Example: biology

目 錄 - signal.com.tw

1 / 53 Ver: Chapter 1 1-1 .. 03 1-2 Code ID Table List .. 04 1-3 Data Output Format .. 04 1-4 .. 05 Chapter 2 System Settings .. 07 Output Interfaces .. 07 Code ID Selection .. 08 Buzzer Settings .. 08 Select Keyboard Type .. 09 Select KBD Wedge Character Table Type .. 09 Capital Lock Settings .. 10 Digits Transmission .. 10 RS232 Baud Rate .. 11 RS232 Parity .. 11 RS232 Data Bit .. 12 RS232 Flow Control Settings .. 12 RS232 ACK/NAK 12 RS232 Flow Control Waiting Time Settings .. 13 RS232 STX/ETX .. 13 Scan Mode .. 14 Read Redundancy .. 15 Termination Character Transmission .. 15 Prefix/Suffix Settings .. 16 Inter-Block Delay .. 17 Inter-Character Delay .. 17 Length Code .. 18 Enable/Disable All Readable Barcode .. 18 Enable/Disable All Barcodes Length .. 19~20 Negative Barcode Setting .. 20 .. 21 Interleaved 25 .. 22 Standard/Full ASCII Code 39 .. 23 Code 128.

3 / 53 Ver: 1.08 Chapter 1 簡 介 1-1: 操作及安裝 本條碼閱讀機為近貼至中距離讀取範圍,掃描時必需觸發條碼機上之Button,待紅色光

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 目 錄 - signal.com.tw

1 1 / 53 Ver: Chapter 1 1-1 .. 03 1-2 Code ID Table List .. 04 1-3 Data Output Format .. 04 1-4 .. 05 Chapter 2 System Settings .. 07 Output Interfaces .. 07 Code ID Selection .. 08 Buzzer Settings .. 08 Select Keyboard Type .. 09 Select KBD Wedge Character Table Type .. 09 Capital Lock Settings .. 10 Digits Transmission .. 10 RS232 Baud Rate .. 11 RS232 Parity .. 11 RS232 Data Bit .. 12 RS232 Flow Control Settings .. 12 RS232 ACK/NAK 12 RS232 Flow Control Waiting Time Settings .. 13 RS232 STX/ETX .. 13 Scan Mode .. 14 Read Redundancy .. 15 Termination Character Transmission .. 15 Prefix/Suffix Settings .. 16 Inter-Block Delay .. 17 Inter-Character Delay .. 17 Length Code .. 18 Enable/Disable All Readable Barcode .. 18 Enable/Disable All Barcodes Length .. 19~20 Negative Barcode Setting .. 20 .. 21 Interleaved 25 .. 22 Standard/Full ASCII Code 39 .. 23 Code 128.

2 24 2 / 53 Ver: EAN 128 .. 25 Codabar .. 26 Italy Pharmacode (Code 32) .. 27 Code 93 .. 27 China Postal Code .. 28 Industrial 25 .. 29 Matrix 25 .. 30 UPCA .. 31 UPCE .. 32 EAN13 .. 33 EAN8 .. 34 DataBar(RSS)-14 .. 35 DataBar(RSS)-Limited .. 35 DataBar(RSS)-Expanded .. 36 Chapter 3 Activate Editing Format .. 38 Exclusive Data Editing .. 38 Define Data Criteria Applicable Code Type .. 39 Define Data Criteria Data Length .. 40 Define Data Criteria Matching String & Location of Matching String .. 40 Divide Data into Fields Total Number of Fields .. 41 Divide Data into Fields Field-1 setting .. 42 Divide Data into Fields Field-2 setting .. 42 Divide Data into Fields Field-3 setting .. 43 Divide Data into Fields Field-4 setting .. 43 Divide Data into Fields Field-5 setting .. 43 Divide Data into Fields Additional Fields .. 44 Field Transmission Sequence (12 Fields can output at the same time).

3 45 A : ASCII .. 46 B : ASCII .. 47 C : Function Code (for PC PS2 Keyboard) .. 51 D : KBD Wedge Character Table .. 52 E : RS232 Character Table .. 53 3 / 53 Ver: Chapter 1 1-1: Button ( ) , a. b. Cable c. ( Buzzer .. ) d. ( / / .. ) e. ( / Editing Format .. ) f. Keyboard Wedge a. (PC) b. PS2( ) (PC) (PC) PS2( ) c. (PC) d. (Word ) RS232 a. DB9( ) (PC) DC 5V/500mA DC b. c. (PC) Com Pore Baud DC 5V/500mA HID USB a.

