Transcription of Split System Heat Pump Product Data - Trane
1 XL 15i4 TWX51 5 TonsSplit SystemHeat Pump Product DataPUB. NO. 22-1800-15 2 22-1800-15 Features and Benefits Climatuff compressor Efficiency up to SEER and HSPF All aluminum Spine Fin coil WeatherGuard II top shields unit WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant connections with full coil protection DuraTuff base, fast complete drain, weather proof Comfort-R mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection Compressor sump heat Liquid line filter-drier Tarpaulin gray cabinet with anthracite gray badge and cap Low pressure switch Demand Defrost Control with diagnos-tics High pressure switch 018 036 ship with start kit R-410A refrigerant design testing 100% line run test Low ambient cooling to 55 F as shipped Low ambient cooling to 30 F with AY28X084 Extended warranties available22-1800-15 3 ContentsFeatures and Benefits 2 General data 4 Product Specifications 4A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical data 7 Dimensions 12 Mechanical Specification Options 13 4 22-1800-15 Product SpecificationsModel No.
2 1 4 TWX5018B1 4 TWX5024B1 4 TWX5030B1 4 TWX5036B1 Electrical data V/Ph/Hz 2 208/230/1/60 200/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 9 11 15 18 Max Fuse Size (Amps) 15 15 25 30 Compressor CLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF RL Amps - LR Amps - - 58 - Fan FL Amps .92 HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 5/14-LB/OZ 7/02-LB/OZ 8/02-LB/OZ 7/13-LB/OZLine Size - (in.)
3 Gas 3 5/8 5/8 3/4 3/4 Line Size - (in.) Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) x 30 x 33 x x 33 x x x 35 x - Shipping 225 242 283 293 Weight - Net 190 208 239 247 Start Components YES YES YES YESS ound Enclosure YES YES YES YESC ompressor Sump heat YES YES YES YESO ptional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501 AEvaporator Defrost Control A/C AY28X084 AY28X084 AY28X084 AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7*1 Certified in accordance with the Air-Source Unitary heat Pump Equipment certification program which is based on AHRI
4 Standard 210/240. 2 Calculated in accordance with Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0 . ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. General : Rated in accordance with AHRI Standard 270-2008. SOUND POWER LEVEL [dB(A)]A-weighted Sound Power Level [dB(A)]MODEL A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage22-1800-15 5 General DataAHRI Standard Capacity Rating ConditionsAHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil.(B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil.
5 (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil.(D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling opera-tion.) Standard Noise Rating number is at 95 F outdoor Description and UsageAnti-Short Cycle Timer Solid state timing device that prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with Isolators 5 large rubber donuts to isolate con-densing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be Start kit Start capacitor and relay to assist compres-sor motor startup.
6 Use in areas with marginal power supply, on long linesets, low ambient conditions, Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, SpecificationsModel No. 1 4 TWX5042B1 4 TWX5049E1 4 TWX5061G1 Electrical data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 23 28 36 Max Fuse Size (Amps) 40 50 60 Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps - 112 - 117 - 134 Outdoor Fan FL Amps HP 1/8 1/5 1/3 Fan Dia (inches) Spine Fin Spine Fin Spine Fin Refrigerant R-410A 9/14-LB/OZ 13/10-LB/OZ 13/12-LB/OZLine Size - (in.) Gas 3 3/4 7/8 7/8 Line Size - (in.)
