1 Doc. No. : C3500-E05A. Smart Pressure Transmitter for Differential / High Static / Gauge / Absolute Pressure Measurement MODEL. APT3500. Best performance High Accuracy Five-year stability under Actual process conditions Duon System Co.,Ltd. Autrol , Autrol are trade mark of Smart Transmitter brand series to measure Pressure , Temperature and Level, which is manufactured & owned by DUON System Co., Ltd(hereafter DUON) since 1989. Autrol , Autrol series also provide services of electric appliance installation, repair of electric, magnetic measuring instruments, electric appliance repair, repair of instruments and appliances for measuring and testing, repair of computer hardware, repair of electronic application machines and apparatus, repair of instruments and appliances for rotating, repair of electric power distribution machines and apparatus, repair of control machines and apparatus, computer hardware maintenance and administration, computer hardware installation.
2 APT3500-Differential and high accuracy Pressure Transmitter APT3100-Differential Pressure Transmitter , APT3200-Gauge & Absolute Pressure Transmitter , APT2100-Temperature Transmitter , AI100-Field Indicator. APT3500. Smart Pressure Transmitter Standard SST Housing High Static Pressure Description of Product Function The APT3500 Smart Pressure Transmitter is a micro processor- Flexible Sensor Input : DP, HS, GP, AP. based high performance Transmitter , which has flexible Various Output : 4 ~20mA , Digital Signals Pressure calibration and output, automatic compensation Setting Various Parameters : Zero/Span, Trim, Unit, Fail-mode, etc. of ambient temperature and process variable, configuration Self Diagnostic Function : Sensor, Memory A/D Converter, of various parameters, communication with HART protocol. Power, etc The application is very various, as measuring liquid, gas or Digital Communication with HART protocol steam flow as well as Pressure and liquid level by application Explosion-proof Approval & Intrinsic Safety Approval : ATEX, FM, FMCanada, KCs, etc.
3 Method. All data of sensor is to be input, modified and stored Marine Certificate: ABS, LR, BR, DNV. in EEPROM. Functional Block Diagram Sensor Part MCU Part 4~20mA. A/D Conversion Microprocessor DAC. Input Sensor Value Engineering Units EEPROM Re-range (Zero / Span). Sensor Trimming HART. Zero Point Adjustment DA Trimming HART Protocol Damping / Filtering with Host Sensor Transfer function High Low LCD Engineering Mode Pressure Pressure Diagnostics Self Compensation User-Selectable Input Communications LCD Display DP/GP. Configuration Data Measuring Range * Subject to change without notice 2. Doc. No. : C3500-E05A. Features Transfer Function Self-Compensation Superior Performance Self-Diagnosis and Others High Reference Accuracy : of Calibrated Span CPU & Analog Module Fault Detection for range 1(DP & GP). Communication Error of Span Fail-mode Handling For spans less than 4:1, LCD Indication accuracy = [ x (URL/span)] % of span Temperature Measurement of Sensor Module for range 2 (DP & GP).
4 Of Span For spans less than 10:1, accuracy = [ + x (URL/span)] % Function for ranges 3 ~ 5 (DP & GP & HS) Range and Sensor Limits of Span Refer to Table 1. For spans less than 5:1, Zero and Span Adjustment Limits accuracy = [ + x (URL/span)] %. Zero and span values can be set anywhere within the for DP6 & GP6 & HS7 & AP 3~5. range limits stated in Table 1.(Page 9). of Span Span must be greater than or equal to the minimum span For spans less than 10:1, stated in Table 1.(Page 9). accuracy = [ + x (URL/span)] %. Long-Term Stability ( URL for 5year) Output (Analog Current and Digital Data). Smart Pressure Transmitter . High Rangeability (100 : 1)(for the range 3~6) LCD Display & ENG Mode Two wire 4~20mA. Flexibility user-configurable for linear or square root output, Data Configuration with HART Configurator digital process value superimposed on 4~20mA signal, Zero Point Adjustment available to any host that conforms to the HART protocol Reliability Power Supply & Load Requirement Continuous Self-Diagnostic Function External power supply required.
