Example: air traffic controller

SPECIFICATIONS FOR THE APPROVAL, SUPPLY, …

January 2019 - 1 - specification No. 1280 Transportation SPECIFICATIONS FOR THE approval , supply , AND APPLICATION OF DUST CONTROL specification No. 1280 January 2019 January 2019 - 2 - specification No. 1280 SPECIFICATIONS FOR THE approval , supply , AND APPLICATION OF DUST CONTROL Scope This specification governs the approval , supply and application of chemicals used for dust control and stabilization on gravel roads.. References ASTM D 98 Standard specification for Calcium Chloride ASTM D 1293 Standard Test Methods for pH of Water ASTM D 1429 Standard Test Methods for Specific Gravity of Water and Brine ASTM E 449 Standard Test Methods for Analysis of Calcium Chloride Pulp and Paper Association of Canada Standard H1 Determination of Solids Content of Pulp and Paper Mill Effluents Standard Methods for the Examination of Water and Wastewater, 3120 Metals by Plasma Emmision Spectrosco

March 2011 - 1 - Specification No. 1280 . SPECIFICATIONS FOR . THE APPROVAL, SUPPLY, AND APPLICATION OF DUST CONTROL. Specification No. 1280 . March 2011

Tags:

  Specification, Supply, 2018, Approval, Specifications for the approval, Specifications for, The approval

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SPECIFICATIONS FOR THE APPROVAL, SUPPLY, …

1 January 2019 - 1 - specification No. 1280 Transportation SPECIFICATIONS FOR THE approval , supply , AND APPLICATION OF DUST CONTROL specification No. 1280 January 2019 January 2019 - 2 - specification No. 1280 SPECIFICATIONS FOR THE approval , supply , AND APPLICATION OF DUST CONTROL Scope This specification governs the approval , supply and application of chemicals used for dust control and stabilization on gravel roads.. References ASTM D 98 Standard specification for Calcium Chloride ASTM D 1293 Standard Test Methods for pH of Water ASTM D 1429 Standard Test Methods for Specific Gravity of Water and Brine ASTM E 449 Standard Test Methods for Analysis of Calcium Chloride Pulp and Paper Association of Canada Standard H1 Determination of Solids Content of Pulp and Paper Mill Effluents Standard Methods for the Examination of Water and Wastewater, 3120 Metals by Plasma Emmision Spectroscopy Materials Manitoba Infrastructure (MI) will specify delivery and application of one or more of the following products.

2 1. 38% Liquid Calcium/Magnesium Chloride 2. 35% Liquid Calcium/Magnesium Chloride 3. 34% Liquid Calcium/Magnesium Chloride 4. 30% Liquid Calcium/Magnesium Chloride 5. 77% Flake Calcium/Magnesium Chloride 6. Liquid Magnesium Chloride 7. Liquid Magnesium Chloride 8. 28% Liquid Magnesium Chloride 9. Lignosulfonate - Solution (Liquid) 10. Lignosulfonate - Solution & Carbohydrates (Liquid) . specification for supply of Material The chemicals shall comply with the requirements of Table 1.. Chemical Requirements Liquid Calcium/Magnesium Chloride (Ca/MgCl2) shall be composed of CaCl2 or a January 2019 - 3 - specification No.

3 1280 combination of CaCl2 and MgCl2. The quantity for chloride chemicals shall be calculated to achieve strength equivalency with a 77% pure flake calcium chloride (CaCl2).. Water Water used in the solution shall be free of contaminants that could adversely affect either field material performance or the environment. Table 1: Chemical specification CHEMICAL Requirements Calcium/ Magnesium Chloride Liquid Calcium/ Magnesium Chloride Flake Magnesium Chloride Liquid Lignosulfonate (Liquid) Test Method(1) Solution Minimum Concentration Percentage (by mass)(2) 38% 35% 34% 30% 77% 28% ICP-AES as described in Standard Methods for the examination Water and Waste Water , Sec.

