SPECIFICATIONS - temperzone.biz

ModelHWP 48 RKSItem No. (Standard/Opposite Hand)509-048-001 / 509-048-011 Cooling capacity (net) to AS/NZS 3823 kWHeating capacity kWElectrical input - kWElectrical input - kWEER / AEER (cooling) / / ACOP (heating) / Unit ControllerUC8 RefrigerantR410 ARefrigerant charge770 gCompressor typerotaryWater connections1/2" male BSPN ominal EWT/EAT on cooling30 C / 27 C db, 19 C wbNominal EWT/EAT on heating20 C / 20 CNominal Water Flow @ EWT LWT = l/sEntering system pressure drop @ nominal kPa (4 psi)Min. water temp. Heat cycle at nominal flow & EAT10 CMin. water temp. Cool cycle at nominal flow & EAT15 CMin. water temp. Cool cycle with water flow control valve5 CMax. EWT Heat cycle at nominal flow & EAT30 CMax. EWT Cool cycle at nominal flow & EAT50 CMin. water flow @ nominal EWT & l/sMax. water pressure excluding hoses3200 kPa (464 psi)Power supply1 ph. 230V ac 50 HzCompressor run amps at rating ACompressor run capacitor40 fdIndoor fan motor size150 WIndoor fan motor (1ph.)

Model HWP 48RKS Item No. (Standard/Opposite Hand) 509-048-001 / 509-048-011 Cooling capacity (net) to AS/NZS 3823 T1 4.3 kW Heating capacity H1 4.6 kW

Tags:

  Specification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SPECIFICATIONS - temperzone.biz

1 ModelHWP 48 RKSItem No. (Standard/Opposite Hand)509-048-001 / 509-048-011 Cooling capacity (net) to AS/NZS 3823 kWHeating capacity kWElectrical input - kWElectrical input - kWEER / AEER (cooling) / / ACOP (heating) / Unit ControllerUC8 RefrigerantR410 ARefrigerant charge770 gCompressor typerotaryWater connections1/2" male BSPN ominal EWT/EAT on cooling30 C / 27 C db, 19 C wbNominal EWT/EAT on heating20 C / 20 CNominal Water Flow @ EWT LWT = l/sEntering system pressure drop @ nominal kPa (4 psi)Min. water temp. Heat cycle at nominal flow & EAT10 CMin. water temp. Cool cycle at nominal flow & EAT15 CMin. water temp. Cool cycle with water flow control valve5 CMax. EWT Heat cycle at nominal flow & EAT30 CMax. EWT Cool cycle at nominal flow & EAT50 CMin. water flow @ nominal EWT & l/sMax. water pressure excluding hoses3200 kPa (464 psi)Power supply1 ph. 230V ac 50 HzCompressor run amps at rating ACompressor run capacitor40 fdIndoor fan motor size150 WIndoor fan motor (1ph.)

2 - full AControl circuit breaker (internal)10 ARunning amps (total system) AMax. running amps (total system) ANet weight 70 kgAccessories:Spring mountssuppliedWater hoses 600mm long, rated 250psi1/2" female BSP, suppliedReplacement filter119-000-098 513x265x13 Condensate lift-pump507-003-009 Optional:SAT-3 Room temperature controller201-000-146 TZT-100 Room temperature controller201-000-350 Refer to temperzone for other options, eg remote sensorsTested in accordance with AS/NZS 382315102 SPECIFICATIONSPROJECTIONNot to ScaleHWP 48 RKS Standard POINT LOADS (kg) W X Y Z 23 13 12 22 DIMENSIONS (mm)Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at SPECIFICATIONS are subject to change without notice due to the manufacturer's ongoing research and development Box500 MIN. CLEARANCE500 MIN. CLEARANCE9046 Right handed model shown hereHWP 48 RKS Opposite HandWXZYAirFlowAirFlow355 Electrical Box9046500 MIN.

