Example: barber

Selection diagram for NA-NB series items sold …

4 NANBG eneral Catalogue 2015-20161190HH-W5 flexible rod with needleACTUATORSS election diagram for NA-NB series items sold assembled0AA 0AB 0 AC 0AE 0BB 0BE 0BG 0CB 0CH short plungerplunger long plungerplunger with external gasket roller plunger roller plunger with rubber gasket roller plunger with rubber gasketroller lever angled roller lever 2KA 2KB 2KC 2KD 2KE 2KF 2KG 2KH 2KP plastic swivelling lever, straight, with roller 18 mmadjustable metal swivelling lever, straight, with roller 18 mmadjustable metal swivelling lever, shaped, with roller 14 mmadjustable metal swivelling lever, shaped, with roller 14 mmadjustable metal swivelling lever, shaped, with roller 20 mmadjustable metal swivelling lever, straight, with roller 20 mmadjustable metal swivelling lever, shaped, with roller 20 mmadjustable metal swivelling lever, shaped, with roller 20 mmmetal swivelling lever, straight, with roller 20 mm, extended adjustment0AB-W5 0BB-H0W5 0BB-W5 plunger roller plunger roller plunger 0HE-W5 flexible rod 0HB-W5 flexible rod with plastic tip Metal modular prewired switches NA-NB seriesB11 G11 H11 L11 1NO+1 NCsnap action1NO+1 NCslow action1NO+1 NCslow action overlapped1NO+1 NCslow action, closerB02 G02 2 NCsnap action2 NCslow actionB22 G22 H22 L22 2NO+2 NCsnap action2NO+2 NCslow action2NO+2 NCslow action overla

4 NA NB 119 General Catalogue 2015-2016 0HH-W5 flexible rod with needle ACTUATORS Selection diagram for NA-NB series items sold assembled 0AA 0AB 0 AC 0AE 0BB 0BE 0BG 0CB 0CH

Tags:

  Series, Time, Selection, Assembled, Diagrams, Sold, Selection diagram for na nb series items sold, Selection diagram for na nb series items sold assembled

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Selection diagram for NA-NB series items sold …

1 4 NANBG eneral Catalogue 2015-20161190HH-W5 flexible rod with needleACTUATORSS election diagram for NA-NB series items sold assembled0AA 0AB 0 AC 0AE 0BB 0BE 0BG 0CB 0CH short plungerplunger long plungerplunger with external gasket roller plunger roller plunger with rubber gasket roller plunger with rubber gasketroller lever angled roller lever 2KA 2KB 2KC 2KD 2KE 2KF 2KG 2KH 2KP plastic swivelling lever, straight, with roller 18 mmadjustable metal swivelling lever, straight, with roller 18 mmadjustable metal swivelling lever, shaped, with roller 14 mmadjustable metal swivelling lever, shaped, with roller 14 mmadjustable metal swivelling lever, shaped, with roller 20 mmadjustable metal swivelling lever, straight, with roller 20 mmadjustable metal swivelling lever, shaped, with roller 20 mmadjustable metal swivelling lever, shaped, with roller 20 mmmetal swivelling lever, straight, with roller 20 mm, extended adjustment0AB-W5 0BB-H0W5 0BB-W5 plunger roller plunger roller plunger 0HE-W5 flexible rod 0HB-W5 flexible rod with plastic tip Metal modular prewired switches NA-NB seriesB11 G11 H11 L11 1NO+1 NCsnap action1NO+1 NCslow action1NO+1 NCslow action overlapped1NO+1 NCslow action, closerB02 G02 2 NCsnap action2 NCslow actionB22 G22 H22 L22 2NO+2 NCsnap action2NO+2 NCslow action2NO+2 NCslow action overlapped2NO+2 NCslow action, closeron requestB12 G12 H12 L12 1NO+2 NCsnap action1NO+2 NCslow action1NO+2 NCslow action overlapped1NO+2 NCslow action, closerproduct optionsaccessory sold separatelyCONNECTORSCABLE connector with cableDNblack PVC cable, IEC 60332 1 (standard)DGgrey PVC cable, CEI 20 22 II DHgrey PUR cable, halogen free DRcable for railway applications (EN 50306 4)

2 CONTACT BLOCKSDMKSMKSAKM12 connector rightM12 connector bottomAMP connector, bottomFor Info: Phone: 800-221-0487 Fax: 718-672-63704NA B110AB-DN2GR7T6W5120 General Catalogue 2015-2016 Contact blocksB 111NO+1NC, snap actionB022NC, snap actionB121NO+2NC, snap actionB222NO+2NC, snap actionBA11NO+1NC, snap action in deviation (available only with M connector)G 111NO+1NC, slow actionG022NC, slow actionG121NO+2NC, slow actionG222NO+2NC, slow actionH 111NO+1NC, slow action, overlappedH121NO+2NC, slow action, overlapped H222NO+2NC, slow action, overlappedL 111NO+1NC, slow action closer L121NO+2NC, slow action closer L222NO+2NC, slow action closer Other contact blocks on or connector typeNblack PVC cable, IEC 60332 1 (standard)Ggrey PVC cable, CEI 20 22 II Hgrey PUR cable, halogen free Rcable for railway applications (EN 50306 4)MM12 connectorAAMP superseal connectorCheck feasibility using table on page typesilver contacts (standard)

