Transcription of Series 6800 Pump - Aquatec
1 SPECIFICATIONS:nMOTOR:TYPE:24 VAC, Permanent Magnet,Totally Enclosed, Non-VentilatedLEADS:20 AWG, 6 LONGTEMP. LIMITS:This Motor is Not Equipped with ThermalProtection. For User Safety, OptimalPerformance, and Maximum Motor Life, TheMotor Surface Temperature Should Not Exceed150 F (66 C), as Shown on the Heat Rise CYCLE:See Heat Rise GraphnPUMP DESIGN:3 Chamber Diaphragm Pump, Self Priming, Capable of Being Run DrynTYPICAL APPLICATION:Pre-Filter Water Treatment ( Boost)nMATERIALS:HOUSINGS:NylonVALVES:EP DMDIAPHRAGM:SantopreneFASTENERS:Stainles s SteelnLIQUID TEMPERATURE:170 F (77 C) CERTIFICATIONS:NSF Standard 58nPRIMING CAPABILITIES:nFITTINGS: Aquatec International, Pullman Street, Irvine, CA 92614 Sales: 949-225-2200 Fax.
2 949-225-2222 6800 PumpModel: 68XX-2X03-B221 Flow Range: Open Flow = . LPMAt 80 PSI = . LPM68X068X1 PRIME (FEET)34 COMPLETINGTHEPARTNUMBER:68XX-2X03-B221 Flexible Mounting Plate(Other Types Available)See Performance Data for Recommended By-passPressure and CodeBy-Pass Pressure Relief Control ValveSelect Pumphead Model From Performance Data Chart2 = Open Ports for 1/4 Compression Fitting4 = Push to Connect Ports for 1/4 Tubing5 = Push-to-Connect Ports for 3/8 " COMPRESSIONSTRAIGHT25-0311/4" TUBING1/4" COMPRESSIONELBOW25-0321/4" TUBING3/8" STEMSTRAIGHT25-0291/4" JOHN GUEST PUSH-ON FITTINGWEIGHT.
3 6 DATADISCHARGEPUMPHEAD MODEL RECOMMENDEDPRESSURE 68X0 68X1 BY-PASS PRESSURE(PSI)FLOW (LPM)CURRENT (AMPS)FLOW (LPM)CURRENT (AMPS) MEASURED WITH FLOODED INLET (0 PSI), 70 F (21 C) AMBIENT AND WATER TEMPERATURE, AND VOLT-AGE CONTROLLED AT 24 VAC. POSITIVE INLET PRESSURE WILL INCREASE THE DISCHARGE PRESSURE BY A SIMILARAMOUNT, FOR A GIVEN FLOW. MAXIMUM INLET PRESSURE IS 60 AREA DENOTES CONTINUOUS OPERATION CAPABILITY AT DESIGNATED PRESSURE AND 6800 PumpModel: 68XX-2X03-B221 HEAT RISE608010012014016018020001020304050607 08090100110120 TIME (MINUTES).
4 72 AMPSRECOMMENDEDSHUT-OFF TEMPERATUREAll of the pump models in the Performance Data and Heat Rise charts are in the shaded area, meaning they are capable ofsustaining continual running, at any of the above listed pressures, without shutting down to allow the motor to cool. Toconserve wearing parts, however, the pump should only operate as should be exercised in selecting the proper transformer for this 24 VAC motor. The largest wall mount transformerfrom Aquatec is only rated to .80 amps. Aquatec s table top transformer is rated to amps. By-Pass pressures mustalso be considered when selecting a suitable transformer, in the event the pump is allowed to reach the preset by-pass pres-sure for sustained PERFORMANCE AND HEAT RISE FIGURES ARE APPROXIMATE.
5 ACTUAL VALUES WILL VARY WITH AMBIENT CONDITIONS.