3 CLEARANCE500 MIN. CLEARANCE POINT LOADS (kg) W X Y Z 23 12 13 22 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at :Apprvd:Title:Drawing No:Rev:Date: temperzone Ltd 2014DO NOTSCALE - ASKC lient WiringSHEET OF11D291-000-796 Wiring SchematicHWP 36 & 48 RKS ReleaseBMain Earth Symbol updatedN383719-03-16 & SRB now fitted as redesign- numerous DIP switch settingsDIP switchOn/Off1,13,14 OnAll Others OffOffUC8 JUMPER settingsPositionJumperJ1J2 ETH EARTH IFM INDOOR FAN MOTOR K KLIXON RV REVERSING VALVE SRB STATUS RELAY BOARD TB TERMINAL BLOCK TBL2W TERMINAL BLOCK LINK 2 WAY UC8 UNIT CONTROLLER 8 CAP CAPACITOR CCB CONTROL CIRCUIT BREAKER CM COMPRESSOR MOTOR CMC COMPRESSOR CONTACTOR CP2W CONNECTOR PLUG 2 WAY CP4W CONNECTOR PLUG 4 WAY E2RB EXV2 RELAY BOARD FRB FAULT RELAY BOARDS ensors (S) / Transducers (T)NameTypeColourDLDischarge TempSREDSLS uction TempSWHITEICI ndoor CoilSYELLOWHPTHigh PressureTOCR eturn AirSBLACKDTB1TB2 NCP4W1 ETH1CP2W1TB3N1 ETH1TB4N2 CMCTB8 WaterFlow 1 CCBA1-D6-AAB1-D6-BBIf Remote On/Off Optionfitted remove this linkOption for RemoteOn/Off Dry ContactOption for 0-10V toWater Regulating ValveModbus master port foroptional T/stat (TZT100/SAT-3)CMCRVO ption for CondensateFloat Switch (Normallyclosed)TB9 WaterFlow 2 WaterPump 1 WaterPump 2C1-DD1-DIf Condensate Float SwitchOption fitted remove this linkOption forPump VerificationDry ContactsIf Pump VerificationOption fitted removethis linkClient ExternalProtection & IsolationCAP2 TBL2W1M1~CMRCSCAP1 ETH1 GRY (MED-LOW)ORGBLURED (MED-HI)WHT (LOW)BRN (HIGH)M1 ORGIFM1N/OCOMN/CSRBN/OCOMN/CFRBD7-DC6-DC ondensatePumpOption forWater Flow Control ValvePressuresensorsTemp Sensors(Refer to table)

4 UC8 HPTLPTAMB0VA1B10VA2B212 FLTD2D1SC0V0VV20VV1D3 ONEOCICDEIDLSLAUXMEEXV1 EXV2IN#2IN#2IN#1IN#1C2 HTCPC1 HILOCMCSSR2 SSR2 SSR1 SSR1R/VR/VCMCC3 LOWMEDHIGHNLJ1J2C40 VVF50 VVC12DP1SW3SW1SW2 Refer to DIP S/W settingsDisplayModbus slave port for BMS(monitoring or control option)Option for24 VAC/12 VDCcontrolsOptional0-10 VcontrolsTB5L1 TBL2W2N/CCOMN/OCOMN/ORelay 2 Relay 1E2 RBETH3TB6 ACTIVETB7 ACTIVETBL2W3 ETH1 ETH2 KDD temperzone limited 2019003-000-034 10 48 CKSHWP 48 CEKSItem No. - Standard509-048-101509-048-102 Item No. - Opposite Hand509-048-111509-048-112 Cooling capacity (net) to AS/NZS 3823 kWHeating capacity - Electric kWElectrical input - kWElectrical input - kWEER / AEER (cooling) / ControllerUC8 RefrigerantR410 ARefrigerant charge770 gCompressor typerotaryWater connections1/2" male BSPN ominal EWT on cooling30 CNominal EAT on cooling27 C db, 19 C wbNominal Water Flow @ EWT LWT = l/sEntering system pressure drop @ nominal kPa (4 psi)Min.

