Example: barber

Starvert iV5 - AVETOP

Automation EquipmentLeader in Electrics & AutomationSSttaarrvveerrtt iiVV55 High Precision &Torque ControlLG Vector Inverter ~~3377kkWW 33 PPhhaassee 220000~~223300VV,, ~~222200kkWW 33 PPhhaassee 338800~~446600VV" The optimum solution " The vector control LG Starvert iV5 seriesprovides a full satisfaction for all the needs." The optimum solution " The vector control LG Starvert iV5 seriesprovides a full satisfaction for all the Specification 11 Terminal Function16 Function Codes Table 26 Dimension29 Basic configuration14 Loader Use06 Model & Type09 Wiring13I/O Board15 Shifts between each groups andcodes in the Loader 24 Braking Unit andResistor28 Fault Solution and Check We guarantee, your satisfaction Will bebeyond your expectation LG Starvert iV5 series realizes the highprecision vector control in entireoperatio

Automation Equipment Leader in Electrics & Automation Starvert iV5 High Precision &Torque Control LG Vector Inverter 5.5~37kW 33Phase 2200~230V, 55.5~220kW 33Phase 3380~460V

Tags:

  Starvert iv5, Starvert

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Starvert iV5 - AVETOP

1 Automation EquipmentLeader in Electrics & AutomationSSttaarrvveerrtt iiVV55 High Precision &Torque ControlLG Vector Inverter ~~3377kkWW 33 PPhhaassee 220000~~223300VV,, ~~222200kkWW 33 PPhhaassee 338800~~446600VV" The optimum solution " The vector control LG Starvert iV5 seriesprovides a full satisfaction for all the needs." The optimum solution " The vector control LG Starvert iV5 seriesprovides a full satisfaction for all the Specification 11 Terminal Function16 Function Codes Table 26 Dimension29 Basic configuration14 Loader Use06 Model & Type09 Wiring13I/O Board15 Shifts between each groups andcodes in the Loader 24 Braking Unit andResistor28 Fault Solution and Check We guarantee.

2 Your satisfaction Will bebeyond your expectation LG Starvert iV5 series realizes the highprecision vector control in entireoperational area and its highly precisespeed control guarantees a superb controlstability in the elevator Starvert iV5 series features the versatile and user-friendlyinterface and extended functional innovation."LG inverter is to be evolvedthrough our state-of-the-arttechnologies from now on" LG Starvert iV5 series features the versatile and user-friendlyinterface and extended functional innovation."LG inverter is to be evolvedthrough our state-of-the-arttechnologies from now on" 05 Features LG Inverter iV5 SeriesAutotuningIn the application which requires a high torque at low speed, theelectrical parameters of motor should be properly set for an Vector Controlled Inverter of iV5 has two types of autotuning, whichare standstill type and rotation type, respectively.

3 Standstill type Autotuning This unique technology of LG allows the autotuning operation to beperformed even with the motor shaft directly connected to the , this standstill type autotuning is very useful in the liftapplication because it does not require removal of brake couplingconnected to the motor. Rotation type AutotuningThis type of autotuning has been widely used for the vector controlinverter. As the name implies, this requires the motor shaft to be freeof the coupling for a proper communication interfacesiV5 provides various communication interface such as RS 485,DeviceNET, Profibus-DP and Modbus-RTU.

4 When LG PLC is used as anupper level controller, it can be easily interfaced to the compliancesAll Starvert iV5 series comply with cUL and UL (Type1) function card (ENC_DIV,DIAO and ELIO)Option card for the encoder pulse division (ENC_DIV) supports theencoder with open collector output and can divide the encoder pulse upto 1 input and Analog signal output card (DIAO) can receive thebinary speed command from PLC or other upper level controller and has4 channels of analog signal card enables the lift application software to be available for anoptimized lift Model & TypeApplicable Motor ( ) (10HP) 11kW (15HP) 15kW (20HP) (25HP) 22kW (30HP) 30kW (40HP) 37kW (50HP) 45kW (60HP) 55kW (75HP) 75kW (100HP) 90kW (120HP) 110kW (150HP) 132kW (175HP) 220kW (300HP)

5 SV055iV5-2 DBSV075iV5-2DB SV110iV5-2 DBSV150iV5-2DB SV185iV5-2 DBSV220iV5-2 DBSV300iV5-2 DBSV370iV5-2 DBSV055iV5-4 DBSV075iV5-4 DBSV110iV5-4 DBSV150iV5-4 DBSV185iV5-4 DBSV220iV5-4 DBSV300iV5-4SV370iV5-4SV450iV5-4SV550iV5 -4SV750iV5-4SV900iV5-4SV1100iV5-4SV1320i V5-4SV1600iV5-4SV2200iV5-4200V Series400V SeriesInverter typeInput power specificationRated capacity Output power specificationOperation frequency and rated output Bar-codeSerial numberDisplays if DB circuit is built in Input voltage specificationSTARVERTM aximum applicable motor capacityiV5 Series07 Standard Specification 200V Class Specifications Type : SV[ ][ ][ ]iV5-2(DB)Maximum applicable [HP]motor ranges * Note1)[kW]Capacity[kVA] * Note2)Rated outputRated current [A] Output speedOutput voltageRated inputVoltage Frequency Weight [Kg(Ibs)]055075 ~ 3600rpm (Vector control)200 ~ 230V * Note3)3 200 ~ 230V (-15% ~ +10%) 50 ~ 60Hz ( 5%) 14(31) 14(31) 28(62) 28(62)28(62)28(62) 43(93) 43(93) 400V Class Specifications Type.

