Distribution System MCBs, RCCBs, Distribution Boards Keeping you protected Warranty Policy : Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of 18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However, MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard Distribution boards. The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printed on the goods.

Distribution System MCBs, RCCBs, Distribution Boards Keeping you protected REGIONAL OFFICES NORTH BRANCH OFFICES New Delhi GE India Industrial Pvt. Ltd.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SOUTH Distribution System - GE Industrial

1 Distribution System MCBs, RCCBs, Distribution Boards Keeping you protected Warranty Policy : Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of 18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However, MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard Distribution boards. The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printed on the goods.

2 Excise duty is not applicable on Guardline MCB, however applicable on RCCBs and DBs. About GE Energy - Industrial Solutions GE Energy - Industrial Solutions, India offers innovative solutions to meet customer needs in Power & Protection. The company has a pan India presence, with 4 regional offices, 9 branch offices and one manufacturing plant. GE Energy, offers solutions to customers in several segments that include power sector, core infrastructure like marine establishments, airports, highways, heavy & light industries, IT & ITES infrastructure, healthcare, commercial and residential segments. Contents Guardline A6 Miniature Circuit Breakers Safetrip B10 Residual Current Circuit Breakers Safeline C14 Distribution Boards Dimensions & Diagrams Guardline Miniature Circuit Breakers Keeping you guarded Salient Features Technical Details Conforms to IS8828:96/IEC60898-1 Rated Current(In) : , 1A, 2A, 3A, 4A, 6A, 10A, 16A, to 63A, 10kA 20A, 25A, 32A, 40A, 50A, 63A.

3 Trip free mechanism Number of Poles : 1 Pole, 2 Pole, 3 Pole and 4 Pole Disconnection with positive contact Breaking Capacity : 10kA. Low watt loss Energy saving Rated Voltage : 240/415V AC. Touch proof terminals IP20 Insulation Voltage : 500V AC. High grade engineering plastic housing Frequency : 50/60Hz ON-OFF flag indication Tripping Characteristics* : C, D. Captive terminal screws Operating Temp Range : -250C to +550C. Compatibility with all DBs Mounting Arrangement : Snap on fixing, 35mm DIN Channel Isolators : 40/63A in 2 Pole, 3 Pole and 4 Pole Higher ratings on request *B series on request Tripping Characterstics Curve Type - B, C & D. 10000. 5000. 3600. Limit Specified in IS: 8828-1996/IEC-60898-1-2002. Lower Limit as per Standard In : Rated Current Upper Limit as per Standard B Type - to 63A. 1000. C Type - to 63A.

4 D Type - to 63A. Reference Calibration Temp. 40 Co 100. Time in Seconds 10. 1. -B-Type- -C-Type- -D-Type- 1 2 3 5 10 14 20 28 50. Multiple of Rated Current A7. Guardline Ordering Codes Current Rating Ordering Ordering Standard (A) Type C Type D Pack Qty Single Pole GLCSP00 GLDSP00 12. 1 GLCSP01 GLDSP01 12. 2 GLCSP02 GLDSP02 12. 3 GLCSP03 GLDSP03 12. 4 GLCSP04 GLDSP04 12. 6 GLCSP06 GLDSP06 12. 10 GLCSP10 GLDSP10 12. 16 GLCSP16 GLDSP16 12. 20 GLCSP20 GLDSP20 12. 25 GLCSP25 GLDSP25 12. 32 GLCSP32 GLDSP32 12. 40 GLCSP40 GLDSP40 12. 50 GLCSP50 GLDSP50 12. 63 GLCSP63 GLDSP63 12. Double Pole GLCDP00 GLDDP00 6. 1 GLCDP01 GLDDP01 6. 2 GLCDP02 GLDDP02 6. 3 GLCDP03 GLDDP03 6. 4 GLCDP04 GLDDP04 6. 6 GLCDP06 GLDDP06 6. 10 GLCDP10 GLDDP10 6. 16 GLCDP16 GLDDP16 6. 20 GLCDP20 GLDDP20 6. 25 GLCDP25 GLDDP25 6. 32 GLCDP32 GLDDP32 6. 40 GLCDP40 GLDDP40 6.