5 Water temp. Cool cycle at nominal flow & EAT15 CMin. water temp. Cool cycle with water flow control valve5 CMax. EWT Cool cycle at nominal flow & EAT50 CMin. water flow @ nominal EWT & l/sMax. water pressure excluding hoses3200 kPa (464 psi)Power supply1 ph. 230V ac 50 HzCompressor run amps at rating ACompressor run capacitor40 fdIndoor fan motor size150 WIndoor fan motor (1ph.) - full AControl circuit breaker (internal)10 ARunning amps (total system) AMax. running amps (total system) ANet weight 69 kg75 kgAccessories:Spring mountssuppliedWater hoses 600mm long, rated 250 psi1/2" female BSP, suppliedReplacement filter - rated EU2/G2119-000-098 513x265x13 Condensate lift-pump507-003-009 Optional:SAT-3 Room temperature controller201-000-146 TZT-100 Room temperature controller201-000-350 Refer to temperzone for other options, eg remote sensorsTested in accordance with AS/NZS 382315110 SPECIFICATIONSPROJECTIONNot to ScaleHWP 36 CKS/CEKS Standard POINT LOADS (kg) W X Y Z 23 13 12 22 DIMENSIONS (mm)Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at SPECIFICATIONS are subject to change without notice due to the manufacturer's ongoing research and development 36 CKS/CEKS Opposite Hand POINT LOADS (kg) W X Y Z 23 12 13 22 Note: Fan motor can be accessed from panel above, below or sides.

6 No more than two panels at Box500 MIN. CLEARANCE500 MIN. CLEARANCE9046 WXZYAirFlowAirFlow355 Electrical Box9046500 MIN. CLEARANCE500 MIN. CLEARANCEELECTRICALD rawn:Apprvd:Title:Drawing No:Rev:Date: temperzone Ltd 2014DO NOTSCALE - ASKC lient WiringSHEET OF11D291-000-795 Wiring SchematicHWP 36 & 48 CKS ReleaseBMain Earth Symbol updatedN383719-03-16 & SRB now fitted as redesign - numerous DIP switch settingsDIP switchOn/Off1,13,14 OnAll Others OffOffUC8 JUMPER settingsPositionJumperJ1J2 CAP CAPACITOR CCB CONTROL CIRCUIT BREAKER CM COMPRESSOR MOTOR CMC COMPRESSOR CONTACTOR CP2W CONNECTOR PLUG 2 WAY CP4W CONNECTOR PLUG 4 WAY E2RB EXV2 RELAY BOARD FRB FAULT RELAY BOARD ETH EARTH IFM INDOOR FAN MOTOR K KLIXON SRB STATUS RELAY BOARD TB TERMINAL BLOCK TBL2W TERMINAL BLOCK LINK 2 WAY UC8 UNIT CONTROLLER 8CP4W1 ETH1CP2W1 CMCA1-DB1-DIf Remote On/Off Optionfitted remove this linkOption for RemoteOn/Off Dry ContactOption for CondensateFloat Switch (Normallyclosed)C1-DIf Condensate Float SwitchOption fitted remove this linkCAP2M1~CMRCSCAP1 ETH1D1-DGRY (MED-LOW)ORGBLURED (MED-HI)WHT (LOW)BRN (HIGH)

7 M1 ORGIFM1N/OCOMN/CSRBN/OCOMN/CFRBC ondensatePumpOption forWater Flow Control ValveOption for 0-10V toWater Regulating ValveModbus master port foroptional T/stat (TZT100/SAT-3)PressuresensorsTemp Sensors(Refer to table)UC8 HPTLPTAMB0VA1B10VA2B212 FLTD2D1SC0V0VV20VV1D3 ONEOCICDEIDLSLAUXMEEXV1 EXV2IN#2IN#2IN#1IN#1C2 HTCPC1 HILOCMCSSR2 SSR2 SSR1 SSR1R/VR/VCMCC3 LOWMEDHIGHNLJ1J2C40 VVF50 VVC12DP1SW3SW1SW2 Refer to DIP S/W settingsDisplayModbus slave port for BMS(monitoring or control option)Option for24 VAC/12 VDCcontrolsOptional0-10 VcontrolsN/CCOMN/OCOMN/ORelay 2 Relay 1E2 RBCMCTB1TB2 NTB3N1TB4N2TB8 WaterFlow 1 CCB6-AA6-BBTB9 WaterFlow 2 WaterPump 1 WaterPump 2 Option forPump VerificationDry ContactsIf Pump VerificationOption fitted removethis linkTBL2W1D7-DC6-DTB5L1 TBL2W2TB6 ACTIVETB7 ACTIVETBL2W3 ETH1 Client ExternalProtection & IsolationETH1 ETH3 ETH2 KDDDS ensors (S) / Transducers (T)NameTypeColourDLDischarge TempSREDSLS uction TempSWHITEICI ndoor CoilSYELLOWHPTHigh PressureTOCR eturn AirSBLACK temperzone limited 2019003-000-032 10 :Apprvd:Title:Drawing No:Rev:Date: temperzone Ltd 2014DO NOTSCALE - ASKC lient WiringSHEET OF11D291-000-797 Wiring SchematicHWP 36 & 48 CEKS Earth Symbol updated.