5 Automatic Ambient Temperature Compensation * 250 ohm load-- Vdc Fail-mode Process Function * up to a 550 ohm load -- 24 Vdc EEPROM Write Protection Max. Loop Resistance = ( E - 12 ) / CE EMC Conformity Standards (E = Power Supply Voltage). (IEC 61000-4 Series). Voltage Range : 12 to 45 Vdc Transmitter Description Voltage Rating : 24 Vdc 30%. Loop Load ATP3500 Pressure Transmitter can be easily configured from 0 ~ 1500 ohm -- Operation any host that support the HART protocol. 250 ~ 550 ohm -- HART Communications Basic Setup EMC Conformity Standards Operational Parameters. IEC 61000-4 Series 4~20mA Points (Zero/Span) Failure Mode Engineering Units Fail High : Current mA. Damping Time : ~ 60 sec Fail Low : Current mA. Tag : 8 alphanumeric characters Storage Temperature Descriptor : 16 characters -40 to 85 (without condensing). Message : 32 characters. Date : day/month/year Process Temperature Limits (Range codes and approval codes may effect limits).
6 Calibration and Trimming -40 to 120 ( -104 to 248 ). Lower/Upper Range (zero/span). Sensor Zero Trimming Zero Point Adjustment DAC Output Trimming Duon System Co.,Ltd. 02_03. DUON SYSTEM 3. Function Smart Pressure Transmitter Isolation Change main parameter by Button Input/output isolated to 500 Vrms (707 Vdc) Change Unit Working Pressure Limits (silicone oil) Change Upper range value Model D & G 0 ~ 5 MPa - # 1 Change Lower range value 0 ~ 13 MPa - # 2 Change the Damping Second 0 ~ 25 MPa - # 3~6 Select the Decimal Place Model HS 0 ~ 32 MPa - # 3~5 Zero Trim 0 ~ 75 MPa - # 7 Zero Adjustment Model AP 0 ~ MPa - # 3. 0 ~ MPa - # 4. 0 ~ MPa - # 5. Hydrostatic Test Pressure Model D & G 8 MPa - # 1. 20 MPa - # 2. 38 MPa - # 3 ~ 6. Model HS 48 MPa - # 3~5. 60 MPa - # 7. Model AP 0 ~ MPa - # 3. 0 ~ MPa - # 4. 0 ~ MPa - # 5. Burst Pressure Model D & G 69 MPa - # 1 ~ 6. Model HS 132 MPa - # 3~5.
7 80 MPa - # 7. Model AP MPa - # 3 Moving within Menu : Zero 4 MPa - # 4 Moving to below Menu : Span 7 MPa - # 5 Moving Top Menu : Zero+Span 5 Digit LCD. Express all Pressure unit and flow unit. Use 5 digit. Select decimal place (0 to 4). PV, % and mA value indicate on LCD rotationally & automatically. User define unit function 4. Doc. No. : C3500-E05A. Button Menu tree Button Menu tree Zero Zero NORMAL (3sec). Zero (3sec). Zero Span Span (3sec). Span (3sec). Span Zero Span Span Zero Trim CANCEL. (3sec) (3sec). Zero Zero Span SAVE. Zero + span Span Span Span (3sec). Menu 1 Trim 11 Z-TRIM Zero Trim Zero Zero Span Span 12 Z-ADJ Zero Adjustment Zero Zero Span Span 13 LOOP-T Loop Test Zero --PREV. Span CANCEL. Zero Zero SAVE. Span Span Span 2 Setup 21 UNIT Change Unit Zero Zero Span Span 22 U-RNG Change Upper Range Value Zero Smart Pressure Transmitter . Span Span 23 L-RNG Change Lower Range Value Zero Span Span Zero 24 DAMP Damping Second Zero Span Span 25 T-FUNC Select Transfer Function Zero Span Span 26 LOWCUT Select Lowcut & Cut rate Zero --PREV.
