Stratix 5700 - Rockwell Automation

Stratix 5700. Industrial Managed ethernet Switch Features and Benefits: Advanced Networking Features Integrated Device Level Ring (DLR). connectivity helps optimize the network architecture and provide consolidated network diagnostics Integrated Network Address Translation (NAT) provides 1:1 IP. address mapping helping to reduce commissioning time Power over ethernet (PoE) versions provide power to devices over ethernet minimizing cabling Security features, including access control lists, help ensure that only authorized devices, users and traffic can access the network The wide deployment of ethernet /IP in industrial Automation means that there is a growing demand to manage the network properly. Secure Digital (SD) card provides Integtrating new machine-level networks into an existing plant network simplified device replacement requires convergence.

Stratix 5700 Industrial Managed Ethernet Switch The wide deployment of EtherNet/IP™ in industrial automation means that there is a growing demand to manage the network properly.

Tags:

  Stratix, Automation, 7500, Rockwell automation, Rockwell, Ethernet, Stratix 5700

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Stratix 5700 - Rockwell Automation

1 Stratix 5700. Industrial Managed ethernet Switch Features and Benefits: Advanced Networking Features Integrated Device Level Ring (DLR). connectivity helps optimize the network architecture and provide consolidated network diagnostics Integrated Network Address Translation (NAT) provides 1:1 IP. address mapping helping to reduce commissioning time Power over ethernet (PoE) versions provide power to devices over ethernet minimizing cabling Security features, including access control lists, help ensure that only authorized devices, users and traffic can access the network The wide deployment of ethernet /IP in industrial Automation means that there is a growing demand to manage the network properly. Secure Digital (SD) card provides Integtrating new machine-level networks into an existing plant network simplified device replacement requires convergence.

2 Optimized integration: With more devices connected on the same ethernet network than ever before, an industrial managed switch can help you simplify your network Studio 5000 Add-on Profiles (AOPs). enable premier integration into the infrastructure. Adding a managed switch to your network architecture Rockwell Automation Integrated can also help make the process of adding new machines easier. Architecture system The Allen-Bradley Stratix 5700 is a compact, scalable Layer 2 managed Predefined Logix tags for monitoring switch with embedded Cisco technology for use in applications with and port control small isolated, to complex networks. With integration into Studio 5000 Automation Engineering and Design Environment , you can FactoryTalk View faceplates enable status monitoring and alarming leverage FactoryTalk View faceplates and Add-on Profiles for simplified configuration and monitoring.

3 Built-in Cisco Internet Operating System (IOS) helps provide secure By choosing a switch co-developed by Rockwell Automation and Cisco, integration with enterprise network your Operations Technology (OT) and Information Technology (IT). professionals leverage tools and technology that are familiar to them. This collaboration can also help to reduce configuration time and cost. Designed and Developed for ethernet /IP Automation Applications Network Address Translation Machine integration onto a plant network architecture can be difficult as machine builder IP-address assignments rarely match the addresses of the end-user network. Also, network IP addresses are often unknown until the machine is being installed. The Stratix 5700 with Network Address Translation (NAT) is a Layer 2 implementation that provides wire speed 1:1. translations ideal for Automation applications where performance is critical.

4 NAT allows for: Industrial Zone Simplified integration of IP-address 1:1 NAT Mapping 1:1 NAT Mapping mapping from a set of local, Private Public Private Public machine-level IP addresses to the end user's broader plant network Public Network Public Network OEMs to deliver standard machines to end users without programming unique IP addresses 0 1 2 3 4 5 6 7 A0 B0 Z0 0 1 2 3 4 5 6 7 A0 B0 Z0. SOURCE. SOURCE. HIGH SPEED. IN. IN. 24 VDC. 24 VDC. HIGH SPEED. SINK\. INPUT. SINK\. INPUT. DC. DC. COUNTER. COUNTER. 8 9 10 11 12 13 14 15 A1 B1 Z1 8 9 10 11 12 13 14 15 A1 B1 Z1. OUT. OUT. SOURCE. OUTPUT. SOURCE. OUTPUT. 24 VDC. 0 2 FUSE. 24 VDC. 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 2 FUSE. DC. DC. 8 9 10 11 12 13 14 15 1 3 OK 8 9 10 11 12 13 14 15 1 3 OK. Stratix 5700 Stratix 5700. 00 08 A0+ Ao- 00 08 A0+ Ao- 01 09 B0+ B0- 01 09 B0+ B0- 02 10 Z0+ Z0- 02 10 Z0+ Z0- 03 11 A1+ A1- 03 11 A1+ A1- 04 12 B1+ B1- 04 12 B1+ B1- 05 13 Z1+ Z1- 05 13 Z1+ Z1- with NAT.

