Example: quiz answers

STANDARD DAY TANKS - Pryco Inc.

DT-1 Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 The Content Herein Is Subject To Change Without Notice. DOUBLE WALL TANKS A totally enclosed outer shell may be added resulting in a double wall construction. Both the inner and the outer TANKS are vented separately and each are pressure tested. When enclosing a U/L Listed day tank an additional emergency vent is added to the double wall containment area the same size as the inner tank. (The U/L Listing is Secondary Containment Aboveground Tank for Flammable Liquids File MH12807.) All day TANKS (10 gallon and more capacity) excluding Trim day TANKS have all threaded connections located on the tank top (except the tank overflow and the double wall drain and vent).

DT-2 P.O. Box 108 Mechanicsburg IL 62545 Phone -217 / 364-4467 Fax -217 / 364-4494 The Content Herein Is Subject To Change Without Notice. See Page DT-1 For U/L Listed Emergency Vent Sizing. STANDARD DAY TANK REFERENCE DATA

Tags:

  Standards, Tanks, Standard day tanks

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of STANDARD DAY TANKS - Pryco Inc.

1 DT-1 Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 The Content Herein Is Subject To Change Without Notice. DOUBLE WALL TANKS A totally enclosed outer shell may be added resulting in a double wall construction. Both the inner and the outer TANKS are vented separately and each are pressure tested. When enclosing a U/L Listed day tank an additional emergency vent is added to the double wall containment area the same size as the inner tank. (The U/L Listing is Secondary Containment Aboveground Tank for Flammable Liquids File MH12807.) All day TANKS (10 gallon and more capacity) excluding Trim day TANKS have all threaded connections located on the tank top (except the tank overflow and the double wall drain and vent).

2 The inner tank drain is located on the tank top under the removable cover. STANDARD DAY TANKS STANDARD FEATURES Removable 6 " Square Inspection Plate w/Gasket Fuel Level Gauge Heavy Duty Float Switch Press-to-Test Switch "Pump Running" Indicator Light 1/3 hp Thermally Protected 120vac 1ph 60hz Motor 2 gpm Bronze Gear Pump w/Stainless Steel Shafts Threaded Pipe Connections for: Engine Supply and Return (w/Drop Tubes) Atmospheric Vent Emergency Vent (If U/L Listed) Pump-To-Tank Inlets and Outlets (w/Drop Tubes) Overflow (Normally Back to Main Tank) Tank Drain (w/Drop Tube) Extra 2 Connection Ports (2 ports in top of 10 thru 150 gallon TANKS [one will be used for option 301, if included].)

3 1 port in tank top of 200 gallons and above) - STANDARD design TANKS only If Double Wall Secondary Containment Add: An Atmospheric Vent An Emergency Vent (If U/L Listed) Removable Top Cover Epoxy Coating Inside Pryco (Medium) Gray Exterior Paint (or an In-dustrial Color of Choice) TANK VENTING Each tank (and double wall containment area if applicable) has a 2 Atmospheric Vent. If the tank is U/L Listed an Emergency Vent is added. The size of the U/L Emergency Vent depends upon the wetted surface area of the tank. The wetted surface of the day TANKS shown within this section has been calculated and the U/L vent size is shown below.

4 If the tank is U/L Listed and double walled the same size Emer-gency Vent is also added to the double wall con-tainment area. 2 - 10 50 Gallons 3 - 60 150 Gallons 4 - 200 500 Gallons and 6 - 600 1000 Gallons Pryco s STANDARD Day TANKS are available in either a U/L Listed (Label #142) or a basic (non-U/L Listed) design. In addition to the STANDARD features listed below U/L Listed TANKS have additional internal reinforcement an emergency vent properly sized to the tank and a U/L Listed label (File #MH12807 - Aboveground Tank for Flammable Liquids). Pryco TANKS are fabricated of heavy gauge steel by certified welders and are tested accord-ingly.

5 Catalog Number (12/2012) DT-2 Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 The Content Herein Is Subject To Change Without Notice. See Page DT-1 For U/L Listed Emergency Vent Sizing. STANDARD DAY TANK REFERENCE DATA TANK SIZE ( GAL) STANDARD SINGLE WALL DAY TANKS STANDARD DOUBLE WALL DAY TANKS BASIC DESIGN U/L LISTED SINGLE WALL DRAWING REF BASIC DESIGN U/L LISTED DOUBLE WALL DRAWING REF MODEL WT * (Lbs) MODEL WT *(Lbs) BASIC & U/L 150% R/B ** 200% R/B ** MODEL WT * (Lbs) MODEL WT * (Lbs) BASIC & U/L 150% R/B ** 200% R/B ** SIZE CATEGORY A DAY TANKS 5 PY5 60 PY5UL 75 CALL CALL CALL PY5DW 160 PY5 ULDW 175 CALL CALL CALL 10 PY10 85 PY10UL 100 DT-9 DT-25 DT-28 PY10DW 170 PY10 ULDW 195 DT-12 DT-25 DT-28 15 PY15 95 PY15UL 110 DT-9 DT-25 DT-28 PY15DW 200 PY15 ULDW 215 DT-12 DT-25 DT-28 25 PY25 105 PY25UL 120 DT-9 DT-25 DT-28 PY25DW 230 PY25 ULDW 245 DT-12 DT-25 DT-28 SIZE CATEGORY B DAY TANKS 50 PY50 193 PY50UL 197 DT-10 DT-26 DT-29 PY50DW 367 PY50 ULDW 371 DT-13 DT-26 DT-29 60 PY60 220 PY60UL 226 DT-10 DT-26 DT-29 PY60DW 420 PY60 ULDW 428 DT-13 DT-26 DT-29 75 PY75 236 PY75UL 243 DT-10 DT-26 DT-29 PY75DW 454

