Example: dental hygienist

Service Instructions

1 Service Instructions *PH 13 & 14 PACKAGE HEAT PUMPS*PC 13 & 14 PACKAGE COOLINGHORIZONTAL MODELSWITH R-410 ARS6300011r15 April 2016 This manual is to be used by qualified, professionally trained HVAC technicians does not assume any responsibility for property damage or personal injurydue to improper Service procedures or services performed by an unqualified person. 2008 - 2016 goodman Company, INFORMATION .. 4 - 5 PRODUCT IDENTIFICATION - *PC/*PH[13-14]**H41**.. 6 - 9 PCCP101-103 ROOF 10 PCP101-103 DOWNFLOW 10 PCEF101-103 ELBOW AND FLASHING 11 PCE101-103 11 PCMD101-103 DOWNFLOW MANUAL 12 GPHMD101-103 HORIZONTAL MOTORIZED DAMPER WITH DUCT 12 SQRPC SQUARE TO ROUND 13 SQRPCH SQUARE TO ROUND 13 PCFR101-103 EXTERNAL FILTER 14 PRODUCT 15 ELECTRICAL 16 LINE VOLTAGE 17 SYSTEM OPERATION.

GOODMAN® BRAND PRODUCTS TOLL FREE 1-877-254-4729 (U.S. only) email us at: customerservice@goodmanmfg.com fax us at: (713) 856-1821 (Not a technical assistance line for dealers.) Outside the U.S., call 1-713-861-2500. (Not a technical assistance line for dealers.) Your telephone company will bill you for the call. AMANA® BRAND PRODUCTS TOLL FREE

Tags:

  Amana, Goodman

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Service Instructions

1 1 Service Instructions *PH 13 & 14 PACKAGE HEAT PUMPS*PC 13 & 14 PACKAGE COOLINGHORIZONTAL MODELSWITH R-410 ARS6300011r15 April 2016 This manual is to be used by qualified, professionally trained HVAC technicians does not assume any responsibility for property damage or personal injurydue to improper Service procedures or services performed by an unqualified person. 2008 - 2016 goodman Company, INFORMATION .. 4 - 5 PRODUCT IDENTIFICATION - *PC/*PH[13-14]**H41**.. 6 - 9 PCCP101-103 ROOF 10 PCP101-103 DOWNFLOW 10 PCEF101-103 ELBOW AND FLASHING 11 PCE101-103 11 PCMD101-103 DOWNFLOW MANUAL 12 GPHMD101-103 HORIZONTAL MOTORIZED DAMPER WITH DUCT 12 SQRPC SQUARE TO ROUND 13 SQRPCH SQUARE TO ROUND 13 PCFR101-103 EXTERNAL FILTER 14 PRODUCT 15 ELECTRICAL 16 LINE VOLTAGE 17 SYSTEM OPERATION.

2 18*PC/*PH[13-14]**H41**COOLING ..18 COOLING 18 HEATING 18 DEFROST 19 FAN 19 SCHEDULED 22 ONCE A 22 ONCE A 22 TEST 23 COOLING/HEAT PUMP- Service ANALYSIS 23S-1 CHECKING 24S-2 CHECKING 24S-3 CHECKING THERMOSTAT, WIRING, AND 24S-3A Thermostat and Wiring .. 24S-3B Cooling 25S-3C Heating 25S-4 CHECKING TRANSFORMER AND CONTROL 25S-7 CHECKING CONTACTOR AND/OR 25S-8 CHECKING CONTACTOR 26S-9 CHECKING FAN RELAY 26S-11 CHECKING LOSS OF CHARGE 27S-15 CHECKING 27S-15A RESISTANCE 28S-15B CAPACITANCE 28S-16 CHECKING 29S-16A CHECKING FAN AND BLOWER MOTOR WINDINGS (PSC MOTORS).