6 SV[ ][ ][ ]iV5-4(DB)Maximum applicable [HP]motor ranges [kW]Capacity[kVA]Rated outputRated current [A] Output speedOutput voltageRated inputVoltage Frequency Weight [Kg(Ibs)]055075 ~ 3600rpm (Vector)380 ~ 460V * Note3)3 380 ~ 460V (-15% ~ +10%) 50 ~ 60Hz ( 5%) 14(31) 14(31) 28(62) 28(62)28(62)28(62) 45(99) 45(99)Type : SV[ ][ ][ ]iV5-4(DB)Maximum applicable [HP]motor ranges [kW]Capacity[kVA]Rated outputRated current [A] Output speedOutput voltageRated inputVoltage Frequency Weight [Kg(Ibs)]4505507509001100132016002200607 5100120150175215300455575901101321602207 0851161401702002503299111015218322326432 54320 ~ 3600rpm (Vector)380 ~ 460V * Note3)3 380 ~ 460V (-15% ~ +10%) 50 ~ 60Hz ( 5%) 63(139) 63(139) 68(150) 98(216) 98(216) 122(269) 122(269) 175(386)*Note1)

7 It represents the output capacity 05 maximum applicable motor in case LG-OTIS 4pole motor is used.*Note2) Rated capacity ( = 3VI) is calculated based on 220V for 200V class, 440V for 400V class.*Note3)Maximum output voltage cannot be generated greater then specified input voltage. 08 Standard SpecificationsSpeed settingInputOutputAnalog input Digital input Analog output Digital outputOpen collector output Protection function Installation environmentAmbient temperatureAmbient humidityCooling method Altitude / VibrationEnvironmentDigital settingMulti-step-speed setup by digital inputAnalog input setting of -10~10V or 4~20mASetting by options3 Channels (AI1, AI2, AI3)-10 ~ 10V, 4 ~ 20mA, 10 ~ 0V, 20 ~ 4mA, motor NTC (selectable)

8 Selectable among 9 different multi-function analog inputsFX, RX, BX, RST, P1 ~ P7 Multi function input terminal (P1~P7) can be selected among 27 (AO1, AO2)-10 ~ 10V outputSelective among 31 multi-function analog output functionsMulti function digital output: 2channels (1A-1B, 2A-2B)Fault digital output: 1channel (30A-30C, 30B-30C)1channel (OCI/EG)Over current, Over/Low voltage, Inverter overheat, Inverter thermal sensor open, Motor over heat, Motor thermal sensor open, Over speed, IGBT gate blocking (BX), Fuseopen, Trip by unusual external signal, Encoder error, Communication error, Electronicthermal, Stall prevention (V/F), Over load(V/F), Inverter over loadIndoor, free of corrosive gas and direct sunlight-10 ~ 40C (Non frozen condition)Below RH90% (Dew free)Forced cooling by FANB elow 1000 meters/ above sea level (= )

9 Common SpecificationsResponse speedtorque control V / F patterntorque BoostTime setup Combination Pattern Control type Frequency / Speed control accuracyFrequency / Speed resolutionBraking typeBraking torqueBraking resistorCircuit typeItemIGBT adopted voltage type inverterSpecificationSpeed sensor use vector type control Open loop control: V/F control (90-220kW)Analog: of maximum command speed (25 10 C)Digital: of maximum command speed (0~40 C)Analog: of maximum command speedDigital: of maximum command speed50Hz3% Linear, Square, User V/FManual torque boost(0-20%), Automatic torque sec (Time unit can be set)4 combined of Acc/Dec eleration timeLinear, S-CurveDynamic braking using external resistor150% An external braking resistor is requiredVectorV / FSpeedACC/DECB raking Control 09 Wiring SV 055, 075, 110, 150, 185, 220 iV5-2(DB)SV 055, 075, 110, 150, 185, 220 iV5-4(DB)MCCB MC24V 3phase ACinput(220V/440V50/60Hz)

10 ACRM ulti function input1 Multi function input2 Multi function input3 Forward run/Stop commandReverse run/Stop commandEmergency stopFault resetMulti function input4 Multi function input5 Multi function input6 Multi function input7 Multi function inputVariable resistor 10 , 1/2 WAnalog input(-10V~10V)(4~20mA)(0V~10)(4~20mA)Mo tor NTCC ommon terminalStandard voltageAnalog input1 Analog input2 Analog input3 Common terminalAnalog output1 Analog output2 Common outEncoder output-A PhaseEncoder output common terminalEncoder output-B PhaseEncoder output common terminalMulti function open collector output(24V, 50mA)Multi function digital output(~AC 250V, 1A)(~DC 30V, 1A)Fault digital output(~AC 250V, 1A)(~DC 30V, 1A)Analog output(-10~10V)Shielded cableBrake resistor(option)Encoder( line drive)RSTGUVWGP3(ATO)P4(FHM)P5(BAT)P6(BR C)P7(MCC)CMVREFAI1AI2AI35GP1(MM0)P2(MM1)


Related search queries