4 3120, APHA-AWWA-WEF Gradation (Percent Passing) mm mm 600 m 100 80-100 0-5 ASTM D98 Minimum Percentage of Total Solids (by mass) 27% Canada Pulp and Paper Association Standard Method Product Specific Gravity ASTM D-1429 pH 3-8 ASTM D-1293 Equivalency % 88 98 100 118 88 100 108 NOTES: 1. All Test Methods refer to the current version. 2. Alkali Chloride determination, as required for Minimum Concentration analysis, is calculated by use of ASTM E449. January 2019 - 4 - specification No. 1280 Pre- approval of Suppliers Products that have been approved and are on the Department s Product Standards List, do not need to go through the procedures in sections , and.

5 Sampling If a product has not been approved by the Department, a three-litre sample of the applicable liquid chemical or 30 Kg of flakes shall be supplied clearly labelled and sent to: Manager, Materials Engineering Central Lab Manitoba Infrastructure 1181 Portage Avenue (Annex) Winnipeg, Manitoba R3G 0T3 If the chemical in the requisition is classified as a Controlled Product, as defined in the Hazardous Products Act, Canada, and the Supplier has not previously submitted a Material Safety Data Sheet to THE DEPARTMENT, then the Supplier at the time of submitting the tender shall submit a valid Material Safety Data Sheet and any required updates to both the above address and to the following address.

6 Manager, Occupational Safety, Health & Risk Management Manitoba Infrastructure 17th Floor, 215 Garry Street Winnipeg, Manitoba R3C 3Z1 Suppliers shall, in the submission for approval , include the following information: 1. Technical data and chemical composition (ion concentration mg/L) of the product to be supplied, 2. Names, addresses and telephone numbers of sales agents, dispatchers and technical support staff.. Sample Testing All samples submitted shall be tested by the Department or a lab accredited by Standards Council of Canada (SCC) or Canadian Association for Environmental Analytical Laboratories (CAEAL). Suppliers will be notified of the test results in writing.

7 approval and Acceptance Materials that meet the requirements of Section shall be approved by the Department. Materials that do not meet the requirements of Section will be rejected. All suppliers will be notified of the results in writing within 15 working days of submission of samples. January 2019 - 5 - specification No. 1280 . Bidding All products must be pre-approved prior to submission of tenders. The Supplier must clearly indicate which product he or she is bidding on. The Supplier is not allowed to substitute for another product once the contract has been awarded, unless approved by the Department. Material supply .

8 Shipping Calcium chloride in flake form shall be delivered in covered hopper trucks. Liquid dust control, shall be pre-mixed according to the SPECIFICATIONS , and shall be delivered to the site in tank trucks.. Delivery The material shall be delivered to the specified location within 48 hours of notification, excluding Saturdays, Sundays and statutory holidays, unless approved by THE DEPARTMENT. Liquidated damages will be assessed against the Supplier for late delivery after 48 hours notification, unless waived by the Department. The liquidated damages will be the cost incurred by THE DEPARTMENT as a result of the Supplier delay in delivery.

9 THE DEPARTMENT s cost will be calculated as the staff time and equipment charges required to re-work a roadway as a result of a Supplier delay.. Delivery Slip A copy of the delivery slip detailing the chemical being shipped, its percent concentration, and quantity shall be provided to the Department s field representative at the time of delivery. The Supplier shall provide a separate delivery slip for each truckload of product at the time of delivery. If there is no delivery slip, or incomplete information on the slip, the Department reserves the right to reject the product until the slip or complete information is produced by the Supplier.

10 The delivery slip shall be of sufficient size that the field representative can easily record a) the field measured specific gravity and b) the quantity of dust control distributed on separate sections of road. January 2019 - 6 - specification No. 1280 Field Application The Supplier shall apply the applicable chemical on the specified highway(s) and shall work continuously until the work has been completed, unless inclement weather prevents the work. Chemicals shall not be applied during periods of rain, nor if rain is expected within 12 hours of application, nor where the surface to be sprayed is in a saturated condition, nor where, in the opinion of the Engineer, it is impractical to carry out the operation.


Related search queries