SERVICE DROP CABLE - KINGWIRE Building Wire, …

APPLICATION:DUPLEX: To supply 120 volts aerial SERVICE for temporary SERVICE at construction sites, outdoor or street lighting. For SERVICE at 600 volts or lower at conductor temperatures not to exceed 75 C for polyethylene insulated conductors or 90 C for crosslinked polyethylene (XLP) insulated : To supply power from the utility s lines to the consumer s weatherhead. For SERVICE at 600 volts or less (phase to phase) at a conductor temperature of 75 C maximum for polyethylene insulation or 90 C maximum for crosslinked polyethylene (XLP) insulated : Used to supply 3 phase power, usually from a pole mounted transformer to the user s SERVICE head where connection to the SERVICE entrance CABLE is made.

KINGWIRE Duplex Service Drop - Aluminum Conductor AAC Code Word Phase Conductors Bare Neutral Weight per 1000 (lbs) Rating (AMPS) Size AWG Strand Insulation

Tags:

  Services, Cable, Drop, Service drop cable

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SERVICE DROP CABLE - KINGWIRE Building Wire, …

1 APPLICATION:DUPLEX: To supply 120 volts aerial SERVICE for temporary SERVICE at construction sites, outdoor or street lighting. For SERVICE at 600 volts or lower at conductor temperatures not to exceed 75 C for polyethylene insulated conductors or 90 C for crosslinked polyethylene (XLP) insulated : To supply power from the utility s lines to the consumer s weatherhead. For SERVICE at 600 volts or less (phase to phase) at a conductor temperature of 75 C maximum for polyethylene insulation or 90 C maximum for crosslinked polyethylene (XLP) insulated : Used to supply 3 phase power, usually from a pole mounted transformer to the user s SERVICE head where connection to the SERVICE entrance CABLE is made.

2 To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 C for polyethylene insulated conductors or 90 C for crosslinked polyethylene (XLP) insulated conductors. PRODUCT FEATURES:Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC or drop CABLESTANDARDS:800-453-5464 drop CABLE meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire ANSI/ICEA S-76-474 KINGWIRE Duplex SERVICE drop - Aluminum Conductor AACCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)

3 Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyPeakingese6 Solid4567 , , Duplex SERVICE drop - Aluminum Conductor ACSR - Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolySetter6 Solid4566/11, , , , , , Duplex SERVICE drop - Aluminum Conductor AAAC - Alloy Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyChihuahua6 Solid4567/w1, , , , , , * Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201.

4 Conductor temperature of 90 C for XLP, 75 C for Poly; ambient temperatures of 40 C; emissivity ; 2ft/sec. wind in sun.** To determine current ampacity by conductor size, please consult The National Electric Code, latest edition. The data is approximate and subject to normal manufacturing Triplex SERVICE drop - AAAC-Alloy Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyMinex6 Solid45671, , , , , , , , , , , Triplex SERVICE drop - Aluminum Conductor - AAAC - Alloy Reduced Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)

5 XLPPolyXLPPolyArtemia4 Solid45671, , , , , , , , , Triplex SERVICE drop - Aluminum Conductor - AAC - Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs) , , , , , , ,1461, , Triplex SERVICE drop - Aluminum Conductor - Full Size ACSR MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyPaludina6 Solid4566/11,1901141138570 Voluta67/w4566/11,1901151128570 Whelk4 Solid4546/11,86016316111090 Periwinkle47/w4546/11,86017216911090 Conch27/w4526/12,850262257150115 Neritina1/07/w601/06/14,380420414200115 Cenia1/019/w601/06/14,380414408200115 Runcina2/07/w602/06/15,310519512230180 Triton2/019/w602/06/15,310511505230180 Cherrystone3/07/w603/06/16,6206566432602 05 Mursia3/019/w603/06/16,620633626260205 Razor4/07/w604/06/18,350814799300235 Zuzara4/019/w604/06/18, ,6801,1601.

6 147300290 KINGWIRE Triplex SERVICE drop - Aluminum Conductor - ACSR Reduced Size MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyScallop4 Solid4566/11,19014213911090 Strombus47/w4566/11,19015114811090 Cockle27/w4546/11,860228224150115 Janthina1/07/w6026/12,850367360200155 Ranella1/019/w6026/12,850361356200155 Cavolinia2/07/w6016/13,550452444230180 Clio2/019/w6016/13,550444437230180 Sanddollar3/07/w601/06/14,38057055726020 5 Aega3/019/w601/06/14,380565552260205 Cutlefish4/07/w602/06/15,310706691300235 Cerapus4/019/w602/06/15, ,3501,1351,093380290* Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201.

7 Conductor temperature of 90 C for XLP, 75 C for Poly; ambient temperatures of 40 C; emissivity ; 2ft/sec. wind in sun.** To determine current ampacity by conductor size, please consult The National Electric Code, latest edition. The data is approximate and subject to normal manufacturing tolerances. Quadruplex SERVICE drop - Aluminum Conductor AAC - Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyClydesdale4 Solid454788120820110080 Pinto47/w454788122320710080 Mustang27/w45271,350333312135105 Criollo1/019/w601/071,990529504180135 Percheron2/019/w602/072,510649620205155 Hanovarian3/019/w603/0193,31079976523518 0 Oldenburg4/019/w604/0194, ,1461,5461,519330240 KINGWIRE Quadruplex SERVICE drop - Aluminum Conductor ACSR- Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)

8 XLPPolyXLPPolyMorochuca6 Solid4566/11,1901521477560 Chola67/w4566/11,1901621517560 Morgan4 Solid4546/11,86022622010080 Hackney47/w4546/11,86024122610080 Palomino27/w4526/12,850362342135105 Costena1/019/w601/06/14,380575550180135 Grullo2/019/w602/06/15,310707678205155 Suffolk3/019/w603/06/16,620872838235180 Appaloosa4/019/w604/06/18,3501,0791, ,5801,6131, ,3501,5481,494330240 KINGWIRE Quadruplex SERVICE drop - Aluminum Conductor AAAC-Alloy - Neutral MessengerCode WordPhase ConductorsBare NeutralWeight per 1000 (lbs)Rating (AMPS)Size AWGS trandInsulation Thickness (MLS)Size AWGS trandBreaking Strength (lbs)XLPPolyXLPPolyBay6 Solid45671,1101451407560 French Coach67/w45671,1101551447560 German Coach4 Solid45471,76021420810080 Arabian47/w45471,76022921410080 Belgian27/w45272,800344323135105 Shetland1/019/w601/074,460546521180135 Thouroughbred2/019/w602/075,390670641205 155 Trotter3/019/w603/076,790825791235180 Walking4/019/w604/078,5601,019979270205* Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201.

9 Conductor temperature of 90 C for XLP, 75 C for Poly; ambient temperatures of 40 C; emissivity ; 2ft/sec. wind in sun.** To determine current ampacity by conductor size, please consult The National Electric Code, latest edition. The data is approximate and subject to normal manufacturing tolerances.