RatingsPage BottomBXUVC - Fire-resistance RatingsSee General Information for Fire-resistance RatingsDesign No. F910 March 27, 2015 Restrained assembly Rating - 3 h, 2 h, 1-1/2 h, 1 h (See Item 4) unrestrained assembly Rating - 0 h (See Item 3) unrestrained Beam Rating - 1-1/2 h, 1 h (See Item 4)Load Restriction - 89 percent Beam W150x37, minimum Normal-Density or Low-Density Concrete Normal-density concrete, carbonate or siliceous aggregate, 2400 50 kg/m3 density, 24 MPa nominal compressive strength. Low-density concrete, expanded shale, clay or slate aggregate by rotary kiln method, 1760 50 kg/m3 density, 24 MPa nominal compressive Wire Fabric 152 by 152 wire Steel Floor Units (CHWXC).

For W150x37 Restrained Assembly Rating, h Unrestrained Assembly Rating, h Unrestrained Beam Rating, h Min Concrete Cover Thickness, mm Min Dry Thickness of

Tags:

  General, Information, Resistance, Fire, Assembly, Unrestrained, General information for fire resistance, Unrestrained assembly

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of See General Information for Fire-resistance …

1 RatingsPage BottomBXUVC - Fire-resistance RatingsSee General Information for Fire-resistance RatingsDesign No. F910 March 27, 2015 Restrained assembly Rating - 3 h, 2 h, 1-1/2 h, 1 h (See Item 4) unrestrained assembly Rating - 0 h (See Item 3) unrestrained Beam Rating - 1-1/2 h, 1 h (See Item 4)Load Restriction - 89 percent Beam W150x37, minimum Normal-Density or Low-Density Concrete Normal-density concrete, carbonate or siliceous aggregate, 2400 50 kg/m3 density, 24 MPa nominal compressive strength. Low-density concrete, expanded shale, clay or slate aggregate by rotary kiln method, 1760 50 kg/m3 density, 24 MPa nominal compressive Wire Fabric 152 by 152 wire Steel Floor Units (CHWXC).

2 Composite or noncomposite floor units. mm thick fluted sections welded to supports with 19 mm puddle welds spaced 300 mm OC. Adjacent units button punched or welded 915 mm OC along side joints. When the maximum clear span of the steel floor units is less than or equal to the tested span of 2900 mm, the unrestrained assembly rating is increased to 1 h and 1-1/2 h to match the unrestrained beam individual manufacturer's listing for those profiles that may be used in this CANAM INCNEW MILLENNIUM BUILDING SYSTEMS L L CVICWEST INC4. Thin-Flim Intumescent Coatings (CAVCC). Intumescent coating designated "A/D FIREFILM II", "A/D FIREFILM III" or "A/D FIREFILM III C" applied to steel beam in accordance with manufacturer's instructions to the minimum dry film thicknesses shown below.

3 A/D fire PROTECTION SYSTEMS INCPage 1 of - Fire-resistance Ratings08/04/2015 W150x37 RestrainedAssemblyRating, hUnrestrainedAssemblyRating, hUnrestrainedBeamRating, hMin ConcreteCover Thickness, mmMin Dry Thickness ofA/D FIREFILM II, III or III Con Beam, mmNormal-DensityLow-Density30 (see Item 3)1-1/2114 Not (see Item 3) (see Item 3) (see Item 3) Shear Connectors (optional) (not shown) - Studs 13 mm diameter by 100 mm long, headed type. Welded to top flange of beam through steel floor units for a maximum composite action of 40 percent between the Steel Beam and Concrete. Shear studs are not permitted for Restarined assembly Rating greater than 2 hour.

4 Last Updated on 2015-03-27 Questions?Print this pageTerms of UsePage TopCopyright 2015 Underwriters Laboratories of Canada the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional Information regarding this product's appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under ULC's Follow-Up Service. Only those products bearing the ULC Mark should be considered to be Listed and covered under ULC's Follow-Up Service. Always look for the Mark on the permits the reproduction of the material contained in the ULC Online Directories subject to the following conditions: 1.

5 The Guide Information , Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the ULC Online Directories with permission from Underwriters Laboratories of Canada Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2015 Underwriters Laboratories of Canada Inc."Page 2 of - Fire-resistance Ratings08/04/2015


Related search queries