1 RS6612010 August 2014 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman doesnot assume any responsibility for property damage or personal injury due to improper serviceprocedures or services performed by an unqualified 2014 Goodman Company, InstructionsThe material in this manual does not supercede manufacturer's installation and operation " ChassisACVC96/AMVC96 GCVC96/GMVC96 GasFurnacesis a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved. 2 IMPORTANT INFORMATIONP ride and workmanship go into every product to provide our customers with quality products. It is possible, however,that during its lifetime a product may require Service . Products should be serviced only by a qualified Service technicianwho is familiar with the safety procedures required in the repair and who is equipped with the proper tools, parts, testinginstruments and the appropriate Service manual.
2 REVIEW ALL Service INFORMATION IN THE APPROPRIATESERVICE MANUAL BEFORE BEGINNING NOTICES FOR CONSUMERS AND SERVICERSRECOGNIZE SAFETY SYMBOLS, WORDS AND LABELSWARNINGTO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHERFLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OF CONTENTSWARNINGHIGH VOLTAGEDISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAYBE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTYDAMAGE, PERSONAL INJURY OR WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER Service OR Service YOU INSTALL OR PERFORM Service ON THIS UNIT, YOU ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE WHICHMAY RESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR Service HEATING AND AIR CONDITIONING 2 - 5 PRODUCT 6 - 11 - 13 INSTALLATION 14 - 39 SYSTEM 40 - 45 - 50 SYSTEM OPERATION COMFORTNET.
3 51 - 57 - 76 - 77 ACCESSORY WIRING 78 - 793 IMPORTANT INFORMATION Special Warning for Installation of Furnace or Air Handling Units inEnclosed Areas such as Garages, Utility Rooms or Parking AreasCarbon monoxide producing devices (such as an automobile, spaceheater, gas water heater, etc.) should not be operated in enclosed areassuch as unventilated garages, utility rooms or parking areas because ofthe danger of carbon monoxide (CO) poisoning resulting from the exhaustemissions. If a furnace or air handler is installed in an enclosed area suchas a garage, utility room or parking area and a carbon monoxide producingdevice is operated therein, there must be adequate, direct ventilation is necessary to avoid the danger of CO poisoning whichcan occur if a carbon monoxide producing device continues to operate inthe enclosed area. Carbon monoxide emissions can be (re)circulatedthroughout the structure if the furnace or air handler is operating in can cause serious illness including permanent brain damage or locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased thisproduct.
4 For further assistance, please contact:CONSUMER INFORMATION LINE GOODMAN BRAND PRODUCTSTOLL FREE1-877-254-4729 ( only)email us us at: (731) 856-1821(Not a technical assistance line for dealers.)CONSUMER INFORMATION LINEAMANA BRAND PRODUCTSTOLL FREE1-877-254-4729 ( only)email us us at: (731) 856-1821(Not a technical assistance line for dealers.)Outside the , call 1-713-861-2500.(Not a technical assistance line for dealers.) Your telephone company will bill you for the INFORMATIONgas. If you then smell gas, STOP!above on this "B" in the safety informationabove on this label. If you don't smell8. Move the gas control switch or knob9. Replace control access , go to the next or gas Set the thermostat to the desired12. If the appliance will not operate,To Appliance" and call your service5. Replace control access "OFF". Do not the Instructions "To Turn Off Gas4.
5 Move the gas control switch or knob Do not store or use gasoline orother flammable vapors and liquids in the vicinity of thisTO TURN OFF GAS TO APPLIANCE10. Turn on all electric power to theFOR YOUR SAFETYor any other Turn off all electric power to theappliance if Service is to be Set the thermostat to its lowest Remove control access ignition system which4. This appliance is equipped with an3. Turn off all electric power to the2. Set the thermostat to lowest Remove control access to light the burners by Move the gas control switch or knobautomatically lights the burners. Do notto "OFF". "ON".0140F00001 PSWITCH SHOWNIN "ON" POSITIONGAS CONTROLF orce or attempted repair may result inFOR YOUR SAFETY READ BEFORE OPERATING call the fire , personal injury or loss of you cannot reach your gas supplier,a fire or explosion may result causing propertyIf you do not follow these Instructions exactly,which has been under Use only your hand to move the gascontrol switch or knob.
6 Never usetools. If the gas control switch or knobD. Do not use this appliance if any parthas been under water. Immediately calla qualified Service technician to inspectthe appliance and to replace any part ofthe control system and any gas control7. Wait five (5) minutes to clear out anywill not operate, don't try to repair it,call a qualified Service heavier than air and will settle on theImmediately call your supplierthe gas suppliers TO DO IF YOU SMELL GASDo not try to light any not touch any electric switch;do not use any telephone in yourfrom a neighbor's phone. Follow1. STOP! Read the safety informationOPERATING fire or to light the burners by next to the floor because some gasthe appliance area for gas. Be sure toB. BEFORE OPERATING smell aroundautomatically lights the burners. Do notis equipped with an ignition device whichA. This appliance does not have a pilot.
