-1220A portable GFCIsRatingInline series, field wireableNON-NEMAH-13 Inline series, molded straight bladeNEMA 5-20H-13 Inline series, molded lockingNEMA L5-20H-1330A portable GFCIsRatingInline series, field wireable, single phaseNON-NEMAH-14 Inline series, molded lockingNON-NEMAH-14 Watertight portable GFCIsRating15A, straight bladeNEMA 5-15H-1520A, straight bladeNEMA 5-20H-1520A, lockingNEMA L5-20H-1520A.

2 LockingNEMA L6-20H-1530A, lockingNEMA L5-30H-1530A, lockingNEMA L6-30H-15 Specification informationH-16 Table of EATON 2016 Arrow Hart Buyers Guide SECTIONHS pecification grade GFCIsArrow Hart GFCI receptacles meet the stringent UL943 (GFCI) standards, plus our broad line provides solutions for commercial, industrial and institutional specification grade GFCIsDesigned for safety and reliability, Arrow Hart GFCI receptacles meet the strict standards of UL943 (GFCI) and UL498 (hospital grade receptacle standards). Plus, our broad line provides solutions including tamper resistant, ArrowLink modular and NAFTA compliant grade portable GFCIsSpecifically designed to protect personnel and equipment from ground fault hazards in indoor or outdoor job site applications. GFCI familiesProtecting people from electrical shock hazardsArrow Hart s complete offering of ground fault circuit interrupters (GFCIs)

3 Is built to meet every need in commercial, industrial and institutional settings, whether permanent or temporary and is fully compliant with the latest UL943 standards for GFCIs, including self-testing functionalitySelf-test GFCI UL943 standardsArrow Hart GFCI Auto-monitoring function that allows periodic automatic testing of GFCI Auto-monitoring function that allows periodic automatic testing of GFCI Automatic test initiates within 5 seconds of power availability to the line or load terminals and repeats at least every 3 hours Automatic test initiates within 1 second of power availability to the line or load terminals and repeats every hours If auto-monitoring detects a problem, GFCI will have power denial (trip with the inability to reset) Visual and/or audible indicator will alert if there is a problem Trip with the ability to reset subject to the next auto-monitoring test cycle or repeatedly trip If auto-monitoring detects a problem, GFCI will have power denial (trip with the inability to reset) Visual indicator will alert if there is a H-3 SECTIONHEATON 2016 Arrow Hart Buyers Guide TR" mold mark provides quick visual confirmation of tamper resistance when installed.

4 WR" identifier quickly indicates during inspections that a weather resistant receptacle has been the TR" mold mark and WR" identifier are clearly visible in the finished installation, indicating double-layer protection for maximum receptacles , switches, GFCIs & SPD devicesA) Commercial locations 2014 NEC (B) guest rooms & guest suites (C) child care facilities (C) pediatric locationsReceptacles located in these areas shall be listed under tamper resistant or employ a listed tamper resistant ) Dwelling units 2014 NEC - (A)In all areas specified in all 125-volt, 15- and 20-amp receptacles shall be listed tamper resistant ) Damp or wet locations 2014 NEC - 15- and 20-amp, 125- and 250-volt non-locking receptacles installed in wet or damp locations shall be weather resistant receptacles . Modified at the factory to improve efficiency and speed production at the job site.

5 Arrow Hart s build-to-spec program provides customized device solutions to simplify your project and maximize your bottom resistant, weather resistant, and tamper & weather resistant receptaclesHow the tamper resistant system works:Shutters restrict access in closed of object in any one side will not open of two-bladed plug or grounding plug will open people from electrical shock hazardsGFCI optionsotee:N Arrow Hart 20A 125V NEMA 5-20 white GFCI recepta-cle, with wire leads and push-in connec-tors, without mount-ing screws, ears, or grounding sample numbere: SGF20 WXZR emove mounting screwsGPRemove earsRemove ground clipAdd push-in connector**SGF20 WPSOLAdd 6" leadsPSOL = #12 AWG solid PSTR = #12 AWG strandedBase catalog number(including device color)Compliances, specifications and availability are subject to change without notice.

