Example: bachelor of science

Spray-Applied Fire Resistive Material

cafco 300 is a durable, wet mix Spray-Applied FireResistive Material (SFRM) designed to provide fire pro-tection to various floor and roof assemblies, steelbeams, columns, and joists in commercial 300 offers the best fire resistance performanceper unit thickness of any commercial SFRM. This meansless Material is needed to achieve required fire 300 is very cost 300 is applied exclusively by cafco licensed and trained contractors. Our technical staff works closely with building team members to meet all fireprotection COMPLIANCESCAFCO 300 satisfies the requirements of the following: IBC - International Building Code (ICC ESR-1649) New York City - MEA City of Los Angeles NBC - National Building Code of Canada MAJOR SPECIFICATIONSCAFCO 300 complies with the requirements of the following specifications: G

CAFCO 300 is a durable, wet mix Spray-Applied Fire Resistive Material (SFRM) designed to provide fire pro-tection to various floor and roof assemblies, steel

Tags:

  Material, Applied, Fire, Spray, Resistive, Cafco, Spray applied fire resistive material

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Spray-Applied Fire Resistive Material

1 cafco 300 is a durable, wet mix Spray-Applied FireResistive Material (SFRM) designed to provide fire pro-tection to various floor and roof assemblies, steelbeams, columns, and joists in commercial 300 offers the best fire resistance performanceper unit thickness of any commercial SFRM. This meansless Material is needed to achieve required fire 300 is very cost 300 is applied exclusively by cafco licensed and trained contractors. Our technical staff works closely with building team members to meet all fireprotection COMPLIANCESCAFCO 300 satisfies the requirements of the following: IBC - International Building Code (ICC ESR-1649) New York City - MEA City of Los Angeles NBC - National Building Code of Canada MAJOR SPECIFICATIONSCAFCO 300 complies with the requirements of the following specifications: General Services Administration (GSA):AIA/SC/GSA.

2 07811 Department of the Navy NAVFACENGCOM Guide Specification NFGS 07810, Sprayed-On Fireproofing Veterans Administration (VA): H-08-1 ARMY Corps of Engineers CEGS-07811 Environmental Protection Agency (EPA): Regulation 40 Construction Specification Canada (CSC) TEK-AID Factory Mutual ApprovedFIRE TEST PERFORMANCECAFCO 300 has been extensively tested for fireendurance by Underwriters Laboratories (UL) andUnderwriters Laboratories of Canada (ULC) in accordance with ASTM E119 (UL 263, CAN/ULC-S101). These tests have resulted in ratings of up to 4 hours for: Floor Assemblies Beams Joists Columns Roof AssembliesCAFCO 300 has also been tested in accordance withASTM E84 (UL723,CAN/ULC-S102) and has the followingSurface Burning Characteristics Flame PROPERTIESCAFCO 300 is also a thermal insulator.

3 This benefit isimportant in reducing heat loss, particularly when theproduct is applied to the underside of a roof deck. TheR-value added by cafco 300 may allow a reduction inroof 300 Spray-Applied fire Resistive MaterialPhysical PerformanceCharacteristic ASTM Method Standard Performance* Tested Performance**Density E605 15 pcf (240 kg/m3) 15 pcf (240 kg/m3)CombustibilityE136 NoncombustibleNoncombustibleCone CalorimeterE1354 No Flaming or Heat Release No Flaming or Heat ReleaseCohesion/Adhesion E736 150 psf ( kPa) 428 psf ( kPa)Deflection E759 No Cracks or Delaminations No Cracks or DelaminationsBond Impact E760 No Cracks or Delaminations No Cracks or DelaminationsCompressive Strength E761 750 psf ( kPa) 3,100 psf ( kPa)Air Erosion Resistance E859 Less than g/ft2( g/m2) g/ft2( g/m2)Corrosion Resistance E937, Mil.

