Example: bachelor of science

Split System Heat Pump Product & Performance Data

XR 132 TWR3018-0601 5 TonsSplit SystemHeat Pump Product & Performance DataPUB. NO. 22-1772-03 SSP-PRC0??-EN 2009 Trane222-1772-03 Features andBenefits Climatuff compressor Efficiency up to SEER HSPF All aluminum Spine Fin coil DuraTuff base, fast complete drain,weather proof WeatherGuard fasteners Tarpaulin gray cabinet Compressor sound insulator Quick-Sess cabinet, easy serviceaccess and refrigerant connectionswith full coil protection Demand Defrost Control withDiagnostics Glossy corrosion resistant finish Internal compressor high/low pressureand temperature protection Start Kit Standard Liquid line filter-drier Comfort R mode approved Service valve cover R-22 refrigerant Compressor sump heat 100% line run test Low ambient cooling to 55 F asshipped Low ambient cooling to 30 F withEDC accessory AY28X084 and TXV Extended warranties available22-1772-033 ContentsFeatures and Benefits2 General Data4 Product Specifications4A-weighted Sound Power Level [dB(A)]

1 Certified in accordance with the Air-Source Unitary Heat Pump equipment certification program which is based on ARI Standard 210/240. 2 Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses.

Tags:

  Performance, Product, System, Pumps, Heat, Split, Split system heat pump product amp performance

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Split System Heat Pump Product & Performance Data

1 XR 132 TWR3018-0601 5 TonsSplit SystemHeat Pump Product & Performance DataPUB. NO. 22-1772-03 SSP-PRC0??-EN 2009 Trane222-1772-03 Features andBenefits Climatuff compressor Efficiency up to SEER HSPF All aluminum Spine Fin coil DuraTuff base, fast complete drain,weather proof WeatherGuard fasteners Tarpaulin gray cabinet Compressor sound insulator Quick-Sess cabinet, easy serviceaccess and refrigerant connectionswith full coil protection Demand Defrost Control withDiagnostics Glossy corrosion resistant finish Internal compressor high/low pressureand temperature protection Start Kit Standard Liquid line filter-drier Comfort R mode approved Service valve cover R-22 refrigerant Compressor sump heat 100% line run test Low ambient cooling to 55 F asshipped Low ambient cooling to 30 F withEDC accessory AY28X084 and TXV Extended warranties available22-1772-033 ContentsFeatures and Benefits2 General Data4 Product Specifications4A-weighted Sound Power Level [dB(A)]

2 ]4 Accessory Description and Usage5 ARI Standard Capacity Rating Conditions5 Model Nomenclature6 Electrical Data7 Dimensions9 Mechanical Specification Options1 0422-1772-03 Product SpecificationsModel No. 12 TWR3018A12 TWR3024A12 TWR3030A12 TWR3036A1 Electrical Data V/Ph/Hz 2200/230/1/60200/230/1/60200/230/1/60200 /230/1/60 Min Cir Ampacity8121319 Max Fuse Size (Amps)15202030 CompressorCLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF RL Amps - LR - - - - Fan FL HP1/151/41/81/6 Fan Dia (inches) Fin Spine Fin Spine Fin Spine Fin Refrigerant R-225/10-LB/OZ5/11-LB/OZ6/07-LB/OZ7/06-L B/OZLine Size - (in.) Gas 35/83/43/47/8 Line Size - (in.) Liquid 31/45/165/163/8 Dimensions H x W x D (Crated) x x x x 3042 x x x x - Shipping201204240298 Weight - Net181183212263 Start ComponentsYESYESYESYESS ound EnclosureYESYESYESYESC ompressor Sump HeatYESYESYESYESO ptional Accessories.

3 4 Anti-short Cycle TimerTAYASCT501 ATAYASCT501 ATAYASCT501 ATAYASCT501 AEvaporator Defrost Control A/CAY28X084AY28X084AY28X084AY28X084 Rubber Isolator KitBAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg-Base & Cap 4" HighBAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" ExtensionBAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT004 Seacoast KitBAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset 5 TAYREFLN1*TAYREFLN2*TAYREFLN2*TAYREFLN3* 1 Certified in accordance with the Air-Source Unitary heat Pump equipment certification program which is based on ARI Standard 210 in accordance with Use only HACR circuit breakers or line lengths - 60', Standard lift - 60' Suction and Liquid Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0.

