Example: biology

SPECIFICATION FEATURES HOUSING …

Sure-LitesSPECIFICATION FEATURESDIMENSIONSDESCRIPTIONThe Sure-Lites SELIN industrial series is a UL 924 code compliant emergency light designed to reduce total egress system cost and maintenance as well as ensure reliability in an industrial or wet location environment. It is designed to run for a minimum of 90 minutes during a power outage. Key FEATURES include a long life LED source with egress coverage up to 60 feet, a nickel cadmium battery and self-diagnostics which automates the NFPA required testing. The fixture is NEMA 4X, IP66, Title 20 compliant and has a chemically resistant fiberglass HOUSING . This series offers remote capability from 4 watts to 10 watts and is compatible with the Sure-Lites SRP/SRM remote Dual Voltage Input 120/277 VAC, 60Hz- Brownout circuit- Low voltage disconnect- Overload / Short Circuit protection- Battery back-up- Self-diagnostic - Remote capability HOUSING CONSTRUCTION- UL listed NEMA 4X fiberglass- Watertight and corrosion resistant- Gasketed; internally hinged front cover- Grey finish- All units come standard with a breather ventBATTERY- Sealed Nickel Cadmium- Full Recharge Time, 24 hours (max.)

Sure-Lites SPECIFICATION FEATURES DIMENSIONS DESCRIPTION The Sure-Lites SELIN industrial series is a UL 924 code compliant emergency light designed to reduce total egress system cost and

Tags:

  Feature, Specification, Specification features

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SPECIFICATION FEATURES HOUSING …

1 Sure-LitesSPECIFICATION FEATURESDIMENSIONSDESCRIPTIONThe Sure-Lites SELIN industrial series is a UL 924 code compliant emergency light designed to reduce total egress system cost and maintenance as well as ensure reliability in an industrial or wet location environment. It is designed to run for a minimum of 90 minutes during a power outage. Key FEATURES include a long life LED source with egress coverage up to 60 feet, a nickel cadmium battery and self-diagnostics which automates the NFPA required testing. The fixture is NEMA 4X, IP66, Title 20 compliant and has a chemically resistant fiberglass HOUSING . This series offers remote capability from 4 watts to 10 watts and is compatible with the Sure-Lites SRP/SRM remote Dual Voltage Input 120/277 VAC, 60Hz- Brownout circuit- Low voltage disconnect- Overload / Short Circuit protection- Battery back-up- Self-diagnostic - Remote capability HOUSING CONSTRUCTION- UL listed NEMA 4X fiberglass- Watertight and corrosion resistant- Gasketed; internally hinged front cover- Grey finish- All units come standard with a breather ventBATTERY- Sealed Nickel Cadmium- Full Recharge Time, 24 hours (max.)

2 - 0 to 40 C (32 to 104 F)WARRANTY- Five-year product warranty- Prorated seven-year battery warrantyCODE COMPLIANCE- UL924 wet location listed for 0 C to 40 C operation- Life Safety NFPA 101- NEMA 4X / IP66- NEC/OSHA/NSF- Most State & Local Codes- California Energy Code CompliantSELIN Emergency LightLED Emergency LightSelf-DiagnosticsSELINR emote CapacityWet LocationNEMA 4 XIP 669-11/16"246mm8-1/2"216mm5/8"16mm6-1/2" 165mm11-15/16"303mm4-1/8" ANGLE PROJECTIONMATERIAL:SHEET METAL PIERCED,EXTRUDED, NAIL PUNCH HOLEMETRIC (MM)ENGLISH (IN). ARE IN INCHESDIMENSIONS IN [ ] ARE IN MMELECTRONIC CAD DRAWING. DO NOT REVISE 141312111098765432 PAGEREVUSE WITH MULTI-SHEET DRAWINGSTITLE:SIZE:DWG NO:REV:SHEETVOL:WT:SCALE:SURFACE AREA:DO NOT SCALE DRAWINGFINISH:APPR:CHKD: CRITICALDIMENSIONS ANDGUAGE CHECK POINTSDENOTES FIRST PIECE AND IN-PROCESS INSPECTIONDENOTES FIRST PIECE INSPECTION ONLYFPCCONFIDENTIAL - The information contained in this document is the property of Cooper Industries, Inc.

