Sentinel C-20 Specification SheetPressure Decay Leak Test Instrument Simple, Compact, Economical Single Pressure /Vacuum Decay TestCapability AutoCal with Drift Correction High Flow Valve Option and QuikTestVersatile ConfigurationsSingle Pressure (Vacuum) Decay TestSingle Pressure (Vacuum) Decay Testusing High Cv ValvesHigh Speed, Single Pressure (Vacuum) Decay Test using High Cv ValvesModular Pneumaticswith manifoldmounted valves, calibrated leak standard,and regulator and gage Pressure resolution 24 bit A/Dconverter forfast, repeatable test results (resolution of the transducer full scale)Compact modular enclosurefor easyinstallation (includes all electronics andpneumatics) forbackplane mounting( h x w x d )Monitoring and Programmingvia integraloperator panel available in English orSpanish.

Sentinel C-20 Specification Sheet Pressure Decay Leak Test Instrument Simple, Compact, Economical Single Pressure/Vacuum Decay Test Capability AutoCal with Drift Correction High Flow Valve Option and Quik Test Versatile Configurations Single Pressure (Vacuum) Decay Test

Tags:

  Tests, Sheet, Specification, Pressure, Instruments, Lake, Decay, 20 specification sheet pressure decay leak, 20 specification sheet pressure decay leak test instrument

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Sentinel C-20 Specification Sheet Pressure Decay Leak Test ...

1 Sentinel C-20 Specification SheetPressure Decay Leak Test Instrument Simple, Compact, Economical Single Pressure /Vacuum Decay TestCapability AutoCal with Drift Correction High Flow Valve Option and QuikTestVersatile ConfigurationsSingle Pressure (Vacuum) Decay TestSingle Pressure (Vacuum) Decay Testusing High Cv ValvesHigh Speed, Single Pressure (Vacuum) Decay Test using High Cv ValvesModular Pneumaticswith manifoldmounted valves, calibrated leak standard,and regulator and gage Pressure resolution 24 bit A/Dconverter forfast, repeatable test results (resolution of the transducer full scale)Compact modular enclosurefor easyinstallation (includes all electronics andpneumatics) forbackplane mounting( h x w x d )Monitoring and Programmingvia integraloperator panel available in English orSpanish.

2 Download test and instrumentsetup via Display panelmakes operatorinterface simple, fastand comprehensive VFD displaywith digital test results,test parameters, counters, past testresults (2 lines by 40 character display) Test result lightsfor Test Accept andReject and In-Test Simple Keypadfor direct access toAuto Calibrate, Menu for Part andInstrument configuration, Self Test,Start, Stop, and Counters with test Program Configuration for 4 partsincludes timers, test pressures, reject rates,calibration parameters, Quik test setup, andProcess Drift correction setupInstrument Configurationincludes Leakstandard value, test result display (leak rateor Pressure drop), Pressure range and units(psi or kPa)

3 , Input/Output option selection,Cal method, display language selection, andCommunication Calibrationroutine tests masterproduction part with internal calibrated leakstandard to automatically establish thepressure-loss-over-time to leak raterelationship for the part drift correctionmaintainscalibration accuracy by monitoring andautomatically making incrementaladjustments for changes in temperature andenvironmental Testmonitors the instantaneous in-testresults and ends the testing process early forobvious accept and reject parts saving up to80% of test Test functionsinclude internalpneumatic leak check and Collectionstores the digital test resultsof final leak rate, Quik test leak rate, Pressure loss, part program number, and testresult for 500 via RS232includes testparameters, instrument setup, test results andcounter information at a baud rate of LanguageOperator panel: Specified English orSpanishOperator display: Programmable ininstrument setup as either English orSpanishSimple tooling interfacefor applicationsrequiring one tooling output with nooperator safety requirements, there is a sealoutput option.

4 Standard Start and Stopinputs and Accept and Reject outputs arealso available for interface to aPLC orpushbuttons and integral 3 input/3 output digitalinterface. One input and one output areprogrammable within the Menu commandfor the instrument Inputsinclude Start and Stop plusthe selection of Part Presence or Auto Cal onthe programmable input terminal. Remotepart program selection utilizes a pulse trainsignal via the programmable input Outputsinclude Part Accept andPart Reject plus the selection of SealAdvance, Exhaust, InCycle, or PartProgram Feedback on the programmableoutput FunctionsPressure Decay testing with gage pressuretransducerSinglePressurePneumati cs, Standard Cv(1/8 orifice) valvesPressure range: Vacuum, 15, and 100 psigSinglePressurePneumatics, High Cv(5times higher flow-1/4 orifice) valvesPressure range: Vacuum, 15, and 100 psigSingle Pressure SpeedTest Cycle capability with High Cv valvesPressure range: Vacuum, 15, and 100 psigPressure resolution: of pressurerange Displayed Pressure resolution for filland stabilization.

5 Units Displayed Pressure resolution for unitsPart Program storage 4 part programsCalibration system NIST traceable calibrated leak standardsized to within +5%/-0% of specifiedreject rate with an accuracy of + value. Mounted directly to pneumaticmanifoldCommunication:One way RS232- on front of operator panel forexternal connection 9600 baud, no parity, 8 bits, 1 stop bit,no flow control Includes part setup, instrument setup,counters, and test results Stream of Pressure values during testevery secondsInput/Output Terminals3 inputs and 3 outputs are available via a 12-pin cable connector on the top of theenclosure. The Inputs are sinking andoutputs are sourcing via mechanical include:StartStop/release Programmable optionsPart presence or Auto CalOutputs include:Part AcceptPart Reject Programmable optionsSeal advanceExhaustIn CycleorPart Select FeedbackInstrument Power Requirements 120 VAC amps.

6 24 VDC ampsEnclosure:Nema 12 industrial enclosure, die castaluminumDimensions: W x H x DWeight: 10 lbsAmbient conditions: 5 to 40 C (41 to 109 F)Humidity: 90%non-condensingInstrument Option SelectionTest Capability DesiredSingle Pressure , Pressure Decay LeakRate and Pressure DropFast-fill valves, Single Pressure , Pressure Decay Leak Rate andPressure DropHigh Speed Test, Fast-fill valves,Single Pressure , Pressure Decay LeakRate and Pressure DropTest Pressure rangeVacuum (0 to psiv)0 15 psig0 100 psigPower source for instrument120 VAC24 VDCFace Plate LanguageEnglishSpanishLeak Rate_____Test Pressure_____