4 USB( ) (PC) b. (PC) ( HID Keyboard) c. (Word ) 4 / 53 Ver: 1-2: Code ID Table List Default ID (AIM) Code ID Barcode Type Default ID AIM ID Code 39 C M Y ]A0 Codabar N X ]F0 Interleave 25 I Z ]I0 China Postal Code D ]X0 Industrial 25 H ]S0 Matriax 25 U ]X0 UPCA A ]E0 EAN13 A F ]E0 EAN8 B FF ]E4 UPCE C E ]E0 Code 128 K ]C0 Code 93 L ]G0 Full ASCII Code 39 O ]A0 Italy Pharmacode P ]X0 EAN 128 W ]C1 DataBar-14 R ]e0 DataBar-Limited S ]e0 DataBar-Expanded T ]e0 1-3: Data Output Format : STX Prefix Code Code Length Code ID Barcode Data Suffix Code ETX 5 / 53 Ver: 1-4: , Example: HID USB Step1: Step2: Step3: Step4: 6 / 53 Ver: Example: Code 128 17 Step1: Step2: Step3: Step4: 1 Step5: 7 Step6: Step7: 2 , : 1 01 9 09 15 15 7 / 53 Ver: Chapter 2 _____ Restore Default Settings: Firmware Version: Enable Power Saving: , 60 Sec , Button Disable Power Saving.

5 System Settings Restore Default Settings Firmware Version Enable Power Saving Disable Power Saving Keyboard less Power Saving _____ IBM PC-AT , RS232 ,HID USB Output Interfaces PC AT RS 232 Keyboard less HID USB , Cable _____ 8 / 53 Ver: _____ Clear All Code ID Settings: Code ID Select AIM ID: ID Select User Defined ID: ID Select ID Set 1~4: ID UPCE/EAN13/EAN8/Interleave 25/Code 39/Codabar Code ID Selection Clear All Code ID Settings ID Set 1(C/A/B/I/M/N) ID Set 2(E/F/FF/I/M/N) ID Set 3(E/A/B/I/C/N) ID Set 4(C/A/B/Z/Y/X) Select AIM ID Select User Defined ID _____ Buzzer Disable: Buzzer Buzzer Frequency KHZ: Buzzer HZ Buzzer Frequency KHZ: Buzzer HZ Buzzer Frequency KHZ: Buzzer HZ Buzzer Settings Buzzer Disable Hz Hz Hz _____ 9 / 53 Ver: _____ , , Select Keyboard Type Alt Key Mode PCAT (US) PCAT (French) PCAT (German) PCAT (Italy) PCAT (Swiss) PCAT (Japanese) PCAT (UK) PCAT (Spanish) , , _____ PC-AT Keyboard Less HID-USB , ASCII D E Select KBD Wedge Character Table Type Type 1 Type 2 _____ 10 / 53 Ver: _____ Auto Detection: Caps Lock , Caps Lock Capital Lock Off: , Caps Lock Capital Lock On: , Caps Lock Fixed Lower Case.

6 Caps Lock , Caps Lock Fixed Upper Case: Caps Lock , Caps Lock Capital Lock Settings Auto Detection Capital Lock Off Capital Lock On Fixed Lower Case Fixed Upper Case _____ Alphanumeric Key: Numeric Key: Digits Transmission Alphanumeric Key Numeric Key _____ 11 / 53 Ver: _____ RS232 Baud Rate 1200 ~ 115200, RS232 Baud Rate 1200 bps 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps _____ Even: 1 0 Parity Bit, 1 Odd: 1 0 Parity Bit, 1 Mark: 1 Parity Bit Space: 0 Parity Bit No Parity: RS232 Parity Even Odd Mark Space No Parity _____ 12 / 53 Ver: _____ 7 Bits: 7 Bits 8 Bits: 8 Bits RS232 Data Bit 7 Bits 8 Bits _____ No Flow Control (No handshake): RTS/CTS Data Ready (RTS signal will be activated after each good read): RTS Pin Hi, Lo Scanner Ready (RTS signal will activate upon powering on): RTS Pin Power On Hi RS232 Flow Control Settings No Flow Control Data Ready Scanner Ready _____ , ACK( ) NAK( ) , NAK Disable ACK/NAK Transmission: ACK/NAK Enable ACK/NAK Transmission: ACK/NAK RS232 ACK/NAK Transmission Disable Enable _____ 13 / 53 Ver: _____ Waiting Time Flow Control, ACK/NAK Transmission Unlimited.

