Transcription of SIMATIC TP 177 MICRO - Simatic | Accusine | Efector
1 Page558 Mar 2008 Siemens ITSSIMATIC TP 177 MICROO verview TouchPanel for operator control and monitoring of small machines and plants Low-cost starter device in the touch panel class with graphics capability and all thebasicfunctions required for simple tasks Pixel-graphics " STN touch screen (analog/resistive),Bluemode(4 levels) Specially for SIMATIC S7-200:Communication with the PLC takes place via the integrated interface (point-to-pointconnection) Connection to the PLC over MPI or PROFIBUSDP cable The SIMATIC TP177micro is the successor to the SIMATIC TP070/TP 170micro TouchPanelsBenefits Can even be used where installation space is restricted thanks to vertical installation Fast configuring and start-up Service-friendly thanks to maintenance-free design and the long service life of the backlighting Graphics library is available complete with ready-to-use display objects Can be used worldwide: 32 languages can be configured (including Asiatic and Cyrillic character sets) Up to 5 languages are selectable onlinePage559 Mar 2008 Siemens ITSA pplicationTP177micro Touch Panels can be used wherever small machines and systems are controlled and monitored locally in production, process and building automation alike.
2 They are used in all types of sectors and TP177micro has been designed specifically for use with the SIMATIC S7-200. With fast response times, it isalso ideal for jog with TP 070/TP 170micro Same mountingcutoutas the TP 070/TP STN display, CCFL1)backlit,Bluemode(4 levels) ResistiveanalogTouch Compact design with small installation depth Rugged plastic housing The front is resistant to various oils, greases and standard detergents Numeric system keyboard for decimal, binary and hexadecimal numberformats On-screen alphanumeric keyboard Plug-in terminals for connecting a 24 V DC power supply RS 485 interface for connection of the MPI cable or the PPI adaptor1)ColdCathodeFluorescenceLamps Page560 Mar 2008 Siemens ITSF unction Input/output fieldsfordisplaying and changing process parameters Buttonsfordirect triggering of functions and actions. Up to 16 functions can be configured simultaneously onbuttons Graphicscanbe used as icons instead of text to "label" function keys or buttons.
3 They can also be used asbackground displays (wallpaper).Inthe configuration tool, a library is available containing extensive graphics anda wide variety of objects. All editors with an OLE interface can be used as graphics editors (such asPaintShop,Designer or CorelDraw). Vectorgraphics Simplegeometric basic forms (line, circle and rectangle) can be created direct in the configuringtool Predefinedtexts forlabelingfunction keys, process images and process values in any charactersize Bars for the graphical display of dynamic values Changing languages 5 online languages, 32 configuration languages incl. Asian and Cyrillic character sets User administration (security) Authentication using password Signalingsystem Discrete alarms Analogmessages Freely definable message classes ( , status/fault messages) for definition of acknowledgment responseand display of message events Message history Help texts for process images, messages and variables Arithmetic functions Limit value monitoring for reliable process control of inputs and outputs Indicator light for machine and plant status indication Template concept Creation of picture templates (picture elements configured in the template appear in everyimage)Page561 Mar 2008 Siemens ITS User-friendly maintenance and configuration thanks to.
4 Backup and restoration of configuration, operating system and firmware on a PC usingProSave Configuration download serially via RS485 Individual contrast setting and calibration Clean screen No batteries are necessaryConfiguringSIMATICWinCCflexible MICRO , Compact, Standard or Advanced engineering software Version 2004 SP1 and higherplus HSP is used for more information about engineering software, see HMI software/engineering software PC/PPI adapter cable is needed to download the TP 177micro can be connected to all SIMATIC S7-200-CPUs using the standard MPI bus cables or PROFIBUSDP cables (integration into networks possible).Note:For further information see "System interfaces"Page562 Mar 2008 Siemens ITSTP 177micro: Installation cutout (W x H) in mm: 198 x 142 More informationAdditional information is available in the Internet under: you need a specific modification or option for the products described here? Then look up "Customizedproducts", where you will find information about additional sector-specific products that can be ordered as well asabout options for customer-specific modification and drawingsTechnical specificationsPage563 Mar 2008 Siemens "DisplaytypeSTN,4bluelevelsResolution(pi xels) Resolution(WxHinpixel)320x240 Backlighting MTBF backlighting(at25 C)about50000hoursControlelementsControle lementsTouchscreenFunctionkeys,programma blenoneKeyboardfonts Systemkeys0 Touchoperation TouchscreenAnalog, specificationsPage564 Mar 2008 Siemens ITSM emoryTypeFlashUsablememoryforuserdata256 KBusablememoryforuserdataTimeofdayClock TypeSoftwareclock,nobatterybackupInterfa cesInterfaces1xRS485( )AmbientconditionsStorage/transporttempe rature Transport,storage-20 Cto+60 CRelativehumidity +/-35 DegreeandclassofprotectionFrontIP65,NEMA 4x(wheninstalled)RearIP20 Standards,approvals,certificatesCertific ationsCE,GL,ABS,BV,DNV,LRS, ,UL,CSA,cULus,EX-Zone2(inVorbereitung)
5 ,EX-Zone22(inVorbereitung),C-TICK,NEMA4x Page565 Mar 2008 Siemens EXzone2 Yes EXzone22 YesOperatingsystemsOperatingsystemLINUXC onfigurationConfigurationsoftware ConfigurationtoolWinCCflexibleMicroVersi on2004SP1,HSPorhigher(tobeorderedseparat ely)LanguagesOnlinelanguages Numberofonline/runtimelanguages5 FunctionalityunderWinCCflexibleLibraries YesPage566 Mar 2008 Siemens ITST askplannerYesStatus/controlNotpossibleWi thalarmloggingsystem( ) Numberofmessages500 BitmessagesYes AnalogmessagesYesNumberofprocessimages Processimages250 Variables250 LimitvaluesYes MultiplexingYesImageelements Textobjects500textelements GraphicsobjectBitmaps,icons,icon(full-sc reen),vectorgraphics dynamicobjectsDiagrams,bargraphsLists Textlists150 Graphicslist100 Security Numberofusergroups1 Numberofusers1 PasswordsexportableYesPage567 Mar 2008 Siemens ITSD atacarriersupport MultiMediaCardNoTransfer(upload/download ) TransferofconfigurationserialProcesscoup ling ConnectiontocontrollerforS7-200,seesecti onon"Systeminterfaces"Expandability/open ness OpenPlatformProgramNoDimensionsFrontofen closure(WxH)