Specification sheet Diesel generator set 25 kW - 40 kW. EPA emissions stationary standby Description Cummins Power Generation generator sets are Cooling system - Standard cooling package fully integrated power generation systems provide reliable running at up to 50 C (122 F). providing optimum performance, reliability and ambient temperature. versatility for stationary standby applications. Enclosures - The aesthetically appealing Features enclosure incorporates special designs that Cummins heavy-duty engine - Rugged 4- deliver one of the quietest generators of its kind. cycle, liquid-cooled, industrial Diesel engine Aluminum material plus durable powder coat delivers reliable power, low emissions and fast paint provides the best anti-corrosion response to load changes.

Diesel generator set . 25 kW - 40 kW . EPA emissions stationary standby . Description . Cummins Power Generation generator sets are fully integrated power generation systems

Tags:

  Sheet, Specification, Generators, Diesel, Specification sheet diesel generator set

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Specification sheet Diesel generator set

1 Specification sheet Diesel generator set 25 kW - 40 kW. EPA emissions stationary standby Description Cummins Power Generation generator sets are Cooling system - Standard cooling package fully integrated power generation systems provide reliable running at up to 50 C (122 F). providing optimum performance, reliability and ambient temperature. versatility for stationary standby applications. Enclosures - The aesthetically appealing Features enclosure incorporates special designs that Cummins heavy-duty engine - Rugged 4- deliver one of the quietest generators of its kind. cycle, liquid-cooled, industrial Diesel engine Aluminum material plus durable powder coat delivers reliable power, low emissions and fast paint provides the best anti-corrosion response to load changes.

2 Performance. The generator set enclosure has been evaluated to withstand 180 MPH wind loads Alternator - Several alternator sizes offer in accordance with ASCE7-10. The intelligent selectable motor starting capability with low design has removable panels and service doors reactance 2/3 pitch windings, low waveform to provide easy access for service and distortion with non-linear loads and fault clearing maintenance. short-circuit capability. Fuel tanks - Two dual wall sub-base fuel tank Control system - The PowerCommand series are offered as optional features, providing electronic control is standard equipment and economical and flexible solutions to meet provides total generator set system integration extensive code requirements on Diesel fuel tanks.

3 Including automatic remote starting/stopping, precise frequency and voltage regulation, alarm NFPA - The generator set accepts full rated load and status message display, output metering, in a single step in accordance with NFPA 110 for auto-shutdown at fault detection and NFPA 110 Level 1 systems. Level 1 compliance. Warranty and service - Backed by a comprehensive warranty and worldwide distributor and dealer network. Standby rating Prime Rating Data sheets 60 Hz 60 Hz 60 Hz Model kW kVA kW kVA. C25 D6 25 NAD-5859. C30 D6 30 27 NAD-5860. C35 D6 35 32 40 NAD-5861. C40 D6 40 50 36 45 NAD-5862. 2014 Cummins Power Generation Inc. | NAS-5872a-EN (6/14). generator set specifications Governor regulation class ISO 8528 Part 1 Class G2.

4 Voltage regulation, no load to full load Random voltage variation - 3 Phase only Frequency regulation Isochronous Random frequency variation Radio frequency emissions compliance FCC code Title 47 part 15 Class B. Engine specifications Bore mm ( in). Stroke mm ( in). Displacement litres (199 in3). Configuration Cast iron, in-line, 4 cylinder Battery capacity 550 amps at ambient temperature of 0 F to 32 F (-18 C to 0 C). Battery charging alternator 40 amps Starting voltage 12 volt, negative ground Indirect injection, number 2 Diesel fuel, fuel filter, electric fuel shut Fuel system off Single element, 10 micron filtration, spin-on fuel filter with water Fuel filter separator Air cleaner type Dry replaceable element Lube oil filter type(s) Spin-on, full flow Standard cooling system 50 C (122 F) ambient cooling system Alternator specifications Design Brushless, 4 pole, drip proof, revolving field Stator 2/3 pitch Rotor Direct coupled, flexible disc Insulation system Class H per NEMA Standard temperature rise 120 C (248 F) standby Exciter type Torque match (shunt)

