Transcription of SOLID Transducers and Transmitters - Overview - …
1 SOLID Transducers and Transmitters - OverviewSPM Instrument AB Box 504 SE-645 25 Str ngn s Sweden Technical data are subject to change without +46 152 22500 Fax +46 152 15075 ISO 9001 certified. Copyright SPM 2007-11 TD-260 BAll SOLID Transducers and Transmitters are internally isolated. The vibration Transducers have a temperature range of 40 to +120 C ( 40 to +248 F), whereas the 4 20 mA Transmitters operate in 40 to +85 C ( 40 to +185 F).Article rangeSensitivityCompatible with TD sheetSLD 121 AM8 SMB2 1000 mV/m/s2 VMM, VMR, MG4TD-200 SLD 121 BM82-pin2 1000 mV/m/s2 VMM, VMR, MG4TD-255 SLD 121 EUNF 1/4"SMB2 1000 mV/m/s2 VMM, VMR, MG4TD-200 SLD 121 FUNF 1/4"2 - pin2 1000 mV/m/s2 VMM, VMR.
2 MG4TD-255 SLD 122 AM8 SMB2 5000 Hz 4 mV/m/s2MG4TD-187 SLD 122 BM82-pin2 5000 Hz 4 mV/m/s2MG4TD-201 SLD 122 EUNF 1/4"SMB2 5000 Hz 4 mV/m/s2MG4TD-187 SLD 122 FUNF 1/4"2 - pin2 5000 Hz 4 mV/m/s2MG4TD-201 SLD 144 BM82 - pin2 10 000 Hz 10 mV/m/s2 Leonova, VCMTD-203 SLD 144 FUNF 1/4"2 - pin2 10 000 Hz 10 mV/m/s2 Leonova, VCMTD-203 SLD 243 BExM82 - pin2 10 000 Hz 5 mV/m/s2 Leonova, VCMTD-208 SLD 243 FExUNF 1/4"2 - pin2 10 000 Hz 5 mV/m/s2 Leonova, VCMTD-208 SLD 244 BExM82 - pin2 10 000 Hz 10 mV/m/s2 Leonova, VCMTD-215 SLD 244 FExUNF 1/4"2 - pin2 10 000 Hz 10 mV/m/s2 Leonova, VCMTD-215 Article / CableFrequency rangeMeasuring rangeTD sheetSLD722 CM8 Integrated cable, 3 m *2 1000 Hz0 mm/sTD-263 SLD722 GUNF 1/4"Integrated cable, 3 m *2 1000 Hz0 in/sTD-263 SLD 723 CM8 Integrated cable, 3 m *2 1000 Hz0 25 mm/sTD-205 SLD 723 GUNF 1/4"Integrated cable, 3 m *2 1000 Hz0 1 in/sTD-205 SLD 724 CM8 Integrated cable.
3 3 m *2 1000 Hz0 50 mm/sTD-269 SLD 724 GUNF 1/4"Integrated cable, 3 m *2 1000 Hz0 2 in/sTD-269 SLD 733 CM8 Integrated cable, 3 m *10 1000 Hz0 25 mm/sTD-256 SLD 733 GUNF 1/4"Integrated cable, 3 m *10 1000 Hz0 1 in/sTD-256 SLD 823 CExM8 Integrated cable, 3 m *2 1000 Hz0 25 mm/sTD-253 SLD 823 GExUNF 1/4"Integrated cable, 3 m *2 1000 Hz0 1 in/sTD-253 SLD 833 CExM8 Integrated cable, 3 m *10 1000 Hz0 25 mm/sTD-254 SLD 833 GExUNF 1/4"Integrated cable, 3 m *10 1000 Hz0 1 in/sTD-254 The frequency range is specified for the transducer when permanently installed.
4 The measuring results will be affected at higher frequencies when using a magnetic : Ex approved Transducers must be used together with transducer interface SPM 15226 or Ex approved zener barrier when used in explosive environment.* Standard cable length is 3 meters, but optional lengths may be ordered ( ex. SLDXXXX -L, L = length in meters, max. 30 m). Note: Ex approved Transmitters must be connected through a barrier when used in explosive mA Vibration TransmittersVibration TransducersArticle for protection tube TD sheet14990 SMBIP67 Stainless steelNoTD-24815164 SMBIP67 Stainless steelYesTD-261151682-pinEx, IP67 CompositeYesTD-21715388 SMBIP67 CompositeYesTD-258 Cable Plugs for Vibration Transducers