5 06 14 +V -V 06 14 +V -V. with NAT. 07 15 OUT OUT 07 15 OUT OUT. 0 2 0 2. COM COM OUT OUT COM COM OUT OUT. 0 1 1 3 0 1 1 3. End users to more simply integrate NC NC COM COM NC NC COM COM. V V V V. +V +V OUT OUT. 0+ 0+ +V +V OUT OUT. 0+ 0+. V V V V. 00 08 OUT OUT. 0+ 0+ 00 08 OUT OUT. 0+ 0+. V V V V. OUT OUT OUT OUT. 01 09 0+ 0+ 01 09 0+ 0+. V V V V. 02 10 OUT OUT. 0+ 0+ 02 10 OUT OUT. 0+ 0+. V V. 03 11 COM OUT. 0+ 03 11 COM OUT. 0+. DANGER V DANGER V. 04 12 COM OUT. 0+ 04 12 COM OUT. 0+. 00:00:BC:66:0F:C7 V V 00:00:BC:66:0F:C7 V V. 05 13 OUT OUT. 0+ 0+ 05 13 OUT OUT. 0+ 0+. V V V V. 06 14 OUT OUT. 0+ 0+ 06 14 OUT OUT. 0+ 0+. I I I I. 07 15 OUT OUT. 0+ 0+ 07 15 OUT OUT. 0+ 0+. the machines into the larger network COM COM COM COM COM COM COM COM. 0 1 0 1. Mod Mod Mod Mod Mod Mod Mod Mod Net Net Net Net Net Net Net Net 5500S2 5500S2 5500S2 5500S2 5500S2 5500S2 5500S2 5500S2.

6 2 2 2 2 2 2 2 2. 1 1 1 1 1 1 1 1. IN1 U IN1 U IN1 U IN1 U IN1 U IN1 U IN1 U IN1 U. COM COM COM COM COM COM COM COM. IN2 V IN2 V IN2 V IN2 V IN2 V IN2 V IN2 V IN2 V. SHLD SHLD SHLD SHLD SHLD SHLD SHLD SHLD. W W W W W W W W. D+ D+ D+ D+ D+ D+ D+ D+. D- - D- - D- - D- - D- - D- - D- - D- - + + + + + + + +. MBRK MBRK MBRK MBRK MBRK MBRK MBRK MBRK. MACHINE 1 MACHINE 2. Private Network Private Network Device Level Ring Technology (REP OR STP OR FLEXLINK). Network The Device Level Ring (DLR). protocol is used for high-speed, Stratix 5700 Backup Stratix 5700 Active Supervisor/Gateway Supervisor/Gateway high-performance applications where resiliency is required. DLR is a layer DLR DHCP. 2 protocol that allows multi-port Com Com Configuration Table IN2 IN2. Ref Ref IN1 IN1. ethernet /IP devices to form a ring PORT 8 PORT 7 Index IP Address topology.

7 When the supervisor in 2 the ring detects a break in the ring, 3 it provides an alternate data route to FWD. Enet LINK. FAULT. HERTZ. 5 Esc Sel help recover the network quickly. PORT. Point I/O. MOD. The Stratix 5700 includes integrated NET A. 525 NET B. Powerflex DLR connectivity, which allows the switch to act as a node or a supervisor on the ring. When acting I/O I/O. Mod Mod Mod Mod AC/DC OUT. CHO CHO. DCHO DCHO. Net Net Net Net OK OK 115 VAC RELAY. 5500S2 5500S2 5500S2 5500S2. as a supervisor, the Stratix 5700. 2 2 2 2. 1 1 1 1. IN1 U IN1 U IN1 U IN1 U. COM COM COM COM. IN2 V IN2 V IN2 V IN2 V. SHLD SHLD SHLD SHLD. W W W W. can consolidate information from D+ D+ D+ D+. CompactLogix D- - D- - D- - D- - + + + +. MBRK MBRK MBRK MBRK. Static IP Address the ring, and be the single place Kinetix to manage machine-level network diagnostics and DLR status.

