Example: air traffic controller

SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA

PCTVAir-conditioningFridgeWashing machineAppliances420-00288-01 MPPT 2 KVA- 3 KVA SOLAR inverter /CHARGERSOLAR inverter /CHARGERT able Of ContentsABOUT THIS MANUAL ..1 Purpose .. 1 Scope .. 1 SAFETY INSTRUCTIONS..1 INTRODUCTION.. 2 Features ..2 Basic System Architecture ..2 Product Overview ..3 INSTALLATION..4 Unpacking and Inspection ..4 Preparation ..4 Mounting the Unit ..4 Battery Connection ..5 AC Input/Output Connection ..7 PV Connection ..8 Final Assembly ..9 Communication Dry Contact Signal ..10 OPERATION..11 Power ON/OFF ..11 Operation and Display Panel ..11 LCD Display Icons ..12 LCD Setting ..14 Fault Reference Code ..19 Warning Indicator ..21 Operating Mode Description ..22 Display Setting ..23 SPECIFICATIONS..24 Table 1 Line Mode Specifications ..24 Table 2 inverter Mode Specifications.

This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner. Figure 1 Hybrid Power System INVERTER MODEL 2024/3024 Charging algorithm for Lithium battery Joint Utility and Solar Charging Max Charging Current D ef a ut Ch rgi ng t 80Amp 60Amp

Tags:

  Solar, Conditioners, Air conditioners, Charger, Inverter, Solar inverter charger

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA

1 PCTVAir-conditioningFridgeWashing machineAppliances420-00288-01 MPPT 2 KVA- 3 KVA SOLAR inverter /CHARGERSOLAR inverter /CHARGERT able Of ContentsABOUT THIS MANUAL ..1 Purpose .. 1 Scope .. 1 SAFETY INSTRUCTIONS..1 INTRODUCTION.. 2 Features ..2 Basic System Architecture ..2 Product Overview ..3 INSTALLATION..4 Unpacking and Inspection ..4 Preparation ..4 Mounting the Unit ..4 Battery Connection ..5 AC Input/Output Connection ..7 PV Connection ..8 Final Assembly ..9 Communication Dry Contact Signal ..10 OPERATION..11 Power ON/OFF ..11 Operation and Display Panel ..11 LCD Display Icons ..12 LCD Setting ..14 Fault Reference Code ..19 Warning Indicator ..21 Operating Mode Description ..22 Display Setting ..23 SPECIFICATIONS..24 Table 1 Line Mode Specifications ..24 Table 2 inverter Mode Specifications.

2 25 Table 3 Charge Mode Specifications ..26 Table 4 General Specifications ..27 TROUBLE SHOOTING..28 Appendix: Approximate Back-up Time Table..29 Appendix: Approximate Back-up Time TableModelLoad (VA)Backup Time @ 24 Vdc 100Ah (min)Backup Time @ 24 Vdc 200Ah (min)2 KVA2004006008001000120014001600180020007 6633519813911295816255501610766503339269 2271761401251123 KVA3006009001200150018002100240027003000 4492221249568564835312811005253032271641 26108947467 Note: Backup time depends on the quality of the battery, age of battery and type of battery. Specifications of batteries may vary depending on different THIS MANUALP urpose This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future manual provides safety and installation guidelines as well as information on tools and wiring.

3 SAFETY INSTRUCTIONS WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference. 1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual. 2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.

4 5. CAUTION Only qualified personnel can install this device with battery. 6. NEVER charge a frozen For optimum operation of this INVERTER/CHARGER , please follow required spec to select appropriate cable size. It s very important to correctly operate this Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion. 9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the Fuses (4 pieces of 40A, 32 VDC for 2 KVA and 6 pieces of 40A,32 VDC for 3 KVA) are provided as over-current protection for the battery GROUNDING INSTRUCTIONS -This INVERTER/CHARGER should be connected to a permanent grounded wiring system.

5 Be sure to comply with local requirements and regulation to install this NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits. 13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this INVERTER/CHARGER back to local dealer or service center for maintenance. -1--28-TROUBLE SHOOTINGP roblemLCD/LED/BuzzerExplanation/Possible causeWhat to doUnit shuts down automatically during startup and buzzer will be active for 3 seconds and then complete battery voltage is too low. (< )1. Re-charge Replace response after power The battery voltage is far too low. (< )2. Battery polarity is connected Check if batteries and the wiring are connected Re-charge Replace exist but the unit works in battery voltage is displayed as 0 on the LCD and green LED is protector is LED is quality of AC power.