3 It is not for public disclosure. Possession of the information does not convey any right to loan, sell, or disclose the information. Unauthorized reproduction or use of the information is prohibited. This document is to be returned to Cooper Industries Inc. upon completion of the purpose for which it was loaned or upon request. COPYRIGHT Cooper Industries Inc. This is an unpublished work. The disclosure of this work is limited to select personnel. Further dissemination or disclosure to the public is PROHIBITED. This unpublished work is protected by Federal Copyright law and all rights thereunder are reserved by Cooper Industries, LB1 SELIN_LineArt_2018_03L MOD:E04389103/27/2018 DIMENSIONS THAT AFFECT SAFE HANDLING OR IN3 DEV/ZINT NO:MUST CONFORM TO ROHS SPECIFICATION CL-ES-10251OF + + (MM)ENGLISH (IN)SELIN25 / SELIN50 / SELIN60operatingtemperaturerange-20 to 50 Coperatingtemperaturerange 0 to 40 CLighting Options for Your Home.

4 As the market transitions, here are options to consider as you look to increase energy 2012TD505068 ENJune 4, 2018 11:48 AMCatalog # Type Date Project Comments Prepared by Sure-LitesSELIN EMERGENCY LIGHTCATALOG LOGICSAMPLE NUMBER: SELIN25R10SD, SELIN50R75D, SELIN60R4 SDSeriesSpacingBatteryRemote CapacitySelf-DiagnosticFull CatalogSELIN = LED Emergency Light25 = 25 feet__= NiCadR10 = 10 wattsSD = Self-Diagnostic(standard)SELIN25R10SD50 = 50 feet__= NiCadR7 = 7 watts SD = Self-Diagnostic(standard)SELIN50R7SD60 = 60 feet__= NiCadR4 = 4 watts SD = Self-Diagnostic(standard)SELIN60R4 SDELECTRICAL CHARACTERISTICS DURING CHARGING MODEM odelPower (W)Current (A)PFPower (W)Current (A) / SELIN50 / SELIN60 Sure-LitesSELIN EMERGENCY LIGHTREMOTE SYSTEM DESIGN GUIDELINESSELIN25 / SELIN50 / SELIN60 SRPSRPDSRMSRMDSRPA WHITESRPA BLACKSRPA BRONZESRPA SILVERSEL Series Outdoor Capable RemotesValuePropositionSeriesSRPAS ingle Head RemotesDouble Head RemotesCatalog numberSRPA29 SRP/SRM13 SRP/SRM25 SRP/SRM30 SRP25D/SRM25 DSRP50D/SRM50 DSRP60D/SRM60 DWatts NumberRemote Watts Available# of SRPA29 remotes fixture will power# of SRP/SRM13 remotes fixture will power# of SRP/SRM25remotes fixture will power# of SRP/SRM30 remotes fixture will power# of SRP25D/SRM25D remotes fixture will power# of SRP50D/SRM50D remotes fixture will power# of SRP60D/SRM60D remotes fixture will powerTotal Potential Egress CoverageSELIN25R10SD102842421125 feetSELIN50R7SD7252121NA115 feetSELIN60R4SD4131NA1 NANA99

5 FeetSure-LitesSELIN EMERGENCY LIGHTPHOTOMETRY**The Rule of Thumb spacing guidelines are designed to achieve 1 foot-candle average and foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is feet. Eaton assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code 51584050 5125271 7. 5552725 EMERGENCY LIGHTPHOTOMETRY**The Rule of Thumb spacing guidelines are designed to achieve 1 foot-candle average and foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress.