4 Std. 810 Does Not Promote Corrosion of Steel Does Not Promote Corrosion of Steel Sound Absorption C423 NRC 1" (25mm) on deck and beam Fungal ResistanceG21No Growth After 28 DaysPassed * Standard performance based on General Services Administration AIA/SC/GSA/07811. Refer to UL design for density requirement. For further information refer to the application manual.** Values represent independent laboratory tests under controlled Conductivity (k)* Resistance (R/inch) cafco 300 BTU in/hr ft2 F @ 75 F ( W/mK @ 24 C) *When tested in accordance with ASTM C518 ISOLATEK INTERNATIONAL is registered with theAIA Continuing Education System (AIA/CES)

5 For Further InformationPART 1 Work Provide all labor, materials, equipment and servicesnecessary for, and incidental to, the complete andproper installation of all sprayed fire protection andrelated work as shown on the drawings or wherespecified herein, and in accordance with all applica-ble requirements of the Contract Documents. The Material and installation shall conform to theapplicable building code requirements of all authori-ties having Quality Work shall be performed by a firm with expertise inthe installation of fire protection or similar firm shall be licensed or otherwise approved bythe Spray-Applied fire Resistive Material Before proceeding with the fire protection work.

6 Approval of the proposed Material thicknesses anddensities shall be obtained from the architect andother applicable authorities having Related Section 05100 Structural Section 05300 Metal Section 07200 Section 07270 Section 07812 Intumescent Section 09200 Lath and Section 09900 ReferencesA. ASTM E84 Surface Burning Characteristics ofBuilding ASTM E119 fire Tests of Building Construction ASTM E605 Thickness and Density of Sprayed fire - Resistive Materials applied to Structural ASTM E736 Cohesion/Adhesion of Sprayed fire - Resistive Materials applied to Structural ASTM E759 Effect of Deflection of Sprayed fire - Resistive Materials applied to Structural ASTM E760 Effect of Impact on Bonding ofSprayed fire - Resistive Materials applied toStructural ASTM E761 Compressive Strength of Sprayed

7 fire - Resistive Materials applied to Structural ASTM E859 Air Erosion of Sprayed fire -ResistiveMaterials applied to Structural ASTM E937 Corrosion of Steel by Sprayed fire - Resistive Materials applied to Structural CAN / ULC S101 Standard Methods of fire Testsof Building Construction and CAN / ULC S102 Steiner Tunnel Underwriters Laboratories of Canada (ULC) List ofEquipment and Underwriters Laboratories, Inc (UL) fire Uniform Building Code Standard No. 7-6 (current edi-tion): Thickness and Density Determination for Spray-Applied fire AWCI Publication: Technical Manual 12-A StandardPractice for the Testing and Inspection of Field- applied Sprayed fire Resistive Materials.

8 AnAnnotated Manufacturer s Data: Submit Manufacturer s specifi-cation, including certification as may be required toshow Material compliance with Contract Test Data: Independent laboratory test results shallbe submitted for all specified performance Delivery, Storage and Deliver materials to the project in manufacturer sunopened packages, fully identified as to tradename, type and other identifying data. Packagingshall bear the UL labels for fire hazard and fire -resistance classifications. Store materials above ground, in a dry location, pro-tected from the weather.

9 Damaged packages foundunsuitable for use should be rejected and removedfrom the Project When the prevailing outdoor temperature at thebuilding is less than 40 F (4 C), a minimum sub-strate and ambient temperature of 40 F (4 C) shallbe maintained prior to, during, and a minimum of 24hours after application of Spray-Applied fire resistivematerial. If necessary for job progress, GeneralContractor shall provide enclosures and heat tomaintain proper temperatures and humidity General Contractor shall provide ventilation to allowproper drying of the sprayed fire protection duringand subsequent to its In enclosed areas.

10 Ventilation shall not be less than 4complete air changes per All fire protection work on a floor shall be completedbefore proceeding to the next The Contractor shall cooperate in the coordinationand scheduling of fire protection work to avoiddelays in job 2 Acceptable Manufacturers. The Spray-Applied fireresistive Material shall be manufactured under theCAFCO brand name, by authorized Materials shall be cafco 300, (UL/ULC designation:Type 300) applied to conform to the drawings, speci-fications and following test Deflection: When tested in accordance with ASTME759, the Material shall not crack or delaminatewhen the non-concrete topped galvanized deck towhich it is applied is subjected to a one time verticalcenterload resulting in a downward deflection of1/120th of the Bond Impact.


Related search queries