6 PY75 ULDW 461 DT-13 DT-26 DT-29 100 PY100 257 PY100UL 263 DT-10 DT-26 DT-29 PY100DW 502 PY100 ULDW 509 DT-13 DT-26 DT-29 150 PY150 302 PY150UL 309 DT-10 DT-26 DT-29 PY150DW 604 PY150 ULDW 611 DT-13 DT-26 DT-29 SIZE CATEGORY C DAY TANKS 200 PY200 427 PY200UL 438 DT-11 DT-27 DT-30 PY200DW 882 PY200 ULDW 895 DT-14 DT-27 DT-30 275 PY275 495 PY275UL 505 DT-11 DT-27 DT-30 PY275DW 1111 PY275 ULDW 1124 DT-14 DT-27 DT-30 300 PY300 500 PY300UL 510 DT-11 DT-27 DT-30 PY300DW 1124 PY300 ULDW 1137 DT-14 DT-27 DT-30 400 PY400 572 PY400UL 583 DT-11 DT-27 DT-30 PY400DW 1285 PY400 ULDW 1297 DT-14 DT-27 DT-30 500 PY500 613 PY500UL 624 DT-11 DT-27 DT-30 PY500DW 1396 PY500 ULDW 1409 DT-14 DT-27 DT-30 600 PY600 653 PY600UL 663 DT-11 DT-27 DT-30 PY600DW 1489 PY600 ULDW 1501 DT-14 DT-27 DT-30 700 PY700 700 PY700UL 710 DT-11 DT-27 DT-30 PY700DW 1622 PY700 ULDW 1635 DT-14 DT-27 DT-30 800 PY800 743 PY800UL 753 DT-11 DT-27 DT-30 PY800DW 1897 PY800 ULDW 1910 DT-14 DT-27 DT-30 900 PY900 786 PY900UL 809 DT-11 DT-27 DT-30 PY900DW 2025 PY900 ULDW 2056 DT-14 DT-27 DT-30 1000 PY1000 818 PY1000UL 841 DT-11 DT-27 DT-30 PY1000DW 2110 PY1000 ULDW 2141 DT-14 DT-27 DT-30 * WEIGHTS ARE APPRXIMATE DEPENDING UPON ATTACHED OPTIONS, ETC.

7 **1R/B RUTURE BASIN DT-3 Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 The Content Herein Is Subject To Change Without Notice. SECONDARY CONTAINMENT DOUBLE WALL TANKS and RUPTURE BASINS All day TANKS may be set within a Rupture Basin or Open Top Dike. Rupture basins are available with a minimum capacity of either 150% or 200% of the inner tank (the vessel where fuel is normally stored). The inner tank is used to determine rupture basin size. Single wall day TANKS may be set within either a 150% or a 200% rupture basin whereas those with double wall construction will only fit within a 200% minimum capacity rupture basin.

8 Weatherproof rupture basins are also availa-ble see Option 335 on page OP-20. USES OF MANUAL TANKS Manual TANKS take on a variety of roles other than that of a typical day tank. For example: Larger Manual TANKS are often used as the system s main storage tank. In this role they are normally used in conjunction with a day tank with pump and controls. (Consider a U/L Listed double walled version.) Smaller versions may be used as a wall-mounted dry sump for automatic engine lubrication. The only restriction is like all TANKS they should not be utilized as a pressurized vessel. Pryco MANUAL Day TANKS are identical to STANDARD Day TANKS but do not have a pump motor and a control system.

9 This is to facilitate possible future conversion to a STANDARD pumping system by adding a few parts. (All Manual day TANKS have a remova-ble cover.) Like all of Pryco s TANKS Manual day TANKS are available as either a basic non-U/L Listed configuration or a U/L Listed one (Label 142 File #MH12807 - Above-ground Tank for Flammable Liquids). Both include the STANDARD Features listed below. The U/L Listed TANKS also include additional internal reinforcement an emergency vent properly sized to the tank and a U/L Listed label. Pryco TANKS are fabricated of heavy gauge steel by certified welders and are tested ac-cordingly. MANUAL DAY TANKS A 300-gallon U/L Listed Manual Double Wall Day Tank.

10 STANDARD FEATURES MANUAL TANKS Removable 6 " Square Inspection Plate w/Gasket Fuel Level Gauge Threaded Pipe Connections for: Engine Supply and Return (w/Drop Tubes) Atmospheric Vent Emergency Vent (If U/L Listed) Pump-To-Tank Inlets and Outlets (w/Drop Tubes) Overflow (Normally Back to Main Tank) Tank Drain (w/Drop Tube) Extra 2 Connection Manual Tank Fill (2 ) w/Lockable Fill Cap If Double Wall Secondary Containment Add: An Atmospheric Vent An Emergency Vent (If U/L Listed) Removable Top Cover Epoxy Coating Inside Pryco (Medium) Gray Exterior Paint (or an Industrial Color of Choice) DT-4 Box 108 Mechanicsburg IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494 The Content Herein Is Subject To Change Without Notice.


Related search queries