6 The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is feet. Eaton assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code : : : : 51705760 DATASelf-DiagnosticsThe self-diagnostic sotfware will automatically perform all tests required by UL924, and NFPA101 and will systematically calibrate itself in the field; thus reducing installation labor and eliminating manual calibration errors. The system indicates the status of the emergency light at all times using the LED indicator. A 90 minute battery power (emergency mode) simulation test will occur once every 12 months. A 30 second battery power simulation test will occur every 30 days. The Solid-State microprocessor based system has the ability to accurately detect and warn of system failures, plus it incorporates all of the standard electronic FEATURES that sets Sure-Lites apart from its CapablityThe SELIN series offers remote capability from 4 watts to 10 watts.

7 This enables the ability to power the Sure-Lites SRP/SRM/SRPA series remotes to create an emergency system capable of covering up to 125 feet. The Sure-Lites SRP/SRM/SRPA remotes are UL listed for wet locations and are rated for temperatures from - 30 C to 60 Voltage DisconnectThe low-voltage circuitry disconnects the lighting load to protect the battery after run times in excess of the 90-minute UL limit. The disconnect remains in effect until normal utility power is restored preventing deep battery discharge. Brownout CircuitThe brownout circuit on the SELIN emergency light monitors the flow of AC current to the unit and activates the emergency light heads when a predetermined reduction of AC power TestThe Self-Diagnostic option include a laser pointer testing cability. Activation of the photocell test button with a laser pointer will simulate loss of AC power and engage the emergency operation of the exit and emergency heads.

8 WarrantySELIN units are backed by a five-year warranty on the fixtures and a seven-year prorated battery testerPart Number = LASER(sold separately)Eaton1121 Highway 74 SouthPeachtree City, GA 30269P: and dimensions subject to change without EMERGENCY LIGHTOFF - EMERGENCY MODE / POWER OFF2 BLINK RED - BATTERY FAILURESTEADY GREEN - FULL / FLOAT CHARGESTEADY BLINK YELLOW - 90 MINUTE TEST3 BLINK RED - CHARGE CIRCUIT FAILURE4 BLINK RED - LAMP/ LED FAILURESTEADY YELLOW - QUICK TESTSTEADY BLINK GREEN - FAST CHARGESURE-LITES SELF-DIAGNOSTIC TESTING OPERATIONSThe Sure-Lites self-diagnostics is continuously monitoring your emergency fixture, and will signal any failure through the 3 color indicator Operation:When the unit is first powered up it will go into a 24 hour fast charge and the indicator LED will pulse green.

9 Once the unit has fully charged it will perform a self calibration. After self calibration, the LED will change to steady green indicating the unit is fully charged and float charging the battery to maintain Testing:The unit will perform a battery capacity, lamp/LED, and charge circuit test every 30 days for 30 seconds. During this time, the indicator LED will change to a steady yellow. It will perform a full battery capacity (90 minute) test once per year. During this time, the indicator LED will change to a blinking Testing: 10 Second Installation test Press and release the test button once during fast charge (blinking green) to initiate a 10 second quick test. The sign will switch to emergency mode for 10 seconds allowing the installer to verify proper installation of the unit, and the LED indicator will turn solid yellow.

10 30 Second Test - Press and release the test button once during float charge (steady green). The indicator LED will turn steady yellow to indicate the unit is performing a 30 second test of the batteries and lamps/LEDs. 90 Minute Test - Press and release the test button a second time during a 30 second test (steady yellow) to change to a 90 minute test. During this test, the LED indicator will change to blinking yellow, and the circuit will perform a full battery capacity, charge circuit, and LED test. Canceling Test Press and release the test button during the 90 minute test (flashing yellow) to return the fixture to its original state (fast charge or float charge)Laser Test:The SEL SD products are equipped with a Laser Test function that allows the unit to be manually tested without the need to physically press the test button.


Related search queries