SETTINGTHE STANDARDFOR THE INDUSTRYSTONEMANROOF FLASHINGSACORN ENGINEERINGF amily of CompaniesEst. 1954 ELMDOR/ STONEMAN MANUFACTURING founded on the principle of design and production of the finest quality sheet metal fabrication. STONEMAN , with a tradition of innovation and unique patented product design, backed with 50+ years ofexperience, has historically set quality standards in the a supportive national sales network, as well as strategically located warehouses, Elmdor/Stonemanis dedicated to the development and distribution of quality products for the building is a division of Acorn Engineering COMMITMENT QUALITY SERVICE The counterflashing is secured to the vent pipe by three vandal-resistant screws. The top recess is partially filled with back-upfiller, such as polyethylene foam or a dry, non-asphalytic mate-rial, such as oakum.

1100 1100-4 FLASHINGS These flashing assemblies are recommended for flashing all pipes where they pass through the roof. Flashings:The vari-pitch boot of the flashing

Tags:

  Flashings, Stoneman

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of STONEMAN - Water Solutions Marketing

1 SETTINGTHE STANDARDFOR THE INDUSTRYSTONEMANROOF FLASHINGSACORN ENGINEERINGF amily of CompaniesEst. 1954 ELMDOR/ STONEMAN MANUFACTURING founded on the principle of design and production of the finest quality sheet metal fabrication. STONEMAN , with a tradition of innovation and unique patented product design, backed with 50+ years ofexperience, has historically set quality standards in the a supportive national sales network, as well as strategically located warehouses, Elmdor/Stonemanis dedicated to the development and distribution of quality products for the building is a division of Acorn Engineering COMMITMENT QUALITY SERVICE The counterflashing is secured to the vent pipe by three vandal-resistant screws. The top recess is partially filled with back-upfiller, such as polyethylene foam or a dry, non-asphalytic mate-rial, such as oakum.

2 It is then topped with epoxy compound(epoxy compound and partial filler not furnished).The joint between the flashing and the vent pipe is sealed andmade watertight with epoxy compound and permits expansionand contraction of the vent pipe, or minor movement of the roofdue to snow or rain loads, without disturbing the seal. Themovement is not transmitted to the flashing and the vital bondbetween the flashing and the roofing felts is permanently reinforcing in boot prevents puncturing during installationand service. Conical shape permits installation on roofs withvariable pitch to 20 degrees. Round skirt provides uniform flashing engagement with rooffelts. Available in 6 , 8 and 10 widths, which provides adequateflashing area for all types of roof top prevents gravity entry of gravel, sand, dirt, criteria for all STONEMAN vandal-resistant hoods providea minimum of 2 to 1 open area compared to the cross-sectionalarea of the vent pipe.

3 Pipe stops prevent reduction of this areaduring Head socket type set screws securely attach the vandal-resistant hood to the barrier provides a solid section opposite each ventslot, effectively preventing entry of sticks, open area on bottom of hood prevents frost reinforcing in boot prevents puncturing during installationand service. Conical shape permits installation on roofs withvariable pitch to 20 degrees. flashings are made from full weight 4lb. & 6lb. lead to suit allinstallation in caulk OF STORM-TITE FLASHINGSE lmdor/ STONEMAN 1100-41100 FLASHINGST hese flashing assemblies are recommended for flashingall pipes where they pass through the roof. flashings :The vari-pitch boot of the flashing will fit allangles up to 20 degrees. flashings with 6 skirts are suit-able where a solid base is provided, such as poured con-crete roofs.

4 The 8 or 10 skirts are preferred for wood, tileand steel decking, or wherever the larger flashing area isdesired. The 4 lb. weight is suitable for general 6 lb. weight is preferred in industrial areas where cor-rosive fumes are prevalent, costal areas where salt air isa problem and wherever maximum protection is Installation:Provide vent pipe of correct heightfor flashing assembly to be used. When roofing felts areapplied drop flashing in place and mop in in accor-dance with the roofing specifications. Install counterflash-ing and seal upper annular space with epoxy and Construction: STONEMAN (Semco) seam-less lead flashings are manufactured from chemical sheetlead that meet ASTM B-29 and Federal Specification QQ L 20f, and grade C. All conical flashings are fur-nished with a galvanized steel reinforced boot.

5 The neckis sealed to the pipe, tube or conduit and covered withpractical cast iron counter flashing secured to the pipewith vandal-resistant screws. The upper annular piece issealed with epoxy compound. This provides for expan-sion and contraction of flashed pipe without disturbingthe flashing. When properly installed these features giveassurance that storm and internal wastewater never enterthe Specification: Provide, on each roof penetration. ElmdorStoneman #1100 lead flashing. Flashing shall be 4 lb. seamless lead withsteel reinforced boot and shall permit installation on roofs with up to a 20degree LEAD FLASHING WITHCAST IRON COUNTERFLASHING Recommended for flashing all standard pipe size andcast iron roof penetrations from 1/2" to 12". Seamless lead flashing with steel reinforced bootprovides for a watertight installation.