4 ( denotes latest revision)4 For accessory description and usage, see page * = 15, 20, 25, 30, 40 and 50 foot lineset Sound Power Level [dB(A)]SOUND POWERA-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]MODELLEVEL [dB(A)] : Tested in accordance with ARI Standard (Not listed with ARI)22-1772-03 GeneralDataSPLIT SYSTEMARI Standard Capacity Rating ConditionsARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil,95 F DB air entering outdoor coil.(B) High Temperature Heating 47 F DB, 43 F WB air enteringoutdoor coil, 70 F DB air entering indoor coil.(C) Low Temperature Heating 17 F DB, 15 F WB air enteringoutdoor coil, 70 F DB air entering indoor coil.(D) Rated indoor airflow for heating is the same as for STANDARD 270 RATING CONDITIONS (Noise ratingnumbers are determined with the unit in cooling operation.)

5 Standard Noise Rating number is at 95 F outdoor Description and UsageAnti-Short Cycle Timer Solid state timing device thatprevents compressor recycling until 5 minutes have elapsedafter satisfying call or power interruptions. Use in area withquestionable power delivery, commercial applications, longlineset, Defrost Control SPST Temperature actu-ated switch that cycles the condenser off as indoor coilreaches freeze-up conditions. Used for low ambient coolingto 30 F with Isolators 5 large rubber donuts to isolatecondensing unit from transmitting energy into mountingframe or pad. Use on any application where sound transmis-sion needs to be Start kit Start capacitor and relay to assist compressormotor startup. Use in areas with marginal power supply, onlong linesets, low ambient conditions, Condition Mount Kit Bracket kits to securelymount condensing unit to a frame or pad without removing anypanels.

6 Use in areas with high winds, or on commercial rooftops, SpecificationsModel No. 12 TWR3042A12 TWR3048A12 TWR3060A1 Electrical Data V/Ph/Hz 2200/230/1/60200/230/1/60208/230/1/60 Min Cir Ampacity212532 Max Fuse Size (Amps)354050 CompressorCLIMATUFF CLIMATUFF CLIMATUFF - SCROLLRL Amps - LR - - - 148 Outdoor Fan FL HP1/61/51/5 Fan Dia (inches) Fin Spine Fin Spine Fin Refrigerant R-229/09-LB/OZ9/09-LB/OZ9/08-LB/OZLine Size - (in.) Gas 37/81-1/81-1/8 Line Size - (in.) Liquid 33/83/83/8 Dimensions H x W x D (Crated) x x x x x x - Shipping314315318 Weight - Net278279282 Start ComponentsYESYESYESS ound EnclosureYESYESYESC ompressor Sump HeatYESYESYESO ptional Accessories: 4 Anti-short Cycle TimerTAYASCT501 ATAYASCT501 ATAYASCT501 AEvaporator Defrost Control A/CAY28X084AY28X084AY28X084 Rubber Isolator KitBAYISLT101 BAYISLT101 BAYISLT101 Snow Leg-Base & Cap 4" HighBAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" ExtensionBAYLEGS003 BAYLEGS003 BAYLEGS003 Extreme Condition Mounting KitBAYECMT004 BAYECMT004 BAYECMT004 Seacoast KitBAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset 5 TAYREFLN3*TAYREFLN4*TAYREFLN4*622-1772-0 3 ModelNomenclatureRefrigerant Type2 = R-224 = R-410 ATRANEP roduct TypeW = Split heat PumpT = Split CoolingProduct FamilyZ = Leadership Two StageX = LeadershipR = Replacement/RetailB = BasicA = Light CommercialFamily SEER0 = 10 3 = 13 6 = 161 = 11 4 = 14 8 = 182 = 12 5 = 15 9 = 19 Split System Connections 1-6

7 Tons0 = BrazedNominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60 Secondary FunctionMinor Design ModificationsUnit Parts IdentifierOutdoor Units2 TWR3036A1 000 AARefrigerant Type4 = R-410A2 = R-22 ApplicationTE = Fully ConvertibleTG = Semi ConvertibleTF = Front ReturnTV = VerticalProduct FamilyE = Leadership Variable SpeedP = LeadershipC = Replacement/RetailB = BasicFlow Control3 = Nonbleed TXV4 = FCCV*Feature Identifier0 = Standard UnitF = Air-Tite Nominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = Single PhaseElectrical Connection0 = Pig TailsB = Circuit BreakerD = Pull DisconnectFuture Option Factory Installed Heater Nominal KW ValueMinor Design ModificationsUnit Parts IdentifierNOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years.