3 29S-16D CHECKING EEM CHECKING COMPRESSOR 30S-17A RESISTANCE 30S-17B GROUND 30 INDEX3 INDEXS-17D Operation Test .. 31S-18 TESTING CRANKCASE 31S-18A CHECKING CRANKCASE HEATER 31S-21 CHECKING REVERSING VALVE AND 31S-24 TESTING DEFROST 32S-25 TESTING DEFROST 32S-50 CHECKING HEATER LIMIT CONTROL(S).. 32S-52 CHECKING HEATER 32S-100 REFRIGERATION REPAIR 33S-101 LEAK 33S-102 33S-103 34S-104 CHECKING COMPRESSOR 35S-108 35S-109 CHECKING FIXED ORIFICE RESTRICTION 36S-112 CHECKING RESTRICTED LIQUID 37S-113 REFRIGERANT 37S-114 37S-115 COMPRESSOR REVERSING VALVE 40S-200 CHECKING EXTERNAL STATIC 41S-201 CHECKING TEMPERATURE 41 WIRING 42OT18-60A OUTDOOR 42OT18-60A OUTDOOR 43 SINGLE PHASE HKR** HEAT 44 PCE* 45 SPK* - SINGLE POINT WIRING KIT.

4 46 UNIT WIRING 474 Pride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during its lifetime a product may require Service . Products should be serviced only by a qualified Service technicianwho is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testinginstruments and the appropriate Service manual. REVIEW ALL Service INFORMATION IN THE APPROPRIATESERVICE MANUAL BEFORE BEGINNING NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELSWARNINGTHIS UNIT SHOULD NOT BE CONNECTED TO.

5 OR USED IN CONJUNCTION WITH, ANY DEVICES THAT ARE NOT DESIGN CERTIFIED FOR USE WITH THIS UNIT OR HAVE NOT BEENTESTED AND APPROVED BY goodman . SERIOUS PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/OR HAZARDOUS CONDITI ONS MAY RESULTFROM THE USE OF DEVICES THAT HAVE NOT BEEN APPROVED OR CERTIFED BY PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHERFLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS INFORMATIONTo locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased thisproduct.

6 For further assistance, please contact: goodman BRAND PRODUCTSTOLL FREE1-877-254-4729 ( only)email us at: us at: (713) 856-1821(Not a technical assistance line for dealers.)Outside the , call 1-713-861-2500.(Not a technical assistance line for dealers.) Your telephone company will bill you for the BRAND PRODUCTSTOLL FREE1-877-254-4729 ( only)email us at: us at: (713) 856-1821(Not a technical assistance line for dealers.) is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.

7 ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST, Service OR REPAIR (HEREINAFTER, Service ) THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD Service THE EQUIPMENT. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER Service OR Service PROCEDURES. IF YOU Service THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. IN ADDITION, IN JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES TO Service THE EQUIPMENT SPECIFIED IN THIS MANUAL, ONLY LICENSED PERSONNEL SHOULD Service THE EQUIPMENT.

8 IMPROPER INSTALLATION, ADJUSTMENT, SERVICING OR REPAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL, ADJUST, Service OR REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER TRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY OR successful development of hermetically sealed refrig-eration compressors has completely sealed the compressor'smoving parts and electric motor inside a common housing,minimizing refrigerant leaks and the hazards sometimes as-sociated with moving belts, pulleys or to the design of hermetic compressors is amethod whereby electrical current is transmitted to the com-pressor motor through terminal conductors which passthrough the compressor housing wall.

9 These terminals aresealed in a dielectric material which insulates them from thehousing and maintains the pressure tight integrity of the her-metic compressor. The terminals and their dielectric em-bedment are strongly constructed, but are vulnerable to care-less compressor installation or maintenance procedures andequally vulnerable to internal electrical short circuits causedby excessive system REFRIGERANT HANDLINGW hile these items will not cover every conceivable situation, they should serve as a useful either of these instances, an electrical short between theterminal and the compressor housing may result in the lossof integrity between the terminal and its dielectric embed-ment.

10 This loss may cause the terminals to be expelled,thereby venting the vaporous and liquid contents of the com-pressor housing and venting compressor terminal normally presents no dangerto anyone, providing the terminal protective cover is properlyin , however, the terminal protective cover is not properly inplace, a venting terminal may discharge a combination of(a) hot lubricating oil and refrigerant(b) flammable mixture (if system is contaminatedwith air)in a stream of spray which may be dangerous to anyone inthe vicinity. Death or serious bodily injury could no circumstances is a hermetic compressor to be elec-trically energized and/or operated without having the terminalprotective cover properly in Service Section S-17 for proper INFORMATIONWARNINGREFRIGERANTS ARE HEAVIER THAN AIR.