Example: tourism industry

SOYAL AR-725H/AR-757H AR-321H/AR-721H/

AR- 321h /AR- 721h /. SOYAL .. ACCESS CONTROL SYSTEM. AR- 725h /AR- 757h V100628. Contents AR- 321h [Touch-panel Metal Housing]. 1 Product 2 User Guide 3 Terminal Cables 4 Tools 5 Water proof Strip d x2. P1 P2 P3 P4. AR- 721h . 1 Product 2 User Guide 3 Terminal Cables 4 Tools f x2. P1 P2 P3 P4. AR- 725h [Illuminated Touch-panel]. AR- 725h -M. 1 Products 2 User Guide 3 Terminal Cables 4 Tools c x2. P1 P2. e x1. P3 P4. A. B. C. D. AR- 725h . 1 Products 2 User Guide 3 Terminal Cables 4 Tools P1 P2 f x2. A1. E. F. P3 P4. AR-725X. 1 Products 2 Tools a x2 e x1. b x2. c x2. A2. A3. B. C. G. H. D. AR- 757h . 1 Product 2 User Guide 3 Terminal Cables 4 Tools f x2. P1 P2 P3 P4 P6. Parts Description a. b. c. d. Button Head Pozidriv Button Head Pozidriv Flat Head Cap Philips Flat Head Cap Philips Tapping Screw: M3x10 Slotting Screw: Tapping Screw: Tapping Screw: 4x38.

SOYAL ACCESS CONTROL SYSTEM ® AR-321H/AR-721H/ AR-725H/AR-757H V100628 Enter the program mode Input 123456 or PPPPPP [e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed

Tags:

  321h, Ar 725h ar 757h ar 321h ar 721h, 725h, 757h, 721h, Ar 321h ar 721h, Ar 725h ar 757h

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SOYAL AR-725H/AR-757H AR-321H/AR-721H/

1 AR- 321h /AR- 721h /. SOYAL .. ACCESS CONTROL SYSTEM. AR- 725h /AR- 757h V100628. Contents AR- 321h [Touch-panel Metal Housing]. 1 Product 2 User Guide 3 Terminal Cables 4 Tools 5 Water proof Strip d x2. P1 P2 P3 P4. AR- 721h . 1 Product 2 User Guide 3 Terminal Cables 4 Tools f x2. P1 P2 P3 P4. AR- 725h [Illuminated Touch-panel]. AR- 725h -M. 1 Products 2 User Guide 3 Terminal Cables 4 Tools c x2. P1 P2. e x1. P3 P4. A. B. C. D. AR- 725h . 1 Products 2 User Guide 3 Terminal Cables 4 Tools P1 P2 f x2. A1. E. F. P3 P4. AR-725X. 1 Products 2 Tools a x2 e x1. b x2. c x2. A2. A3. B. C. G. H. D. AR- 757h . 1 Product 2 User Guide 3 Terminal Cables 4 Tools f x2. P1 P2 P3 P4 P6. Parts Description a. b. c. d. Button Head Pozidriv Button Head Pozidriv Flat Head Cap Philips Flat Head Cap Philips Tapping Screw: M3x10 Slotting Screw: Tapping Screw: Tapping Screw: 4x38.

2 E. f. Security Torx Screw: Flat Head Hex Socket Screw: M3x8. Access Controller Touch-panel Metal Housing / Illuminated Touch-panel V100628. Installation AR- 321h [Touch-panel Metal Housing]. 3. Pull the cables from the square hole of the mounting plate. Use a screwdriver to screw the mounting plate onto the wall. Attach the water proof strip to the body, then connect the terminal cables to the body and attach the body to the mounting plate. 2 Use the Allen key and screws (accessories supplied) to assemble the body onto the mounting plate. 1. 4. Turn on the power, and LED will light and beep will sound. AR- 721h . Pull the cables from the square hole of the mounting plate. Use a screwdriver to screw the base onto the wall.

3 Connect the terminal cables to the body and attach the body to the mounting plate. 4 Assemble the covers with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. AR- 725h [Illuminated Touch-panel]. AR- 725h -M. Pull the cables from the square access hole of the mounting plate C. Use a screwdriver to screw the metal plate C onto the wall. A. A. 7. 3. A. B. C. Take off the plastic mounting plate B from the body A, and pull the cables 2. C. A. C. B. through the access hole of C and B, then connect to the body A. 6. Assemble plate B with the body A, and embed the water proof strip D. 4. 1 B. 5 onto the plastic side frame. d. c. 8 Assemble the body A onto the mounting plate C with the Allen key and D.

4 Screws (accessories supplied). Turn on the power and LED will light and beep will sound. AR- 725h . F. E. Use a screwdriver to screw the base F onto the wall. 1 F. A1. 2 Attach the water proof gasket to the body A1, and pull the cables 3. from the square hole of the base F, and connect to the body A1. Assemble the body A1 with the base F. 4. Screw A1 and F tight with the Allen key and screws (accessories e. supplied). 5. Turn on the power and LED will light and beep will sound. AR-725X. Put on G, and attach A1 onto the plastic plate A3, and screw it with A1. A1.+A3. D. 2. H. the Allen key and screws (accessories supplied). A3. 1 A2. Put the ring O on the metal frame, and put them together onto the b.

5 4 reader A1+A3, and screw them and buckle up the 4 buckles on the a. back. e. G. 3 5 Embed the water proof strip D onto the frame side of the base. Following by the install process of AR- 725h -M. AR- 757h . Pull the cables from the square hole of the mounting plate. Use a screwdriver to screw the base onto the wall. Connect the terminal cables to the body and attach the body to the mounting plate. 4 Assemble the covers with the Allen key and screws (accessories supplied). Turn on the power and LED will light and beep will sound. Notice : The communication wires and power line should NOT be bound in the same conduit or tubing. selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring. supply: Don't equip controller and lock with the same power supply.

