Example: marketing

SIGMA Spectrum Operator's Manual

Operator's Manual SIGMA SPECTR UM infusion PUMP WITH. MASTER DR UG LIBRAR Y. 35700 BAX2. Pump Operating Software Version For use with Master Drug Library Version 41018v0800 Rev. B. December 10, 2014. Manual 41018v0800 SIGMA Spectrum infusion System Revision B Operator's Manual 2014 Copyright Baxter Healthcare Corporation 711 Park Avenue Medina, New York 14103. T F ii SIGMA Spectrum infusion System Pump Operating Software Version Operator's Manual For Use With MDL Version TABLE OF CONTENTS. Introduction and Safety .. 1. Intended Use .. 1. Related Documents .. 1. Regulatory Information .. 1. Trademark Information .. 1. Contacting Baxter Technical Support .. 1.

Infusion Pump with Master Drug Library is intended to be used by trained healthcare professionals. Related Documents The following documents also pertain to the SIGMA Spectrum Infusion System:

Tags:

  Pumps, Infusion, Infusion pump

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SIGMA Spectrum Operator's Manual

1 Operator's Manual SIGMA SPECTR UM infusion PUMP WITH. MASTER DR UG LIBRAR Y. 35700 BAX2. Pump Operating Software Version For use with Master Drug Library Version 41018v0800 Rev. B. December 10, 2014. Manual 41018v0800 SIGMA Spectrum infusion System Revision B Operator's Manual 2014 Copyright Baxter Healthcare Corporation 711 Park Avenue Medina, New York 14103. T F ii SIGMA Spectrum infusion System Pump Operating Software Version Operator's Manual For Use With MDL Version TABLE OF CONTENTS. Introduction and Safety .. 1. Intended Use .. 1. Related Documents .. 1. Regulatory Information .. 1. Trademark Information .. 1. Contacting Baxter Technical Support .. 1.

2 Conventions .. 2. Summary of Warnings and Cautions .. 2. General Warnings .. 2. Procedural Warnings .. 4. Procedural Cautions .. 11. System Components .. 17. SIGMA Spectrum infusion System Illustrations .. 17. SIGMA Spectrum infusion Pump, Front View .. 18. SIGMA Spectrum infusion Pump, Front View with Door Open .. 18. SIGMA Spectrum infusion Pump, Rear View Without Battery .. 19. SIGMA Spectrum infusion Pump, Rear View with Battery Installed .. 19. SIGMA Spectrum infusion Pump Display Features .. 20. Pump Icons .. 21. Keys Used to Program and Operate the Pump .. 22. Soft Keys .. 22. Hard Keys .. 23. Symbols .. 24. Labels .. 25. Battery Compatibility .. 27.

3 Battery Replacement .. 27. Battery Maintenance .. 27. Servicing SIGMA Spectrum infusion System .. 28. Setting Up the Pump .. 29. Unpacking the Pump .. 29. Connecting and Disconnecting the AC Power Adaptor .. 30. Charging the Battery .. 31. Table of Contents iii Manual 41018v0800 SIGMA Spectrum infusion System Revision B Operator's Manual Configuring User Options ..32. Alarm Settings .. 33. Display Settings .. 34. View Information .. 34. Preparing the Pump and IV Sets ..36. Mounting the Pump on an IV Pole ..36. Preparing and Priming an IV Set ..36. Loading an IV Set ..37. Unloading an IV Set ..44. Secondary infusion Setup ..46. Programming the Pump ..47. Pump Safety Features.

4 47. infusion Programming Options ..48. infusion Delivery Modes ..49. Activating a Drug Library on a Pump with a Wireless Battery Module ..49. Dose Error Reduction System (DERS) Programming ..50. Secondary infusion ..58. Clearing the Secondary infusion to Return to the Primary infusion .. 63. Secondary Callback .. 64. Loading Dose ..67. Bolus ..69. Multi-Step ..70. Cyclic TPN ..74. Dose Change or Rate Change of a Continuous infusion ..76. Changing the VTBI Without Stopping the Pump ..78. Delayed Run ..79. Confirming Weight and BSA ..80. Amount/Time infusion ..80. Priming Volume .. 87. Line Flush .. 88. Changing the Rate of an Amount/Time infusion .. 93. BASIC Mode.