8 *Shipped with R-22 FCCVAir Handlers Residential4T E E 3 F 3 6 A 1A A000 Furnace ConfigurationTU = Upflow / HorizontalTD = Downflow / HorizontalTypeD = 80% PremiumX = 90% PremiumNumber of Heating Stages1 = Single Stage2 = Two Stage3 = Three StageCabinet WidthA = " Cabinet WidthB = " Cabinet WidthC = " Cabinet WidthD = " Cabinet WidthHeating Input080 = 80,000 BTUHM ajor Design ChangePower Supply / Fuel9 = 115 Volts / Natural GasF = 115 Volts / Natural Gas with Integrated ifD FilterAirflow Capacity for Cooling36 = 3 Ton Standard PSC MotorH3 = 3 Ton High Efficiency MotorV3 = 3 Ton Variable Speed MotorDraft Inducer Speeds1 = Single Speed2 = Two SpeedV = Variable SpeedMinor Design ChangeService Digit Not OrderableTU D 1 B 0 8 0 A 9 H 3 1A AHigh Efficiency FurnacesRefrigerant Type2 = R-22 4 = R-410 AProduct FamilyT = Premium ( heat Pump or Convertible Coil)C = Standard (Cooling Only)Coil DesignX = Direct Expansion Evaporator CoilProduct FamilyC = Cased A CoilA = Uncased A CoilF = Cased Horizontal Flat CoilCoil Width (Cased / Uncased)

9 A = " / " C = " / " H = "B = " / " D = " / "Refrigerant Line Coupling0 = BrazedNominal Capacity in 000s of BTUsMajor Design ChangeEfficiencyC = Standard S = Hi EfficiencyRefrigerant Control3 = TXV Non-BleedCoil CircuitryH = heat PumpC = Cooling OnlyAirflow ConfigurationA = Upflow OnlyU = Upflow / DownflowH = Horizontal OnlyC = Convertible Upflow, Downflow, Left AirflowM = Convertible Upflow, Downflow, Left or Right AirflowMinor Design ChangeUnit Parts IdentifierHeat Pump /Cooling Coils2T XCB0 3 6 AC 3 HCA A22-1772-032 TWR3018,024,030,036,042A2 TWR3048 AElectricalDataSchematic Diagrams(SEE LEGEND)Printed from D155595P01 Printed from D155596P01822-1772-032 TWR3060 ALEGENDE lectricalDataSchematic DiagramsSYMBOLSP rinted from D155597P0122-1772-03 Dimensions2 TWR3 Outline DrawingNOTE: ALL DIMENSIONS ARE IN MM (INCHES)From Dwg.

10 21D152898 Rev. (32-3/4)724 (28-1/2)651 (25-5/8)5/81/4137 (5-3/8)65 (2-5/8)210 (8-1/4)57 (2-1/4)457 (18)2 TWR3024A21832 (32-3/4)724 (28-1/2)651 (25-5/8)5/85/16143 (5-5/8)65 (2-5/8)210 (8-1/4)57 (2-1/4)457 (18)2 TWR3030A32933 (36-3/4)829 (32-5/8)756 (29-3/4)3/45/16143 (5-5/8)92 (3-5/8)210 (8-1/4)79 (3-1/8)508 (20)2 TWR3036A41943 (37-1/8)946 (37-1/4)870 (34-1/4)7/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)508 (20)2 TWR3042A411045 (41-1/8)946 (37-1/4)870 (34-1/4)7/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)508 (20)2 TWR3048A411045 (41-1/8)946 (37-1/4)870 (34-1/4)1-1/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)508 (20)2 TWR3060A411045 (41-1/8)946 (37-1/4)870 (34-1/4)1-1/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)508 (20)Literature Order NumberFile NumberSupersedesStocking Location04/09 Trane has a policy of continuous Product and Product data improvement and it reserves the right to changedesign and specifications without OptionsGeneralThe 2 TWR3 is fully charged from thefactory for up to 15 feet of piping.