6 (Shore or Generator)Check if AC breaker is tripped and AC wiring is connected Check if AC wires are too thin and/or too Check if generator (if applied) is working well or check if input voltage range setting is correct. (Appliance Wide)When the unit is turned on, internal relay is switched on and off display and LED are is if battery wires are connected beeps continuously and red LED is code 07 Fault code 05 Fault code 02 Fault code 03 Fault code 01 Fault code 06/58 Fault code 08/09/53/57 Fault code 51 Fault code 52 Fault code 55 Fault code 56 Battery is not connected well or fuse is the battery is connectedwell, please return to repair the unit, if the error happens again, please return to repair voltage is voltage is too current or abnormal .( inverter voltage below than 202 Vac or is higher than 253 Vac)1.

7 Reduce the connected Return to repair centerFan components to repair centerReplace the battery voltage is too if spec and quantity of batteries are meet to repair is over charged. Internal temperature of inverter component is over whether the air flow of the unit is blocked or whether the ambient temperature is too short if wiring is connected well and remove abnormal load. Reduce the connected load by switching off some error. The inverter is overload 110%and time is is a multi-function INVERTER/CHARGER , combining functions of inverter , SOLAR charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/ SOLAR charger priority, and acceptable input voltage based on different applications.

8 Features Pure sine wave inverter Configurable input voltage range for home appliances and personal computers via LCD setting Configurable battery charging current based on applications via LCD setting Configurable AC/ SOLAR charger priority via LCD setting Compatible to mains voltage or generator power Auto restart while AC is recovering Overload/ Over temperature/ short circuit protection Smart battery charger design for optimized battery performance Cold start functionBasic System ArchitectureThe following illustration shows basic application for this INVERTER/CHARGER . It also includes following devices to have a complete running system: Generator or Utility. PV modules (option)Consult with your system integrator for other possible system architectures depending on your inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

9 Figure 1 Hybrid Power SystemINVERTER MODEL2024/3024 Charging algorithm forLithium batteryJoint Utility and SOLAR Charging Max Charging CurrentDefault Charging Current80 Amp60 AmpTable 4 General SpecificationsINVERTER MODELS afety CertificationOperating Temperature RangeStorage temperatureDimension (D*W*H), mmNet Weight, kgCE0 C to 55 C-15 C~ 60 C272x 355 x LCD display2. Status indicator3. Discharging/Charging indicator4. Fault indicator5. Function buttons6. Power on/off switch7. AC input8. AC output9. PV input10. Battery input11. Circuit breaker12. RS-485 communication port13. USB15. Dry ContactNOTE: For parallel model installation and Operation ,please check separate parallel installation guide for the details. -3-Product Overview2 KVA-3 KVA single model1513-26-Table 3 Charge Mode SpecificationsUtility Charging ModeCharging Current@Nominal Input VoltageAbsorptionVoltageAGM / Gel/LEADB atteryFlooded BatteryAGM / Gel/LEADB atteryFlooded BatteryAGM / Gel/LEADB atteryFlooded BatteryRefloatVoltageFloatVoltageChargin g Algorithm3-Step(Flooded Battery, AGM/Gel Battery), 4-Step(LI) SOLAR Charging Mode2024/3024 inverter MODELC harging Current (MPPT)System DC VoltageOperating Voltage Array Open Circuit VoltageStandby Power ConsumptionBattery Voltage AccuracyPV Voltage AccuracyCharging AlgorithmCharging algorithm forlead acid battery60 Amp24 Vdc 30-130 Vdc145 Vdc2W+ +/-2V3-Step(Flooded Battery, AGM/Gel Battery),4-Step(LI)20 MODEL-3-Bulk40 AmpINSTALLATIONU npacking and InspectionBefore installation, please inspect the unit.

10 Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1 User manual x 1 Communication cable x 1 USB cable x 1 Software CD X 1 PreparationBefore connecting all wirings, please take off bottom cover by removing two screws as shown below. Mounting the UnitConsider the following points before selecting where to install: Do not mount the inverter on flammable construction materials. Mount on a solid surface Install this inverter at eye level in order to allow the LCD display to be read at all times. For proper air circulation to dissipate heat, allow a clearance of approx. 200 mm to the side and approx. 300 mm above and below the unit. The ambient temperature should be between 0 C and 55 C to ensure optimal operation.


Related search queries