5 94. Placing the Pump in STANDBY (Hold) ..98. Keypad Lock ..100. iv Table of Contents SIGMA Spectrum infusion System Pump Operating Software Version Operator's Manual For Use With MDL Version Alarms .. 102. Silencing an Alarm Tone .. 103. Clearing an Alarm .. 103. Clinician Alert Tone .. 104. Alarm Messages .. 105. Troubleshooting Alarm Causes .. 114. Managing Bolus before Occlusion (Downstream) Release .. 114. Battery Warning Levels .. 115. Low Battery .. 115. Very Low Battery .. 116. Battery Depleted .. 116. Cleaning and Storage .. 117. Compatible Cleaners .. 117. Cleaning the Pump .. 118. Cleaning the Battery Module .. 120. Cleaning the AC Power Adaptor.

6 120. Cleaning the Pole Clamp .. 121. Pump Handling, Transport and Storage .. 122. Compatible IV Sets .. 123. Compatible Baxter IV Sets .. 123. Compatible Baxter IV Sets WARNINGS .. 127. Accessories .. 130. Tandem Carrier .. 130. Three-Pump Carriers .. 130. Multi-Pole .. 131. Double Rotating Pole Clamp Assembly .. 132. Appendix A: Specifications .. 133. Master Drug Library (MDL) .. 133. Drug Library Transfer .. 133. Standard Gravity IV Sets .. 133. Standards .. 134. Pump Specifications .. 134. Appendix B: Flow Rate Accuracy .. 140. Table of Contents v Manual 41018v0800 SIGMA Spectrum infusion System Revision B Operator's Manual Effect of Fluid Container Height.

7 140. Effect of Back Pressure ..140. Flow Profile ..142. Standard Conditions .. 143. Baxter Administration Set Accuracy Graphs ..144. Appendix C: Bolus Accuracy ..149. Appendix D: Downstream Occlusion..150. Time to Occlusion Alarm ..150. Bolus Volume ..150. Appendix E: Electromagnetic Compatibility ..151. Emissions ..151. Immunity ESD, transient/burst, voltage disparity and magnetic field ..152. Immunity Conducted and Radiated ..154. Immunity Separation Distances ..156. Appendix F: Low / Very Low Battery Alarm Instructions..157. Low Battery Alarm Instructions ..158. Very Low Battery Alarm Instructions ..159. Appendix G: Default Settings ..160. Factory Settings for Pump Software.

8 160. BASIC Configurations .. 161. Glossary ..163. Index ..171. vi Table of Contents SIGMA Spectrum infusion System Pump Operating Software Version Operator's Manual For Use With MDL Version INTRODUCTION AND SAFETY. Intended Use The SIGMA Spectrum infusion Pump with Master Drug Library is intended to be used for the controlled administration of fluids. These may include pharmaceutical drugs, blood, blood products and mixtures of required patient therapy. The intended routes of administration consist of the following clinically accepted routes: intravenous, arterial, subcutaneous, epidural or irrigation of fluid space. The SIGMA Spectrum infusion Pump with Master Drug Library is intended to be used in conjunction with legally marketed and compatible intravenous administration sets and medications provided by the user.

9 The SIGMA Spectrum infusion Pump with Master Drug Library is suitable for a variety of patient care environments such as, but not limited to, hospitals and outpatient care areas. The SIGMA Spectrum infusion Pump with Master Drug Library is intended to reduce operator interaction through guided programming, thereby helping to reduce errors. The SIGMA Spectrum infusion Pump with Master Drug Library is intended to be used by trained healthcare professionals. Related Documents The following documents also pertain to the SIGMA Spectrum infusion System: SIGMA Spectrum infusion System Service Manual (P/N 41019v0800). SIGMA Spectrum infusion System Master Drug Library User Manual (P/N 41020v080).

10 Regulatory Information Tested and conforms to UL STD 60601-1. Certified to CAN/CSA STD NO Trademark Information Product names or trademarks appearing in this Manual are the property of their respective owners. Contacting Baxter Technical Support Contact Baxter for all technical support and service information at: Telephone: E-mail: Introduction and Safety 1. Manual 41018v0800 SIGMA Spectrum infusion System Revision B Operator's Manual Conventions WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury or property damage.


Related search queries