6 The power for controller may be unstable when the lock is activating, that may make the controller malfunction. The standard installation: Door relay and lock use the same power supply, and controller use independent power supply. AR- 321h /AR- 721h /. SOYAL .. ACCESS CONTROL SYSTEM. AR- 725h /AR- 757h V100628. Connector Table AR- 321h [Touch-panel Metal Housing]. 125kHz Cable: P1. P4 P5 Wire Application Pin Color Description Door Relay 1 Blue White ( ) DC24V1 Amp P3 P2. 2 Purple White ( ) DC24V1 Amp P1 Common-COM-Point 3 White (COM) DC24V1 Amp Door Sensor 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input AR- 721h Alarm Relay 6 Gray or shift by JP1 jumper and Shared Com with Door Relay 125kHz Power 7 Thick Red DC Power 12V.

7 P3 8 Thick Black DC Power 0V. P2. P1 P1. P2 Cable: P2. Wire Application Pin Color Description P4. P5. P4 P3 Wiegand 1 Thin Blue Wiegand DAT:1 Input P5 2 Thin Green Wiegand DAT:0 Input Beeper 3 Pink Beeper Output 5V/100mA, Low AR- 725h [Illuminated Touch-panel]. LED 4 Brown LED Green Output 5V/20mA, Max 125kHz 5 Yellow LED Red Output 5V/20mA, Max P2 P3 P5 P2. Cable: P3. P1 P1. P5. Wire Application Pin Color Description P4 P3 Networking 1 Thick Green RS-485(B-). P4. Module 2 Thick Blue RS-485(A+). AR- 757h . Cable: P4 Contact Rating: 1A 125 VAC/24 VDC. 125kHz Main Board Main Board Wire Application Pin Color Description Tamper Switch 1 Red P2 P2. P6 P6 2 Orange COM. 3 Yellow P4 P4 After S/N: 0706-XXXXXX.

8 I/O Board I/O Board Cable: P5 (Optional). Wire Application Pin Color Description P3 P1 P3 P1 3-PIN Connector 1 Black GND. Connectors Comparison 2 White Duress 3 Purple Arming/ Security trigger signal AR- 321h 125kHz P1 P2 P3 P4 ( P5 Optional). 125kHz P1 P2 P3 P4 ( P5 Optional). AR- 721h Cable: P6. P1 P2 P3 P4 ( P5 Optional) Wire Application Pin Color Description 125kHz P1 P2 P3 P4 ( P5 Optional) Door bell 1 Brown White BE Output AR- 725h . P1 P2 P3 P4 ( P5 Optional) Arming 2 Red White AR Output/ Security trigger signa Output Duress 3 Yellow White DU Output/ TTL out 125kHz P1 P2 P3 P4 P6 LED indicator 4 Green White Hi input/ Green light brighten AR- 757h . P1 P2 P3 P4 P6. Wiring Diagram AR- 321h to Magnet Lock or Electric Bolt Connect Connect to Electric Strike 12V 12V 12V 12V.

9 POWER POWER. GND GND GND GND. or 12 VDC 12 VDC. Electric Bolt Magnet Lock Electric Strike P1 P1. 1 1. 2 2. COM 3 COM 3. 4 4. PB 5 PB 5. 6 6. 12V 7 12V 7. GND 8 GND 8. Controller EXIT Controller EXIT. 12V 12V. POWER POWER. GND Push Button GND Push Button 12 VDC 12 VDC. Access Controller Touch-panel Metal Housing / Illuminated Touch-panel V100628. Connect AR- 321h to Reader Connect to Door Sensor 12V 12V. POWER. GND GND. Reader Controller 12 VDC. P1 Alarm WG 1 1 WG 1 1. WG 0 2 WG 0 2 P1. BZ 3 BZ 3 1. GLED GLED 4 4 2. RLED RLED 5 5 3. COM. 12V P2 6 Door Sensor 4. 12V CTL. GND 7 5. GND 12V. 8 ALM 6. 12V 7 Relay Outpot Module GND 8. GND. POWER Controller 12V 12 VDC. 12V. POWER GND. 12 VDC Door Sensor Connect AR- 321h to strengthen security with AR-721RB Connect to Networking 12V 12V GND.

10 GND. POWER Converter POWER. GND A+ 12V. 12 VDC B- 12 VDC. Electric Bolt Node 1 Node 8. COM. CTL. Node ID 001. B- 1 B- 1. 12V AR-716E P3 A+ P3 A+. P5 1 GND 2 2. 2 PB. 1 2 3 Host B- Controller Controller 3 AR-721RB A+. ARM 4. P1 B- 5 CH1. A+. 6 B- 12V 7 CH2. A+. GND 8. Controller Controller Controller EXIT. 12V Controller POWER GND B- 1 B- 1. P3 P3. 12 VDC Push Button P3. B- 1 A+ 2 A+ 2. A+ 2. the security trigger signal: 34 128 Node ID 254 Node 9 Node 16. the door open button input. (Please refer to the 20 DDD of function default value.). Adding and Deleting Tag Mode4/Mode8. Add Single Tag or Random tags Input 123456 (or Master Code) 19 UUUUU 00001 Present the tag(s) with Controller (single tag or random numbered cards one by one) Done [ ] 2 readom cards with user addresses No.