7 RS232 Flow Control Waiting Time Settings 1 sec 5 sec 15 sec Unlimited Unlimited , , _____ STX( )/ETX( ) Disable STX/ETX: STX/ETX Enable STX/ETX: STX/ETX RS232 STX/ETX Disable Enable _____ 14 / 53 Ver: _____ Test mode: , Alternate mode: Button , Button Button Continuous with flashing mode: , , Auto Scan mode: Button , Continuous mode: , , Continous Auto Off mode: Button , , Auto Off mode: Button , Scan Mode Test Alternate Continuous with flashing Auto Scan Continuous Auto Off Continuous Auto Off _____ 15 / 53 Ver: _____ , , Read Redundancy No Redundancy 1 Time 2 Times 3 Times 4 Times 5 Times , _____ CR (Carriage Return): CR+LF (like Enter): LF (Line Feed): Disable: Termination Character Transmission CR CR+LF (Enter) LF Disable _____ 16 / 53 Ver: _____ Enable Prefix: Disable Prefix: Enable Suffix: Disable Suffix: Prefix code: ( 1 ~ 8 ) Clear Prefix code.

8 Suffix code ( 1 ~ 8 ) Clear Suffix code: Prefix/Suffix Settings Enable Prefix Disable Prefix Enable Suffix Disable Suffix Prefix code (max 8 digits) Clear Prefix code Suffix code (max 8 digits) Clear Suffix code _____ 17 / 53 Ver: _____ Inter-Block Delay None 10 ms 50 ms 100 ms 500 ms 1 sec 3 sec 5 sec _____ Inter-Character Delay None 1 ms 2 ms 5 ms 10 ms 30 ms 50 ms 100 ms _____ 18 / 53 Ver: _____ 2 Ex: = 1234567890 10 Output = 101234567890 Length Code Disable Enable _____ Enable All Readable Barcodes: Disable All Readable Barcodes: , Manual Enable/Disable All Readable Barcodes Enable All Readable Barcodes Disable All Readable Barcodes _____ 19 / 53 Ver.

9 _____ Enable/Disable All Barcodes Length All Code Length Enable All Code Length Disable Code 39 Enable Code 39 Disable Codabar Enable Codabar Disable Interleave 25 Enable Interleave 25 Disable China Postal Code Enable China Postal Code Disable Industrial 25 Code Enable Industrial 25 Code Disable Matriax 25 Code Enable Matriax 25 Code Disable UPCA Enable UPCA Disable EAN13 Enable EAN13 Disable EAN8 Enable EAN8 Disable UPCE Enable UPCE Disable Code 128 Enable Code 128 Disable _____ 20 / 53 Ver: _____ Enable/Disable All Barcodes Length Code 93 Enable Code 93 Disable Full ASCII Code 39 Enable Full ASCII Code 39 Disable Italy Pharmacode Enable Italy Pharmacode Disable EAN 128 Enable EAN 128 Disable DataBar-14 Enable Databar-14 Disable DataBar-Limited Enable DataBar-Limited Disable DataBar-Expanded Enable DataBar-Expanded Disable PDF417 Enable PDF417 Disable _____ Barcode Scanner Negative Barcode Setting Disable Enable _____ 21 / 53 Ver: : Disable: Enable: Checksum Verification and Transmission: Check Digit Checksum Verification and no Transmission: Check Digit Checksum no Verification: Check Digit Enable Start/Stop Transmission: & Disable Start/Stop Transmission.

10 & Min Length (01)/[10]: ,( ) [ ] Max Length (60)/[50]: ,( ) [ ] Set User Defined ID: Code ID, 1 2 Clear User Define ID: Code ID Enable Addon 2: UPC/EAN 2 Enable Addon 5: UPC/EAN 5 Disable Addon 2: UPC/EAN 5 Disable Addon 5: UPC/EAN 5 Disable No Addon: UPC/EAN , UPC/EAN Code Enable No Addon: UPC/EAN , UPC/EAN Code , , UPC/EAN ( ..) Enable Addon Space: Disable Addon Space: EN(Enable) 1st digit Transmission: UPC/EAN DS(Disable) 1st digit Transmission: UPC/EAN EN(Enable) Checksum Transmission: DS(Disable) Checksum Transmission: EN(Enable) Prefix Transmission: RSS Code AI DS(Disable) Prefix Transmission: RSS Code AI 22 / 53 Ver: _____ First digit ignored: , (Last Digit) Last digit ignored: , (First Digit) No ignored.


Related search queries