3 Gsilver contacts with 1 m gold coating HousingNAmetal, hole spacing 20 mmNBmetal, hole spacing 25 mmCode structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales heads0without head2head for swivelling lever actuatorsarticleoptionsOutput directionDcable or connector to the rightSconnector at bottomActuators00without actuatorAAshort plungerABplunger ..Connection type2cable, length 2 m (standard)5cable, length 5 mKconnectorOther cable lengths on blockwithout transmission blockW590 transmission block 2LB2LE 2LH2LL2LP 200 adjustable metal swivelling lever with stainless steel rod 3x3x125 mm adjustable metal swivelling lever with stainless steel rod 3x125 mm adjustable metal swivelling lever with fiber glass rod 6x200 mm metal swivelling lever with adjustable flexible rodmetal swivelling lever with porcelain rollmetal head for swivelling lever actuators0CP 0CV 0EB 0EE 0FB 0 GB 0HB0HE0 HHunidirectional roller lever adjustable angled roller lever plunger with M12 threaded head plunger with M12 threaded head with external gasketroller plunger with M12 threaded head plunger with 6 mm ballflexible rod with plastic tip flexible rod flexible rod with needle LOOSE ACTUATORSSee page 139 Ambient temperature 25 C.

4 +80 CT6 40 C .. +80 CRollersstandard rollerR30stainless steel mmR29stainless steel, 13 mmR18technopolymer, 14 mm R23stainless steel, 14 mm R7technopolymer, 18 mm R22technopolymer, 20 mm R24stainless steel, 20 mm R19technopolymer, 22 mm R25technopolymer, 35 mm For Info: Phone: 800-221-0487 Fax: 718-672-63704 Technical dataGeneral Catalogue 2015-2016121 General dataAmbient temperature: See table on page 122 Max. actuation frequency: 3600 operating cycles1/hourMechanical endurance: 20 million operating cycles1 Mounting position: anySafety parameters: B10d: 40,000,00 for NC contactsMechanical interlock, not coded: type 1 according to EN ISO 14119 Vibration resistance (actuators 0BB, 2KB, 2KC, 2KD):5 .. 150 Hz ( m/s2) according to EN 61373 torques for installation: see pages 235 246(1) One operation cycle means two movements, one to close and one to open contacts, as defined in EN 60947 5 housing, baked powder coating, UV resistantVersion with integrated cable, standard length 2 m.

5 Other lengths and special cables on with integrated M12 connector, 5 or 8 polesProtection degree: IP67 according to EN 60529 IP69K according to ISO 20653 (Protect the cables from direct high pressure and high temperature jets)Corrosion resistance in saline mist: 300 hours in NSS according to ISO 9227 Installation for safety applications:Use only switches marked with the symbol aside the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: see internal connections on page 122) as stated in EN 60947-5-1, encl. K, par. 2. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 244. Operate the switch at least with the positive opening force, indicated between brackets below each article, aside the minimum force value. All applicable standards must be conformity with the requirements of:Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and EMC Directive 2004/108 contact opening in conformity with standards:IEC 60947 5 1, EN 60947 5 conformity with standards:IEC 60947 5 1, EN 60947 5 1, IEC 60204 1, EN 60204 1, EN ISO 14119, EN ISO 12100, IEC 60529, EN 60529, ISO 20653, UL 508, CSA Important: Switch off the circuit voltage before disconnecting the connector from the switch.

6 The connector is not suitable for separation of electrical loads. According to EN 60204-1, 2NO+2NC versions with 8-pin M12 and AMP connector can be used only in PELV modular prewired switches NA-NB series If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 235 to page features Metal housing, right or bottom cable output Protection degrees IP67 and IP69K 4 types of integrated cable available Versions with M12 connector for safety applications Versions with AMP connector 14 contact blocks available 36 actuators availablePlease contact our technical service for the list of approved approved by IMQR ated insulation voltage (Ui): 250 VacConventional free air thermal current (Ith): 10 A (1 2 contacts) / 6 A (2 3 contacts) 4 A (4 contacts or 5 pin M12 connector)Protection against short circuits (fuse).