8 Span CANCEL. Zero Zero SAVE. Span Span Span 3 LCD 31 LCD-MD Change LCD Mode Zero Zero Span Span 32 DEC-PL Decimal Place Zero CANCEL. Zero Zero SAVE. Span Span Span Zero Zero 33 ENG-MD 331 EN-URV Change Engineering URV. Zero Zero Span Span 332 EN-LRV Change Engineering LRV. Zero Span Span 333 E-UNIT Change Engineering Unit Zero Span Span 331 E-TRF Select Engineering Zero Transfer Function --PREV. Span --PREV. Span CANCEL. Zero Zero SAVE. Span Span Span 4 DEVICE 41 B-LOCK Select Button Lock Zero Zero Span Span 42 M-RST Master Reset Zero Zero Span Span 43 P-ADDR Change HART Polling Address Zero --PREV. Span All state - zero + span EXIT. DUON SYSTEM 5. Physical Specifications Smart Pressure Transmitter Wetted Materials Electrical connections Isolating Diaphragms 316L SST, Monel, 1/2-14 NPT conduit with M4 Screw Terminals Tantalum, HAST-C Process Connections Drain/Vent Valves 316 SST, HAST-C 1/4-18 NPT on inch ( mm) centers Flanges and Adapters 316 SST(ASTMCF8M), HAST-C on flanges for Standard O-ring Viton, PTFE 1/2-14 NPT on Process Adapter (option).
9 Non-wetted materials * Refer to drawing in the last page Fill Fluid Silicone oil or Inert fill Weight Bolts 304 SST kg ( Standard - excluding options ). Electronics Housing Aluminum or 316L SST (Option) 5kg (SST Housing- excluding options). Flameproof and Waterproof (IP67). Cover O-ring Buna-N. Paint Epoxy-Polyester or Polyuret Mounting Bracket 304 SST with U-bolt (304 SST). for 2-inch pipe Nameplate 304 SST. Exploded drawing of APT3500. Nameplate Span and Zero Adjustments AUT. ROL . Electronics Housing Terminal Board Terminal Block Main Board Digital Indicator Cover O-ring Cover AU. TR. OL.. Housing Rotation Set Screw Certification Plate Sensor Module Process O-ring Flange Bolt Standard Flange Flange Adapter Drain/Vent Valve 6. Doc. No. : C3500-E05A. Hazardous Location Certifications (option). KCs Explosive-proof K1 Code : ATEX Certification E2 Code : Type : Flameproof * Intrinsic Safety: Ex ia IIC T5 or T4.
10 (Ex d IIC T6, IP67 ( -20 C Tamb +60 C )) Operating Temperature : For T5: -400C to +400C. Certificate No. : 12-AV2BO-0741 For T4: -400C to +700C. Power Supply : ~ 45 Vdc, 4 ~ 20mA, Ui=30V, Ii=130mA, Pi= , Ci=40nF, Li=104 H. Process Temperature : +80 C. ATEX Certificate No.: Baseefa17 ATEX0003X. ATEX Approvals E1 Code : IECEx Certificate No.: IECEx BAS Type : ATEX Explosion-proof Certification ATEX Certification No. : DNV 14 ATEX 5433X. Standards : EN 60079-0 : 2012 EN 60079-1: 2007. Operating Temperature: -200C Tamb +600C. Ex II 2 G Ex d IIC , IP66/67. Vcd = ~ 45 Vdc, 4~20mA. KCs Intrinsic Safety Certification K2 Code : FM and FMc Certification F1 & F2 Code : * Some certificates are on pending for approval. Please ask us before order. Smart Pressure Transmitter . Connection Diagram of Signal, Power, HHT for Transmitter Field Control Room Local test or - + Remote Indicator (Low impedance).