8 With redundant gateway capabilities, the Stratix 5700 can support two switches on a single ring while being directly connected to the rest of the network helping to provide increased resiliency. The switch also offers DHCP IP address assignment to end devices on the DLR network for simplified device replacement. Switch Reference Chart Allen-Bradley Stratix 5700 Industrial ethernet Switch Switch Selection Table CIP Sync CATALOG TOTAL COPPER COMBO SFP PoE SW CONFORMAL. (IEEE NAT DLR. NUMBER PORTS PORTS PORTS SLOTS PORTS TYPE COATING. 1588). 1783-BMS4S2 SGL 6 4 FE +2GE Lite 1783-BMS4S2 SGA 6 4 FE +2GE Full 1783-BMS06SL 6 4 FE 2 FE Lite 1783-BMS06SA 6 4 FE 2 FE Full 1783-BMS06TL 6 6 FE Lite 1783-BMS06TA 6 6 FE Full 1783-BMS06 SGL 6 4 FE 2 GE Lite 1783-BMS06 SGA 6 4 FE 2 GE Full 1783-BMS06 TGL 6 4 FE + 2 GE Lite 1783-BMS06 TGA 6 4 FE + 2 GE Full 1783-BMS10CL 10 8 FE 2 FE Lite 1783-BMS10CA 10 8 FE 2 FE Full 1783-BMS10 CGL 10 8 FE 2 GE Lite 1783-BMS10 CGA 10 8 FE 2 GE Full 1783-BMS10 CGP 10 8 FE 2 GE Full.

9 1783-BMS10 CGN 10 8 FE 2 GE Full . 1783-BMS12T4E2 CGL 18 12 FE 2 GE 4 FE Lite . 1783-BMS12T4E2 CGP 18 12 FE 2 GE 4 FE Full . 1783-BMS12T4E2 CGNK 18 12 FE 2 GE 4 FE Full . 1783-BMS20CL 20 16 FE 2 FE 2 FE Lite . 1783-BMS20CA 20 16 FE 2 FE 2 FE Full . 1783-BMS20 CGL 20 16 FE 2 GE 2 FE Lite . 1783-BMS20 CGP 20 16 FE 2 GE 2 FE Full . 1783-BMS20 CGN 20 16 FE 2 GE 2 FE Full . 1783-BMS20 CGPK 20 16 FE 2 GE 2 FE Full . FE - Fast ethernet GE - Gigabit ethernet Glossary of Terms Key Software Features MAC ID Port Security checks the MAC ID of devices connected to the switch to determine if it is authorized. If not the device is blocked and the Access Control Lists allow you to filter network controller receives a warning message. traffic. This can be used to selectively block This provides a method to block unauthorized types of traffic to provide traffic flow control FEATURE HIGHLIGHTS LITE FULL access to the network.

10 Or provide a basic level of security for accessing your network. Network Address Translation (NAT). Switching provides 1:1 translations of IP addresses from CIP port control and fault detection one subnet to another. Can be used to integrate allows for port access based on Logix controller CIP Sync (IEEE 1588) Separate Option machines into an existing network architecture. program or controller mode (idle/fault). Allows secure access to the network based REP (Resilient Ring Protocol) Port Thresholds on machine conditions. FlexLinks (Storm control & Traffic Shaping). allows you to set both incoming and outgoing CIP SYNC (IEEE1588) is the ODVA QoS traffic limits. If a threshold is exceeded alarms can implementation of the IEEE 1588 precision time be set in the Logix controller to alert an operator. protocol. This protocol allows very high precision STP/RSTP/MST (instances) 64 128.