5 With PMG/EBS as option Alternator cooling Direct drive centrifugal blower AC waveform total harmonic distortion < 5% no load to full linear load, < 3% for any single harmonic Telephone influence factor (TIF) < 50 per NEMA Telephone harmonic factor (THF) Available voltages Single phase 3 phase 120/240 120/208 120/240 delta 277/480 347/600. Note: Consult factory for other voltages. generator set options Fuel system Control Cooling system Warranty Basic fuel tanks AC output analog meters (bargraph) Shutdown low coolant level Base warranty 2 year, 400. Regional fuel tanks Stop switch emergency Warning low coolant level hour, standby Engine Auxiliary output relays (2) Extension coolant drain Standby, 3 year, 900 hour, parts Engine air cleaner normal or Auxiliary configurable signal Coolant heater 120 V, 1 Ph Standby, 5 year, 1500 hour, heavy duty inputs (8) and relay outputs (8)

6 Exhaust system parts Shut down low oil pressure Electrical Exhaust connector NPT Standby, 3 year, 900 hour, parts Extension oil drain Single circuit breaker and labor generator set application Standby, 5 year, 1500 hour, 120 V 1000 W coolant heater Dual circuit breakers Battery rack parts and labor Alternator Enclosure Battery rack, heavy duty Standby, 3 year, 900 hour, One size up alternator Aluminum enclosure Sound parts, labor and travel Excitation boost system (EBS) or Level 1 or Level 2, with muffler Standby, 5 year, 1500 hour, PMG installed, sandstone or green color parts, labor and travel Alternator heater, 120 V Open set Note: Some options may not be available on all models - consult factory for availability.

7 generator set accessories Coolant heater Battery charger stand-alone, 12 V. Extreme cold weather components Circuit breakers HMI211RS in-home display, including pre-configured 12 harness Enclosure Sound Level 1 to Sound Level 2 upgrade kit HMI211 remote display, including pre-configured 12 harness Enclosure paint touch up kit HMI220 remote display Mufflers industrial, residential or critical Auxiliary output relays (2) Alternator excitation boost system (EBS) or PMG. Auxiliary configurable signal inputs (8) and relay outputs (8) Alternator heater Annunciator RS485 Maintenance and service kit Remote monitoring device PowerCommand 500 Engine lift kit Various fuel tanks and accessories 2014 Cummins Power Generation Inc.

8 | NAS-5872a-EN (6/14). Control system PowerCommand Alternator data Line-to-line and Line-to-neutral AC volts 3-phase AC current Frequency Total kVa Engine data DC voltage Lube oil pressure PowerCommand control is an integrated generator Coolant temperature set control system providing voltage regulation, engine Engine speed protection, operator interface and isochronous Other data governing (optional). Major features include: Battery monitoring and testing features and smart generator set model data starting control system. Start attempts, starts, running hours Standard PCCNet interface to devices such as Fault history . remote annunciator for NFPA 110 applications. RS485 Modbus interface Control boards potted for environmental protection.

9 Data logging and fault simulation (requires InPower Control suitable for operation in ambient service tool). temperatures from -40 C to +70 C (-40 F to Digital governing (optional). +158 F) and altitudes to 5000 meters (13,000 feet). Integrated digital electronic isochronous governor Prototype tested; UL, CSA, and CE compliant. Temperature dynamic governing . InPower PC-based service tool available for detailed diagnostics. Digital voltage regulation Operator/display panel Integrated digital electronic voltage regulator 2-phase line-to-line sensing Manual off switch Configurable torque matching Alpha-numeric display with pushbutton access for viewing engine and alternator data and providing Control functions setup, controls and adjustments (English or Time delay start and cooldown international symbols) Cycle cranking LED lamps indicating generator set running, not in PCCNet interface auto, common warning, common shutdown, manual (2) Configurable inputs run mode and remote start (2)

10 Configurable outputs Suitable for operation in ambient temperatures from Remote emergency stop -40 C to +70 C Automatic transfer switch (ATS) control Bargraph display (optional) generator set exercise, field adjustable AC protection Options Over current warning and shutdown Auxiliary output relays (2). Over and under voltage shutdown Remote annunciator with (3) configurable inputs and Over and under frequency shutdown (4) configurable outputs Over excitation (loss of sensing) fault PMG alternator excitation Field overload PowerCommand 500/550 for remote monitoring and Engine protection alarm notification (accessory). Auxiliary, configurable signal inputs (8) and Overspeed shutdown configurable relay outputs (8).