Transcription of Shimaden, Temperature and Humidity Control …
1 Series SR70 SHIMADEN DIGITAL CONTROLLER C%RHShimaden, Temperature and Humidity Control SpecialistsMulti-input and multi-range performanceIncludes a new processing system, Expert PID, remarkablyimproved PID Control efficiency; overshoot and undershootare controlled keylock function can avoid erroneous operationresulting from set values or parameter PV bias function can correct errors caused by wide selection of additional functions (optional) isavailable to suit various FEATURES&NRTL /Capproved SPECIFICATIONSD isplayDigital display:7 segments / Measured value (PV) Green LED 4 digits, Set value (SV) Orange LED 4 digitsParameter display:By 7 segment LEDs for PV and SVAction display / colors:3-type LED lamp indication Control output (OUT) / Green Auto tuning (AT) / Green Alarm (AH and AL / HB) / RedDisplay accuracy: ( FS+1 digit) excluding cold junction Temperature compensationaccuracy in the case of the thermocouple input.
2 5% FS for temperatures below 400 C (750 F) of thermocouple accuracy range:23 5 CDisplay resolution:Depends on measuring range ( , 1)Measured value display range:-10~110% of measuring range(-210~680 C for -200~600 C of input)Sampling :By 4 front key switchesSetting range:Same as the measuring range. Refer to Table of Measuring Range of input / measuring range:Thermocouple, and voltage (mV) input types: Multi-input, Multi-range Refer to Table of Measuring Range (V) and current (4~20mA) input types: by code selectionThermocouple:B, R, S, K, E, J, T, N {U, L (DIN 43710)} External resistance: 100 impedance: 500k : Standard feature (up scale)Cold junction Temperature compensation accuracy: 2 C (5~45 C) :JIS Pt100 / JPt100 3-wire typeAmperage: Approx.
3 Wire tolerable resistance: 5 max. / wire (The 3 lead wires should havesame resistance.)Voltage:0~10, 10~50, 0~100mV DC or 0~1, 1~5, 0~10V DCInput impedance: 500k :4~20mA DCReceiving impedance: 250 Sampling bias: unit in case the decimal point is included in the measuring range. If not, 200 filter:0~100 sec. (0 = without filter)Isolation:Insulated between input and output (not insulated between input and system, SV bias and CT input)ControlControl mode:Auto-tuning PID Control / On-Off controlProportional band ( P ):Off, ~ FS (Off setting: On-Off action)Integral time ( I ):1~6000 time ( D ):0~3600 sec. (0 sec. setting: PI action)On - Off hysteresis:1~999 unitProportional cycle:Fixed to 20 sec. during contact output Fixed to 2 sec.
4 During SSR drive voltage outputControl output characteristics:RA / DA selectable (set RA when shipped)Set value function ( SF ):Off (Off = ) and ~ output type / ratingContact output ( Y1 ):SR71: 240V AC 2A / resistive load: / dielectric loadSR72, SR73 and SR74: 240V AC / resistive load: / dielectric loadCurrent output ( I1 ):4~20mA DC / load resistance: 600 drive voltage output ( P1 ):15 3V DC (with load resistance at ) / load current: 20mA maximumVoltage output ( V1 ):0~10V DC / load current: 2mA maximumIsolation:Isolated between Control output and system and inputAlarm outputNumber of alarm points:2 (AH and AL / HB) (for both normal open and common)Alarm Type:Selectable from combinations of the following 9 typesAlarm setting range:Higher limit and lower limit absolute value alarms: Within measuring rangeDeviation value: Higher limit: 0~2000 unit*Lower limit: -1999~0 unit*Alarm action:On - Off actionAlarm action hysteresis:Fixed to of the measuring rangeAlarm output / rating:Contact 1a (common) / 240V AC (resistive load)} assignedHigher limit deviation value + 1.
5 Lower limit deviation value without inhibit actionHigher limit absolute value + 2. lower limit absolute value without inhibit actionHigher limit deviation value + 3. lower limit deviation value with inhibit actionHigher limit absolute value + 4. lower limit absolute value with inhibit actionHigher limit deviation 5. value without inhibit action + heater breakHigher limit absolute 6. value without inhibit action + heater breakHigher limit deviation 7. value with inhibit action + heater breakHigher limit absolute 8. value with inhibit action + heater breakIn case SV is out of themeasuring range, higher andlower limit values of themeasuring range become theaction FUNCTIONS (OPTIONAL)Series SR70 Heater break alarm (for single phase)(Note: This function can be added if the instrument has an alarm option and the Control output is the contact type or theSSR drive voltage type.)
6 In SR71, addition is possible unless it has an SV bias option.)Alarm action:Heater amperage detected by externally attached CT (CT provided). Alarmoutput On upon detection of heater break while Control output is setting range:Off, ~ (Alarm action stops when Off is set.)Setting ~ accuracy:5% FS (when sine wave is 50 Hz)Minimum time foraction confirmation:On time: 500 holding:Selectable between Lock (holding) and Real (no holding)Sampling cycle:2 :Insulated between CT input and Control output (not isolated between CT inputand system and other inputs)Set value bias(Note: In case of SR71, this function can be added unless it has a Heater Break Alarm option.)Setting range:-1999~2000 unitSetting resolution:Same as display resolutionAction input:Non-voltage contact (bias in action when SB terminal is closed)Isolation:Insulated between the SV bias input and the Control output (not isolatedbetween the SV bias and the system and other inputs)OthersData storage:By non-volatile memory (EEPROM)Operating ambient Temperature / Humidity range:-10~50 C / 90% RH max.
