Example: dental hygienist

Shipboard Cable - Walsin

Shipboard CableContent Cable TypeUnarmored cables Armoredcables Armored & PVC Protective covered cables Page (Rate voltage) High Voltage Power Cable ( ,6/10kV)--- SPYCB, FA-SPYCB SPYCBY, FA-SPYCBY 4 --- TPYC, FA-TPYC TPYCY, FA-TPYCY 6 --- SPYC, FA-SPYC 12 21 YCYPS-AF ,YCYPS --- --- Power & Lighting Cable ( )

High Voltage Power Cable Power & Lighting Cable Control & Signal Cable Telephone and Instrumentation Cable 3 6/10 kV FA-TPYCY Rated Voltage 3.6/6 kV !6/10 kV !

Tags:

  Walsin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Shipboard Cable - Walsin

1 Shipboard CableContent Cable TypeUnarmored cables Armoredcables Armored & PVC Protective covered cables Page (Rate voltage) High Voltage Power Cable ( ,6/10kV)--- SPYCB, FA-SPYCB SPYCBY, FA-SPYCBY 4 --- TPYC, FA-TPYC TPYCY, FA-TPYCY 6 --- SPYC, FA-SPYC 12 21 YCYPS-AF ,YCYPS --- --- Power & Lighting Cable ( )

2 DPY, FA-DPY DPYC, FA-DPYC DPYCY, FA-DPYCY 13 TPY, FA-TPY TPYC, FA-TPYC TPYCY, FA-TPYCY 14 --- DPYCSLA,FA-DPYCSLA DPYCYSLA,FA-DPYCYSLA 18 --- TPYCSLA,FA-TPYCSLA TPYCYSLA,FA-TPYCYSLA 18 FR-DPY, FR-FA-DPY FR-DPYC,FR-FA-DPYC FR-DPYCY, FR-FA-DPYCY 20 FR-TPY, FR-FA-TPY FR-TPYC,FR-FA-TPYC FR-TPYCY, FR-FA-TPYCY 21 Control & Signal Cable (150/250V) MPY, FA-MPY MPYC, FA-MPYC MPYCY, FA-MPYCY 26 --- MPYCSLA,FA-MPYCSLA MPYCYSLA,FA-MPYCYSLA 28 --- MPYC-S, FA-MPYC-S MPYCY-S, FA-MPYCY-S 28 Telephone and InstrumentationCable FR-MPY, FR-FA-MPY FR-MPYC,FR-FA-MPYC FR-MPYCY, FR-FA-MPYCY 32 TTY, FA-TTY TTYC, FA-TTYC TTYCY, FA-TTYCY 36 --- TTYCSLA,FA-TTYCSLA TTYCYSLA.

3 FA-TTYCYSLA 40 TTYC-SLA FA-TTYC-SLA TTYCY-SLA FA-TTYCY-SLA 42 34 noitamrofnI lacinhceT cirtcelE 54 ETACIFITRECC opper condutorMica tapeEPR insulationSuitable fillerSuitable tapePVC sheathGalvanized steel wire braidPVC protective coveringSymbols explanation for ships cables accordance to JIS C3410-2010 Symbols denoting number of cores and principal use FA Flame retardant(IEC 60332-3-22) FFour core for lighting and power FR Fire resistant(IEC 60331 1/2) M Multicore for control and signal FR-FA Flame retardant and Fire resistant TT Telephone and instrumentation S Single core for lighting and power PPortable or flexible D Double core for lighting and power T Three core for lighting and power Symbols denoting constituentsInsulation (1) Outer covering Armouring (2)

4 Protective covering Others PEPrubber YPVCCG alvanized steel wire braidYPVC Protective covering -SIndividual core shield with braid YPVC CB Copper alloy wire braid SLAC ommon shield with Aluminium foil-mylar tape and drain wire -SLAI ndividual pair shield with Aluminium foil-mylar tape and drain wire EEarth wire Notes:(1) For telephone Cable , the insulation symbol is omitted. (2) In the case of copper alloy wire braid, letter B shall be suffixed to letter C. Symbols explanation example for Cable type " kV FR-FA-TPYCY" kV FR-FA-TPYCY Construction of Cable (Example) kV Voltage rate FR-FA Flame retardant and Fire resistant T Three core conductor P EPR Insulation Y PVC sheath C Galvanized steel wire braid Y PVC protective covering 1 High Voltage Power CablePower & Lighting CableControl & Signal CableTelephone andInstrumentation CableHigh Voltage Power CablePower & Lighting CableControl & Signal CableTelephone andInstrumentation Cable3 6/10 kV FA-TPYCY Rated Voltage kV 6/10 kV Power Cable Cable Symbols TPYC , FA-TPYC TPYCY, FA-TPYCY SPYCB , SPYCB SPYCBY, PYCBY Application Standard Design guide JIS C 3410(2010),IEC 60092-350(2008-02), IEC 60092-351(2004-04) IEC 60092-353(2001-04)

5 , IEC 60092-354(2003-06), IEC 60092-359(1999-08) Flame retardant IEC 60332-1& IEC 60332-3-22 Category A (FA-Type) Max. conductor temperature 90 CONSTRUCTION Classification Code Construction Detail Conductor S,T Stranded tinned annealed copper wires as per JIS C 3410. InsulationP EPR as per JIS C 3410,IEC 60092-351 Cabling Insulated conductors shall be cabled. Flame retardant & Non-hygroscopic fillers may be used. Suitable tape(s) may be applied on the cabled core. Sheath Y PVC as per JIS C 3410,IEC 60092-353 Armor C Braid of galvanized steel wires. Coverage density is minimum 90%. CB Braid of copper alloy wire, Coverage density is minimum 90 %.

6 (for single core only) Paint The white paint shall be painted uniformly on the steel wire braid Protective covering Type, paint is dispensable. Protective Covering Y PVC as per JIS C 3410. Outer sheath color : Red Core identification 3 Cores:White, Red, Blue High Voltage Power CablePower & Lighting CableControl & Signal CableTelephone andInstrumentation Cable4 TABLE 1 kV SPYCB kV FA-SPYCB Conductor Radial thickness of insulation Radial thickness of sheath Diam. of metal wire braid armour Nominal overall diam. Tolerance of diam. over sheath & overall diam. Cable weight (Approx.)SizeConstruction mm mm mm mm mm mm kg/km 107 560 167 660 257 795 357 940 5019 1110 7019

7 1380 9519 1710 12037 2010 15037 2330 18537 2890 24061 3590 30061 4330 TABLE 2 kV SPYCBY kV FA-SPYCBY Conductor Radial Thickness of insulation Radial thickness of sheath Diam.

8 Of metal wire braidarmour Radial thickness of protective covering Nominal overall diam. Tolerance of diam. over sheath & overall diam. Cable weight (Approx.)SizeConstruction mm mm mm mm mm mm mm kg/km 107 640 167 755 257 895 357 1050 5019

9 1230 7019 1520 9519 1870 12037 2180 15037 2520 18537 3090 24061 3830 30061 4610 High Voltage Power CablePower & Lighting CableControl & Signal CableTelephone andInstrumentation Cable5 TABLE 3 6/10 kV SPYCB 6/10 kV FA-SPYCB Conductor Radial thickness of insulation Radial thickness of sheath Diam.

10 Of metal wire braid armour Nominal overall diam. Tolerance of diam. over sheath & overall diam. Cable weight (Approx.) SizeConstruction SQ mm mm mm mm mm mm kg/km 167 765 257 910 357 1060 5019 1230 7019