7 Itreproductive product containsfiberglass to causecontains a chemicalFiberglass insulationinstructions and localIf notWARNING:cause cancer, birthdefects or otherin fuel combustionyou to substancesdeath or seriouswhich can causeState of California toare known to theillness and whichaccordance with theand maintained ininstructions, thisproduct could exposemanufacturer'sinstalled, operatedFor outdoorPGB & PGJFor indoor local codes, followcodes. In the absenceCode, ANSI National Fuel Gasinstallation injury orconsult a qualifiedRefer to the user'sinformation manualprovided with thisproperty furnace must beor the gas , Service ormaintenance canWARNING:Improper5 IMPORTANT INFORMATIONCONSIGNES DE SECURITE - LIREAVANT D'ALLUMER L'APPAREILAVERTISSEMENT: Le non-respect des Instructions qui suivent peutentrainer un risque d'incendie ou d'explosion causant des dommages,des blessures ou la Cet appareil comporte pas de veilleuse.
8 Il est muni d'un mecanisme qui allumeautomatiquement le bruleur. N'allumez paz le bruleur Sentir tout autour de l'appariel AVANT D'ALLUMER afin de deceler toute fuite de de sentir tout pres du plancher car certains gaz sont plus lourds que l'airet se deposeront sur le VOUS SENTEZ UNE ODEUR DE GAZ:Ne tentez d'allumer aucun touchez pas aux interrupteurs electriques; n'utiliser aucun telephonedans l'edifice ou vous vous immediatement votre fournisseur de gaz en utilisant le telephoned'un voisin et suivez les Instructions du les pompiers si vous ne parvenez pas a rejoindre votre fournisseurde N'utiliser que votre main pour pousser ou tourner le commande du gaz. N'utilisezjamais d'outils. Si vous ne parvenez pas a pousser ou a tourner la commande, ne tentezpas de la reparer; appelez un reparateur qualifie. Forcer la commande ou essayer de lareparer peut entrainer un risque d'incendie ou d' N'utilisez pas cet appareil si l'une de ses parties a ete dans l'eau.
9 Si cela se produit,demandez immediatement a un reparateur qualifie d'inspecter l'appareil et de remplacertoute piece du systeme de controle et toute commande de gaz ayant ete dans l' DE SERVICE1. UN INSTANT! Lisez d'abord les consignes2. Reglez le thermostat a son point le plus Coupez l'alimentation electrique de l' Cet appareil est muni d'un mecanisme qui allume automatiquement le bruleur. Ne tentez pas d'allumer le bruleur Retirez le panneau d'acces de la Mettez la commande de gaz a la position7. Attendez cinq (5) minutes afin de permettre a tout gaz present d'etre evacue. Si vous sentez une odeur de gaz a ce moment, ARRETEZ! et suivez les consignes de securite donnees au de gaz, passez a l'etape Mettez la commande de gaz a la position en Retablissez l'alimenation electrique de l' Reglez le thermostat a le temperature Si l'appareil ne fonctionne pas, suivez les Instructions intitulees "Arret du gaz" et appelez un reparateur qualifie ou votre fournisseur de DU GAZ1.
10 Reglez le thermostat a son point le plus Coupez l'alimentation electrique de l'appareil si vous devez effectuer un Retirez le panneau d'acces de la Mettez la commande de gaz a la position ARRET ("OFF").5. Remettez le panneau d'acces de la commande en place. de securite ci-dessus. ARRET ("OFF"). paragraphe B ci-dessus. Si vous ne sentez pas MARCHE ("ON").9. Remettez la panneau d'acces de la commande^^^^^^^^^^^^^Commande de"MARCHE"gaz en positionPRODUCT IDENTIFICATION6 The model and manufacturing number are used for positive identification of component parts used in use these numbers when requesting Service or parts TYPEM: Upflow/HorizontalD: Decidated DownflowC: Downflow/HorizontalH: High Air FlowFURNACE TYPEE: Two-Stage/X-13 MotorS: Single-Stage/Multi-SpeedV: Two Stage/ variable -SpeedH: Two Stage Gas Valve -Multi-SpeedAFUE8: 80%9: 90%95: 95%NOMI NAL INPUT040: 40,000 Btuh060: 60,000 Btuh080: 80,000 Btuh100: 100,000 Btuh120: 120,000 BtuhAIRFLOW CAPABILITY@ " ESP3: 12004: 16005: 2000 CABINETWIDTHA: 14"B: 17-1/2"C: 21"D: 24-1/2"ADDITIONALFEATURESN: Nat ural GasX: L o w N O xPRODUCTTYPE:G: GoodmanA: Amana BrandD: Amana Distinctions BrandMAJOR REVISIONA.