8 Dip switch on, was offCFRB &SRB now fitted as redesign - numerous DIP switch settingsDIP switchOn/Off1,3,4,13,14 OnAll Others OffOffUC8 JUMPER settingsPositionJumperJ1J2 ETH EARTH HST HIGH TEMPERATURE SAFETY THERMOSTAT IFM INDOOR FAN MOTOR K KLIXON MST MANUAL SAFETY THERMOSTAT SRB STATUS RELAY BOARD TB TERMINAL BLOCK TBL2W TERMINAL BLOCK LINK 2 WAY UC8 UNIT CONTROLLER 8 CAP CAPACITOR CCB CONTROL CIRCUIT BREAKER CM COMPRESSOR MOTOR CMC COMPRESSOR CONTACTOR CP2W CONNECTOR PLUG 2 WAY CP4W CONNECTOR PLUG 4 WAY E2RB EXV2 RELAY BOARD EH ELECTRIC HEAT EHC ELECTRIC HEAT CONTACTOR FRB FAULT RELAY BOARDS ensors (S) / Transducers (T)NameTypeColourAMBFast Temp SensorSBLACKDLD ischarge TempSREDSLS uction TempSWHITEICI ndoor CoilSYELLOWHPTHigh PressureTOCR eturn AirSBLACKCMCD1-DEHC1t MSTt HSTEHC2C1-DCP4W1CP2W1A1-DB1-DIf Remote On/Off Optionfitted remove this linkOption for RemoteOn/Off Dry ContactOption for CondensateFloat Switch (Normallyclosed)If Condensate Float SwitchOption fitted remove this linkCMCM1~CMRCSCAP1 ETH1 EHCAP2 ETH1 GRY (MED-LOW)ORGBLURED (MED-HI)WHT (LOW)BRN (HIGH)M1 ORGIFM1N/OCOMN/CSRBN/OCOMN/CFRBC ondensatePumpOption forWater Flow Control ValvePressuresensorsTemp Sensors(Refer to table)UC8 HPTLPTAMB0VA1B10VA2B212 FLTD2D1SC0V0VV20VV1D3 ONEOCICDEIDLSLAUXMEEXV1 EXV2IN#2IN#2IN#1IN#1C2 HTCPC1 HILOCMCSSR2 SSR2 SSR1 SSR1R/VR/VCMCC3 LOWMEDHIGHNLJ1J2C40 VVF50 VVC12DP1SW3SW1SW2 Refer to DIP S/W settingsDisplayOption for 0-10V toWater Regulating ValveModbus master port foroptional T/stat (TZT100/SAT-3)Modbus slave port for BMS(monitoring or control option)

9 Option for24 VAC/12 VDCcontrolsOptional0-10 VcontrolsN/CCOMN/OCOMN/ORelay 2 Relay 1E2 RBEHC1 EHC2TB1TB2 NTB3N1TB4N2TB8 WaterFlow 1 CCB6-AA6-BBTB9 WaterFlow 2 WaterPump 1 WaterPump 2If Pump VerificationOption fitted removethis linkTBL2W1D7-DC6-DTB5L1 TBL2W2TB6 ACTIVETB7 ACTIVETBL2W3 ETH1 ETH1 Client ExternalProtection & IsolationETH3 ETH2 DDDK