5 50 GLCDP50 GLDDP50 6. 63 GLCDP63 GLDDP63 6. Triple Pole GLCTP00 GLDTP00 4. 1 GLCTP01 GLDTP01 4. 2 GLCTP02 GLDTP02 4. 3 GLCTP03 GLDTP03 4. A8. Current Rating Ordering Ordering Standard (A) Type C Type D Pack Qty 4 GLCTP04 GLDTP04 4. 6 GLCTP06 GLDTP06 4. 10 GLCTP10 GLDTP10 4. 16 GLCTP16 GLDTP16 4. 20 GLCTP20 GLDTP20 4. 25 GLCTP25 GLDTP25 4. 32 GLCTP32 GLDTP32 4. 40 GLCTP40 GLDTP40 4. 50 GLCTP50 GLDTP50 4. 63 GLCTP63 GLDTP63 4. Four Pole GLCFP00 GLDFP00 3. 1 GLCFP01 GLDFP01 3. 2 GLCFP02 GLDFP02 3. 3 GLCFP03 GLDFP03 3. 4 GLCFP04 GLDFP04 3. 6 GLCFP06 GLDFP06 3. 10 GLCFP10 GLDFP10 3. 16 GLCFP16 GLDFP16 3. 20 GLCFP20 GLDFP20 3. 25 GLCFP25 GLDFP25 3. 32 GLCFP32 GLDFP32 3. 40 GLCFP40 GLDFP40 3. 50 GLCFP50 GLDFP50 3. 63 GLCFP63 GLDFP63 3. Isolator Current Rating Poles Ordering 40 Double Pole GLISDP40. 63 Double Pole GLISDP63. 40 Triple Pole GLISTP40.

6 63 Triple Pole GLISTP63. 40 Four Pole GLISFP40. 63 Four Pole GLISFP63. For marked MCBs please contact your nearest GE sales office A9. Safetrip Residual Current Circuit Breakers Keeping you safe Salient Features Technical Details Conforms to IEC61008-1 Rated Current(In) : 25A, 40A, 63A. 2 Pole & 4 Pole Sensitivity* : 30mA, 100mA, 300mA. Trip free mechanism Number of Poles : 2 Pole and 4 Pole Disconnection with positive contact Rated Voltage : 240/415V AC. Antiwelding contacts Insulation Voltage : 500V AC. Bi-connect facility Frequency : 50/60Hz Touch proof terminals IP20 Operating Temp. Range : -250C to +600C. Resistance against unwanted tripping Terminal Capacity : 25mm2. Test facility - A test button T' provided on device Mounting Arrangement : 35mm DIN Channel No ageing effect Service Life : 20000 operations Compatibility with all DBs Optional Accessories : Aux.

7 Contact, shunt & undervoltage release, motor operator & panel board switch Protection *500mA sensitivity available on request for Industrial applications Personal protection - Against electrocution The use of exposed, substandard and poorly wired, or damaged equipment reduces the safety of an installation and increases the risk of an electric shock to the person in contact. Electrocution is a passage of current flowing through human body which affects the vital functioning like breathing and heartbeat. This can be very dangerous to the person in contact depending upon current and time for which it flows. A correctly selected RCCB can detect even small currents flowing to earth and reduces the risk of electrocution. The effect of electric current through human body has been well researched and is as below. 500mA Immediate cardiac arrest resulting in death 70-100mA Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate This situation is dangerous since it is irreversible 20-30mA Muscle contraction can cause respiratory paralysis 10mA Muscle contraction: the person remains stuck to the conductor 1-10mA Prickling sensations B11.

8 However, electrocution should not be viewed in terms of current alone but in terms of contact voltage . A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body. The human body has known limits: In a dry environment, voltage limit = 50V. In a humid environment, voltage limit = 25V. Against Indirect Contact Zone Physiological effects Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring 1 Usually has no reactions or effects. regulations the earth fault loop impedance in Ohms, multiplied 2 Usually has no harmful effects. by the rated tripping current of the RCD in amperes must not exceed 50. 3 Usually, no organic damage is expected.

9 Here the likelihood present is of muscular contractions and difficulty in breathing. Reversible disturbances in the formation and conductance of impulses in the Against Fire heart, including arterial fibrillation and transient The majority of fires in an electrical installation are result of cardiac arrest without ventricular fibrillation are leakage current flowing to earth and even a current of the order possible. These effects increase with current of 1A can lead to big fire. These type of faults are not detected by magnitude and time. the normal short circuit protection device like MCB or Fuse. A. 4 In addition to the effects of Zone 3, the probability of correctly selected RCCB will detect this leakage and save the risk ventricular fibrillation increases from 5% (curve c2), of fire saving the installation. to about 50% (curve c3) and beyond 50% above (curve c3).

10 Increasing with magnitude and time are pathophysiological effects as cardiac and breathing arrest, whilst heavy burns are possible. B12. Selection 30mA - This RCCB will provide a high degree of protection against 100mA - This RCCB will normally give high degree of protection electrocution. The current flowing through human body depends against electrocution but there is a possibility that the shock upon the resistance of human body and voltage across it and can current could fall below the tripping level of RCCB. This could occur vary between 80mA to 240mA. To be within zone of the IEC curve if additional resistances to that of human body are included in the as shown in chart. It is necessary for the RCCB to operate within earth path. The 100mA RCCB protects against leakage currents 50ms at 240mA and 150ms at 80mA. Both these conditions are and indirect contact with earth loop impedance upto 500 Ohms.