6 Complies with ASTM B-29 and QQL-20F, Grade C. Cast iron caulk type counterflashing. Set screw connects directly to roof Specification: Provide, on each roof penetration. ElmdorStoneman #1100-4 lead flashing/counterflashing assembly. Flashing shallbe 4 lb. seamless lead with steel reinforced boot and shall permit installa-tion on roofs with up to a 20 degree pitch. Counterflashing shall be castiron set screw type and be attached directly to roof , dimensions and products described are subject to change without reserves the right to furnish materials of current design for all orders. Do not rough-in without certified Manufacturing1100-5 SEAMLESS LEAD FLASHING W/ CAST IRONCOUNTERFLASHING & VANDAL FLASH HOOD For flashing all standard pipe size and cast iron roofpenetrations from 1-1/4" to 6". Seamless lead flashing with steel reinforced bootprovides for a watertight installation.

7 Complies with ASTM B-29 and QQL-20F, Grade C. Cast iron caulk type counterflashing with cast iron Vandal Flash Hood. Set screw connects directly to roof penetration. Vandal Flash Hood prevents entry of foreign materialinto the vent Specification: Provide, on each roof penetration. ElmdorStoneman #1100-7 lead flashing/counterflashing assembly with cast iron caulktype counterflashing and cast iron Vandal Flash Hood. Flashing shall be 4 lead with steel reinforced boot and shall permit installation on roofswith up to a 20 degree pitch. Combination counterflashing and VandalFlash Hood shall be cast iron set screw type and be attached directly toroof LEAD FLASHINGWITH VANDAL FLASH HOOD Recommended for flashing all standard pipe sizeand cast iron roof penetrations from 1-1/4" to 6". Seamless lead flashing with steel reinforced boot provides for a watertight installation.

8 Complies with ASTM B-29 and QQL-20F, Grade C. Cast iron caulk type counterflashing with cast iron Vandal Flash Hood. Set screw connects directly to roof penetration. Vandal Flash Hood prevents entry of foreign materialinto the vent pipeGuide Specification: Provide, on each roof penetration. ElmdorStoneman #1100-5 lead flashing/counterflashing assembly with Vandal FlashHood. Flashing shall be 4 lb. seamless lead with steel reinforced boot andshall permit installation on roofs with up to a 20 degree pitch. Combinationcounterflashing and Vandal Flash Hood shall be cast iron set screw typeand be attached directly to roof / 915910 Designs, dimensions and products described are subject to change without reserves the right to furnish materials of current design for all orders. Do not rough-in without certified FLASHC ommercial and industrial buildings are often designedwith provisions for future mounted equipment.

9 The instal-lation of Future/Multi-Flash assemblies during originalconstruction allows for the future installation of multipleservice lines, avoiding the problems inherent in cuttingthrough finished roofs and installing makeshift departing from the traditional one roof penetrationone flashing concept, roof penetrations and the numberof flashings required are reduced, resulting in efficientand economical installations. For flashing multiple roof penetrations ranging in size from 1/8" outside diameter to 6"nominal standard pipe sizes Counterflashing cap and adapters of UV resistant PVC Seamless lead flashing with steel reinforcedboot provides for a watertight installation. Complies with ASTM B-29 and QQL-20F, Grade C Multi-Flash Adapters, field solvent cemented to the counterflashing cap for on the job versatilityGuide Specification: Provide Elmdor STONEMAN #910 lead flash-ing with Future Flash counterflashing cap.

10 Flashing shall be 4 lb. seamlesslead with 6 skirt and steel reinforced boot. Provide 915 Multi-Flash adaptersto be sized to fit tubing, conduit and pipe penetrations. All flashings shallbe installed in accordance with manufacturer s recommendations andflashed in accordance with the recommendations of the roofing ADAPTERS 915 Multi-Flash adapters are used in conjunction withthe 910 Future/Multi-Flash. The PVC adapter utilizes acompression gasket to achieve a snug fit for a varietyof pipe sizes. Once the location and holes for the pipepenetrations are determined on the 910 cap theappropriately sized adapter is used. This counterflash-ing/adapter is used to maintain the Water -tightness ofthe flashed roof penetration. See the chart below or inthe trade price guide for the adapter sizes ( Future Flash Pictured )SPSEIMCEMTNCTNHCIRCTSWCIXHCI1/8 A4A43/16 A41/4 A3A4A43/8 A2A3A41/2 A2 / A3A2A2A3A35/8 A33/4 A2A2A2A2A27/8 A21 A1A1A1A11-1/8 A11-1/4 B2B2B2B2 / B31-3/8 B2 / B31-1/2 B1B1B1B2B11-5/8 B22 C1C1C1C2C1C1C12-1/8 C2 Designs, dimensions and products described are subject to change without reserves the right to furnish materials of current design for all orders.