7 (no dew condensation)Data storage Temperature :-20~+65 CSupply voltage:100~240V AC 10% (50 / 60 Hz)Power consumption:Approx. 11 VAInput noise eliminating ratio:Normal mode: 60dB min. (50 / 60Hz)Common mode: 130dB min. (50 / 60Hz)Applicable standard:Safety: IEC1010-1 and EN61010-1 EMC: EN61326 Insulation resistance:Between the input / output terminal and the power supply terminal: 500V DC 20M minimumBetween the input / output terminal and the ground terminal: 500V DC 20M minimumDielectric strength:1 min. at 2300V AC between the input / output terminal and the power supply terminals1 min. at 1500V AC between the power supply terminal and the groundterminalProtective structure:Only front panel has simple dust-proof and drip-proof structureMaterial:PPO resin molding (equivalent to UL94V-1)External dimensions:SR71: H48 W48 D110 (panel depth: 100) mmSR72: H72 W72 D110 (panel depth: 100) mmSR73: H96 W96 D110 (panel depth: 100) mmSR74: H96 W48 D110 (panel depth: 100) mmMounting:Push-in panel (one-touch mount)Panel ~ mmPanel cutout:SR71: H45 W45mm, SR72: H68 W68mmSR73: H92 W92mm, SR74: H92 W45mmWeight:SR71: Approx.
8 180g, SR72: Approx. 260gSR73: Approx. 330g, SR74: Approx. 250gSeries SR70 Series SR70 APPLICATION EXAMPLE (SV BIAS)ALARM OUTPUT (OPTIONAL)WIRING EXAMPLENote: 1. The heater break alarm function (optional) can be added when the Control output is of the contact (Y1) or the SSR drive voltage (P1) Fuse: Since the instrument dose not have a built-in fuse, do not forget to install a fuse in the power circuit to be connected to the power fuse should be positioned between the switch or the breaker and the instrument and be attached to the L side of the power Rating: 250V AC / medium lagged or lagged typeUse a fuse which meets the requirements of IEC power supply100-240V AC 50/60Hz: Electro-magnetic switchHigher limit alarmLower limit alarm orhealer break alarmPower supply200V AC50/60 HzCTHeaterThermocoupleSBSV bias no-voltage contact(closed for input)CT+A-BBLSR73, SR74 NGRCOMNONCCOMAHAL Contact output (Y1)SR73, SR74 Operatingpower supplyPAC series(thyristor)PAC series(SSR)Heater4-20mA DCHeater15V DC20mA , SR74141516141516--Operatingpower supplyCurrent output (I1) Control output portion only SSR drive voltage (P1) Control output portion only ++-+-+600 sensorTimerPlant culture tankSet value for target Temperature (SV)SV bias (SB)
9 Bias operationsignal23 C18 C-5 CONOFFDay Night Day NightTHeaterSR73controllerAlarm MethodAlarm Setting RangeActionHigher limit deviation value alarm0~2000 unitLower limit deviation value alarm-1999~0 unitHigher limit absolute value alarmwithin measuring rangeLower limit absolute value alarmwithin measuring rangeONOFFONOFFONOFFONOFFMain settingAlarm settingExternal DimensionsPanel CutoutTerminal Arrangement7272 ENTSHIMADENSR72 OUTATAHAH / HBSVPV11010010100 + + +DC++ 240V 240V AC100-240V AC~50/60Hz11 VACOMNONCOUTPUT4 - 20mA DC0 - 10V DC20mA15V 240V ACLGRN SR73 External DimensionsPanel CutoutTerminal Arrangement(Common)9696 ENTSHIMADENSR73 OUTPVAHAH / HBATSV100110104896 SHIMADENSR74 PVSVENTOUTATAH AH / HB10100110130 + + instruments are installedin colse contact with each number of + 0130 min.
10 (48xN 3)+ 045+ 0+1234567891011121314151617181920-SBCT10 0-240V AC~50/60Hz10 VACOMNONC OUTPUT4-20mA DC0-10V DC20mA15V 240V ACDC++ABB--COM 240V 240V ACLNGR SR74 External DimensionsPanel CutoutTerminal Arrangement4848 ENTSHIMADENSR71 OUTATAHAH / HBSVPV1101001060 + + +++---100-240V AC~50/60Hz11 VADCAGRBBCT/SBCOM 240V 240V AC OUTPUT4-20mA DC0-10V DC20mA15V DC2A240V AC LNUnit : mmUnit : mmUnit : mmUnit : mmSeries SR70SR71SR72SR73 AND SR74 Series SR70 ORDERING INFORMATIONACCESSORIES REQUIRED FOR HEATER BREAK ALARM FUNCTION (COMMON)ITEMSCODESPECIFICATIONSSR71-H48 W48 D110 DIN size digital controller for auto tuning PID controlSERIESSR72-H72 W72 D110 DIN size digital controller for auto tuning PID controlSR73-H96 W96 D110 DIN size digital controller for auto tuning PID controlSR74-H96 W48 D110 DIN size digital controller for auto tuning PID Control Thermocouple B, R, S, K, E, J, T, NValue set at8 Multi input{U, L (DIN43710)}K 0~1200 CINPUT Pt100 / JPt100when shipped Voltage (mV) 0~10, 10~50, 0~100mV DC4 Current (mA) 4~20mA DC Value set at 4~20mA / 0~ when shipped6 Voltage (V)