7 Liquid 3 3/8 3/8 3/8 Dimensions H x W x D (Crated) 49 x x x x x x - Shipping 300 364 365 Weight - Net 253 314 315 Start Components NO NO NOSound Enclosure YES NO NOCompressor Sump heat YES YES YESO ptional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501 AEvaporator Defrost Control A/C AY28X084 AY28X084 AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3* 2012 Trane 6 22-1800-15 Model NomenclatureRefrigerant Type2 = R-224 = R-410 ATRANEP roduct TypeW = Split heat PumpT = Split CoolingProduct FamilyZ = Leadership Two StageX = LeadershipR = Replacement/RetailB = BasicA = Light CommercialFamily SEER0 = 10 3 = 13 6 = 161 = 11 4 = 14 8 = 182 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons0 = BrazedNominal Capacity in 000s of
8 BTUsMajor Design ModificationsPower Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60 Secondary FunctionMinor Design ModificationsUnit Parts IdentifierOutdoor Units4 TWX5036B1000 AARefrigerant Type4 = R-410A2 = R-22 ApplicationTE = Fully ConvertibleTG = Semi ConvertibleTF = Front ReturnTV = VerticalProduct FamilyE = Leadership Variable SpeedP = LeadershipC = Replacement/RetailB = BasicFlow Control3 = Nonbleed TXV4 = FCCV*Feature Identifier0 = Standard UnitF = Air-Tite Nominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = Single PhaseElectrical Connection0 = Pig Ta ilsB = Circuit BreakerD = Pull DisconnectFuture Option Factory Installed Heater Nominal KW ValueMinor Design ModificationsUnit Parts IdentifierNOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years.*Shipped with R-22 FCCVAir Handlers Residential4 TEE3F36A1AA000 Furnace ConfigurationTU = Upflow/HorizontalTD = Downflow/HorizontalTypeC = CondensingD = Induced DraftE = Electronic IgnitionX = Direct Vent CondensingY = Direct Vent Condensing Variable SpeedHeating Input MBTUH080 = 80,000 BTUHM ajor Design ChangeC = Single Stage R = Two StageAll other = Standard SystemPower Supply and Fuel115 Volt Natural GasAirflow Capacity for CoolingExample.
9 36 = 3 To ns 400 CFM/Ton 400 x 3 To ns = 1200 CFMV3 = 1 1/2 3 To ns, Variable Speed Motor (ICM)V4 = 2 4 To ns, Variable Speed Motor (ICM)V5 = 3 5 To ns, Variable Speed Motor (ICM)Minor Design ChangeService Digit Not OrderableGas FurnacesTUY080R9V3W0 Refrigerant TypeT = R-22R = R-410AC = Cooling onlyFurnace CoilsXA = Uncased A Coil Upflow/DownflowXC = Cased Coil Upflow/Downflow/HorizontalXH = Cased Horizontal OnlyCB = Cased/Brazed Upflow Cooling OnlyUB = Uncased/Brazed Upflow Cooling OnlyCoupling0 = BrazeNominal CapacityNominal Capacity in 000s of BTUsProduct FamilyC = UniversalS = High Efficiency Nonbleed TXVE = High Efficiency Bleed TXVA = Upflow OnlyD = Reverse AirflowRefrigerant Control2 = Cap Tu be3 = Nonbleed TXV4 = Accutron Flow Control/Check Valve (FCCV)5 = Bleed TXVHP = heat Pump00 = Cooling only (7 1/2 to 10 ton)Minor Design ChangeService Digit Not OrderableFurnace CoilsTXC024C4 HPC022-1800-15 7 Electrical DataSchematic Diagrams(SEE LEGEND)4 TWX5018 BPRINTED FROM D156994P02 2012 Trane 8 22-1800-15 Electrical DataSchematic Diagrams(SEE LEGEND)4 TWX5024 BPRINTED FROM D156994P0222-1800-15 94 TWX5030 BPRINTED FROM D156994P02 Electrical DataSchematic Diagrams(SEE LEGEND) 10 22-1800-15 Electrical DataSchematic Diagrams(SEE LEGEND)4 TWX5036 BPRINTED FROM D156994P0222-1800-15 11 Electrical DataSchematic Diagrams(SEE LEGEND)
10 4 TWX5042 BPRINTED FROM D156131P03 TDR relay cycles sump heat off during compressor operation and delays ener-gizing the sump heat for 30 mins after Y call is removed. 12 22-1800-15 Electrical DataSchematic Diagrams(SEE LEGEND)4 TWX5049 EPRINTED FROM D157471P02 TDR relay cycles sump heat off dur-ing compressor operation and delays energizing the sump heat for 30 mins after Y call is 13 Electrical DataSchematic Diagrams(SEE LEGEND)4 TWX5061 GPRINTED FROM D157473P02 TDR relay cycles sump heat off dur-ing compressor operation and delays energizing the sump heat for 30 mins after Y call is removed. 14 22-1800-15 Dimensions4 TWX5 Outline DrawingNOTE: ALL DIMENSIONS ARE IN MM (INCHES)From Dwg.