Ultrasonic Transmitters THE Probe . Operating Instructions 03/ 2010 . Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this Manual . Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user's agent.

7ML19985GD62 The Probe ΠINSTRUCTION MANUAL Page 1 mmmmm English Introduction The Probe is an ultrasonic level monitor combining sensor and electronics in a single package.

Tags:

  2010

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Siemens The Probe User Manual - 2010-03 - Lesman

1 Ultrasonic Transmitters THE Probe . Operating Instructions 03/ 2010 . Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this Manual . Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user's agent.

2 All new components are to be provided by Siemens Milltronics Process Instruments Inc. Restrict repair to faulty components only. Do not reuse faulty components. Warning: Cardboard shipping package provides limited humidity and moisture protection. This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications. Note: Always use product in accordance with specifications.

3 Copyright Siemens Milltronics Process Disclaimer of Liability Instruments Inc. 2010 . All Rights Reserved This document is available in bound version and in While we have verified the contents of this electronic version. We encourage users to purchase Manual for agreement with the instrumentation authorized bound manuals, or to view electronic described, variations remain possible. Thus we versions as designed and authored by Siemens cannot guarantee full agreement. The contents Milltronics Process Instruments Inc. Siemens of this Manual are regularly reviewed and Milltronics Process Instruments Inc.

4 Will not be corrections are included in subsequent editions. responsible for the contents of partial or whole Please check the website shown below for the reproductions of either bound or electronic versions. latest Manual revisions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications European Authorized Representative at the following address: Technical Publications Siemens AG. Siemens Milltronics Process Instruments Inc. Industry Sector 1954 Technology Drive, Box 4225 76181 Karlsruhe Peterborough, Ontario, Canada, K9J 7B1 Deutschland Email: For a selection of Siemens Milltronics level measurement manuals, go to: www.

5 Choose Instructions and Manuals under the More Info list. For a selection of Siemens Milltronics weighing manuals, go to: www. Choose Support, and then Manuals / Operating Instructions. Siemens Milltronics Process Instruments Inc. 2010 . Introduction Notes: English This product is intended for use in industrial areas. Operation of this equipment in a residential mmmmm area may cause interference to several frequency based communications. The Probe is to be used only in the manner outlined in this instruction Manual . The Probe is an ultrasonic level monitor combining sensor and electronics in a single package.

6 It is designed to measure liquid levels in closed vessels. The sensor is PVDF or ETFE, allowing The Probe to be used in a wide variety of industries. The optional sanitary version affords quick removal and ease of cleaning as demanded by the food, beverage and pharmaceutical industries. The sensor houses the ultrasonic transducer and temperature sensing element. The Probe emits a series of ultrasonic pulses from the transducer. Each pulse is reflected as an echo from the material and sensed by the transducer. The echo is processed by The Probe using Milltronic's proven `Sonic Intelligence' techniques.

7 Filtering is applied to help discriminate between the true echo from the material, and false echoes from acoustical and electrical noises and agitator blades in motion. The time for the pulse to travel to the material and back is temperature compensated and then converted into distance for display, mA output and relay actuation. Installation Environmental The Probe should be mounted in an area that is within the temperature range specified and that is suitable to the housing rating and materials of construction. The front lid should be accessible to allow programming, wiring and display viewing.

8 It is advisable to keep The Probe away from high voltage or current runs, contactors and SCR control drives. Location Locate The Probe so that The Probe 's sound path it will have a clear sound should not intersect the fill path perpendicular to the path rough walls, seams, liquid surface rungs, etc fill fill sanitary ferrule pipe rungs seams 7ML19985GD62 The Probe INSTRUCTION Manual Page 1. Mounting Note: Mount The Probe so that the face of the sensor is at least 25 cm above the highest anticipated level. English Threaded mmmmm hinged lid 7 mm The Probe is available in three thread types: ( ") 84 mm ( ") max.

9 2" NPT, 2" BSP or PF2. 117 mm ( "). Note: Before inserting The Probe into its cable entry mounting hole, ensure that the threads are of 'knock out'. 279 mm electronics (11"). the same type to avoid damaging The Probe 87 mm threads. ( ") mounting thread 74 mm sensor mounting ( "). thread 53 mm 61 mm ( "). ( ") max. Flange Adapter (optional). optional The Probe flange adapter The Probe can be fitted with the optional 75 mm (3") flange adapter for mating to 3" ANSI, DIN. 65PN10 and JIS 10K3B flanges. Sanitary 7 mm Notes: Mount The Probe so that the face of hinged lid ( ") 84 mm 117 mm ( ") max.

10 The sensor is at least 25 cm above ( "). the highest anticipated level. The sanitary Probe is suitable for chemical clean-in-place cable entry electronics 'knock out' 279 mm applications to 60 C (140 F) only. (11"). Ensure your cleaning chemicals are 87 mm mounting ( ") . compatible with PVDF. thread integral 76 mm sensor sealing ring ( "). 61 mm 53 mm ( ") ( "). max. The Probe 4 Sanitary Ferrule mount The Probe onto the top of the tank's sanitary ferrule secure mating by surrounding clamp the joint with the clamp adjusting tighten adjusting wing nut wing nut ferrule tank 119 mm ( ").