7 10 A (1 2 contacts) / 6 A (2 3 contacts) / 4 A (4 contacts or 5 pin M12 connector), gG typeRated impulse withstand voltage (Uimp): 4 kVProtection degree of the housing: IP67MA terminals (saddle clamps)Pollution degree: 3 Utilization category: AC15 / DC13 (with connector)Operating voltage (Ue): 250 Vac (50 Hz) / 24 Vdc (with connector)Operating current (Ie): 3 A / 2 A (with connector)Forms of the contact element: X, Y, X+Y, X+X, Y+Y, Y+Y+X, X+X+Y, X+X+Y+Y, ZbPositive opening of contacts on contact blocks B01, B11, B02, B12, B21, B22,G01, G11, G02, G12, G21, G22, L01, L11, L02, L12, L21, L22, H01, H11, H02H12, H21, H22In conformity with standards: EN 60947 1, EN 60947 5 1 + A1:2009, fundamental requirements of the Low Voltage Directive 2006/95 and quality marks:IMQ approval: approval: E131787 CCC approval: 2013010305653520 EAC approval: RU C-IT ДМ94.

8 В.01024 Electrical dataRated impulse withstand voltage (Uimp): 4 kV Conditional short circuit current: 1000 A according to EN 60947 5 1 Pollution degree: 3 Please contact our technical service for the list of approved approved by ULUtilization categories R300 pilot duty (28 VA, 125 250 Vdc) B300 pilot duty (360 VA, 120 240 Vac) (1 2 3 cont.) C300 pilot duty (180 VA, 120 240 Vac) (4 cont.)Data of housing type 1, 4X indoor use only , data for versions with 1 2 contacts and type N cable type 1, 4X "indoor use only"In conformity with standard: UL 508, CSA For Info: Phone: 800-221-0487 Fax: 718-672-6370 Switches Unlimited, Technical 800-221-0487 * Fax: Catalogue 2015-2016 Utilization temperatures and electrical dataApprovalsElectrical dataAmbient temperatureextended (-T6)standardUtilization category AC15 Utilization category DC13 Protection against short circuits (fuse)Rated insulation voltage UiThermal current IthCable mobile installationCable flexible installationCable fixed installationCable mobile installationCable flexible installationCable fixed installation250 V120 V24 V250 V125 V24 VCE cULusIMQ EAC CCC4 A4 A4 A2 A10 A 500 Vtype gG250 Vac10 A////+5 C.

9 +70 C 25 C .. +70 CCEEAC CCC4 A4 A4 A2 A10 A 500 Vtype gG250 Vac10 A////+5 C .. +70 C 25 C .. +70 CCE cULusIMQ EAC CCC4 A4 A4 A2 A10 A 500 Vtype gG250 Vac10 A 40 C .. +80 C 40 C .. +80 C 40 C .. +80 C 25 C .. +80 C 25 C .. +80 C 25 C .. +80 CCE IMQEAC CCC4 A4 A4 A2 A6 A 500 Vtype gG250 Vac6 A/ 40 C .. +80 C 40 C .. +80 C/ 25 C +80 C 25 C +80 CCE cULusIMQ EAC CCC4 A4 A4 A2 A6 A 500 Vtype gG250 Vac6 A//// 5 C .. +80 C 25 C .. +80 CCE cULusIMQ EAC CCC4 A4 A4 A2 A6 A 500 Vtype gG250 Vac6 A 30 C .. +80 C 30 C .. +80 C 40 C .. +80 C 25 C .. +80 C 25 C .. +80 C 25 C .. +80 CCE cULusIMQ EAC CCC3 A3 A3 A2 A3 A 500 Vtype gG250 Vac3 A//// 5 C .. +80 C 25 C .. +80 CCE IMQEAC CCC4 A4 A4 A2 A4 A 500 Vtype gG250 Vac4 A/ 40 C +80 C 40 C +80 C/ 25 C +80 C 25 C +80 CCE cULusIMQ EAC CCC4 A4 A4 A2 A4 A 500 Vtype gG250 Vac 300 Vdc4 A 40 C.

10 +80 C 25 C .. +80 CCE cULusEAC CCC//2 A//2 A2 A 500 Vtype gG30 Vac36 Vdc2 ACE cULusEAC CCC4 A4 A4 A2 A10 A 500 Vtype gG250 Vac300 Vdc10 AInternal connections of the cable2NO+2NC1NO+2NC1NO+1NC2NC12345678 black black-white red red-white brown blue violet violet-whiteyellow-green1-2 NC3-4 NC5-6 NO7-8 NO12345678 black black-white red red-white brown blue yellow-green3-4 NC5-6 NC7-8 NO1 412354 1 2 3blackgreybrownblueyellow-green1-2 NC3-4 NO5412354 1 2 3blackgreybrownblueyellow-green1-2 NC3-4 NC5 Internal connections of the connector2NO+2NC1NO+2NC1NO+1NC2NC1NO+1 NCin deviation12345678 nero nero-bianco rosso rosso-bianco marrone blu viola viola-bianco giallo-verde1-2 NC3-4 NC5-6 NO7-8 NO12345678 nero nero-bianco rosso rosso-bianco marrone blu giallo-verde3-4 NC5-6 NC7-8 NO1 412354 1 2 3nerogrigiomarroneblugiallo-verde1-2 NC3-4


Related search queries