6 **For use with leaded devices only. Add PSOL to back of device catalog number for 6" of #12 AWG solid or PSTR for 6" of #12 AWG stranded. (Example: 8300 BLSPSOL + build to spec option s). All devices are bulk packed 50 pieces per carton. Minimum order quantity is 100 pieces. Orders under 500 pieces ship within 5 days with larger quantities typically within 10 EATON 2016 Arrow Hart Buyers Guide SECTIONHA rrowLink modular connectorsArrowLink 50% Time savingse:SPD accelerates both rough-in & trim out installation Efficient designe:Low profile connection with feed-through capabilityEase of installatione:No more twist-on wire connectors30% Reduction in wire volume inside the boxArrow Hart s factory terminated ArrowLink system revolutionizes device installation, unleashing ground breaking labor savings in installation and maintenance by eliminating traditional pigtailing, terminal connections and taping.

7 Use ArrowLink on your next job to reduce labor costs, eliminate installation errors, save money and win!ArrowLink SPD benefitsCompliances, specifications and availability are subject to change without polycarbonate housingColor coded terminals for consistent, reliable connectionsCopper alloy contacts for superior wire retention and minimized heat riseColor coded terminal screws6", #12 AWG ground lead with ring terminal and captive ground screwTerminal accommodation #12 - #14 AWG, solid onlyTerminal accommodation #12 - #14 AWG, solid or strandedColor coded terminal screws guard capsCut-away of MCR300 FTPI Push-in terminalCut-away of MCR300 FTST Screw terminal1. Select a device to ArrowLink enable. Catalog pages identify available products-simply add an M to the catalog number and the devices will be factory enabled with the ArrowLink device-side connection.

8 (For GFCIs add MOD suffix)2. Choose from leaded or unleaded ArrowLink connector versions in screw-down or push-in Place your order and get your ArrowLink devices in bulk packed boxes, shipped within 5 days of receipt of order! How to orderArrow Hart s factory terminated ArrowLink system revolutionizes device installation, unleashing ground breaking labor savings in installation and maintenance by eliminating traditional pigtailing, terminal connections and taping. Use ArrowLink on your next job to reduce labor costs, eliminate installation errors, save money and win!Features & H-5 SECTIONHEATON 2016 Arrow Hart Buyers Guide ArrowLink modular connectorsTotal time required to install 500 ArrowLink SPD HoursTotal time required toinstall 500 pigtail HoursTime saved with Hours0e:501e:150e:051e:501e:101e:05 Cutting & stripping pigtailsInstall wire connectorsTerminateconductorsMountdevice sTerminateconductorsAttachdeviceMountdev ices4e:55/Receptacle2e:25/Receptacle1e.

9 05 Traditional pigtail installationArrowLink SPD installationArrowLink SPD comparative labor savings analysisLeaded ArrowLink receptacle connectorsDevice typeDescriptionCatalog wire leads 125V MCR125 SOLS tranded wire leads 125V MCR125 STRS olid wire leads 250V MCR250 SOLS tranded wire leads 250V MCR250 STRA rrowLink SPD receptacle connectorsDevice typeDescriptionCatalog terminal MCR300 FTSTS crew terminal, no ground conductor MCR300 FTSTNGPush-in MCR300 FTPIPush-in, no ground conductor MCR300 FTPINGA rrowLink accessoriesDevice typeDescriptionCatalog testerTests receptacle & ArrowLink connectors ALTESTERA rrowLink SPD benefitsCompliances, specifications and availability are subject to change without Leaded ArrowLink connectorMCR300 FTST Screw terminalMCR300 FTPI Push-in terminalALTESTER Circuit EATON 2016 Arrow Hart Buyers Guide SECTIONHA dditional features & benefits Meets and exceeds 10 kA short circuit testing and underwriters laboratories (UL)

10 2006 UL943 safety standards Performs periodic self tests to ensure integrity of GFCI protection if no ground-fault protection is detected, the device will trip, will not reset and the status indicator light will glow amber Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full protection Test and reset buttons are color matched to provide superior aesthetics Longer, wider bridge strap provides 40% more contact area with wallboard, virtually eliminating floating installations Exclusive built-in wire stripper provides fast stripping of wire without tools Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly Tri-combo head terminal and mounting screwsGround fault circuit interrupter features & benefitsSpecification grade GFCIsGFCIs provide state-of-the-art, dependable electrical shock protectionIn addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected powerCompliances, specifications and availability are subject to change without side terminals are backed out and staked for fast installationHorizontal test/reset button alignment provides larger unobstructed areaAutomatic grounding system eliminates need for bonding jumper in grounded metal enclosure.