Stratix Ethernet Device Specifications Technical Data

Technical DataStratix Ethernet Device SpecificationsStratix 2000 Switches (1783-US), Stratix 2500 Switches (1783-LMS), Stratix 6000 Switches (1783-EMS) Stratix 5400 Switches (1783-HMS), Stratix 5410 Switches (1783-IMS), Stratix 5700 Switches (1783-BMS)ArmorStratix 5700 Switches (1783-ZMS), Stratix 8000 and 8300 Switches (1783-MS, 1783-RMS, 1783-MX) Stratix 5100 Wireless Access Point/Workgroup Bridge (1783-WAP), Stratix 5900 Services Router (1783-SR) Stratix 5950 Security Appliance (1783-SAD), Embedded Switch Technology (1783-ETAP), Configurable NAT Router (1783-NATR)TopicPageSummary of Changes2 Additional Resources2 Stratix 2000 Ethernet Unmanaged Switches series B3 Stratix 2000 Ethernet Unmanaged Switches series A10 Stratix 2500 Ethernet Lightly Managed Switches17 Stratix 5400 Ethernet Managed Switches21 Stratix 5410 Ethernet Managed Switches25 Stratix 5700 Ethernet Managed Switches31 ArmorStratix 5700 Ethernet Managed Switches41 Stratix 6000 Ethernet Managed Switches46 Stratix 8000 and Stratix 8

Rockwell Automation Publication 1783-TD001T-EN-P - July 2018 3 Stratix Ethernet Device Specifications Stratix 2000 Ethernet Unmanaged Switches—Series B

Tags:

  Series, Automation, Rockwell automation, Rockwell

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Stratix Ethernet Device Specifications Technical Data

1 Technical DataStratix Ethernet Device SpecificationsStratix 2000 Switches (1783-US), Stratix 2500 Switches (1783-LMS), Stratix 6000 Switches (1783-EMS) Stratix 5400 Switches (1783-HMS), Stratix 5410 Switches (1783-IMS), Stratix 5700 Switches (1783-BMS)ArmorStratix 5700 Switches (1783-ZMS), Stratix 8000 and 8300 Switches (1783-MS, 1783-RMS, 1783-MX) Stratix 5100 Wireless Access Point/Workgroup Bridge (1783-WAP), Stratix 5900 Services Router (1783-SR) Stratix 5950 Security Appliance (1783-SAD), Embedded Switch Technology (1783-ETAP), Configurable NAT Router (1783-NATR)TopicPageSummary of Changes2 Additional Resources2 Stratix 2000 Ethernet Unmanaged Switches series B3 Stratix 2000 Ethernet Unmanaged Switches series A10 Stratix 2500 Ethernet Lightly Managed Switches17 Stratix 5400 Ethernet Managed Switches21 Stratix 5410 Ethernet Managed Switches25 Stratix 5700 Ethernet Managed Switches31 ArmorStratix 5700 Ethernet Managed Switches41 Stratix 6000 Ethernet Managed Switches46 Stratix 8000 and Stratix 8300 Ethernet Managed Switches49 Stratix 5100 Wireless Access Point/Workgroup Bridge56 Stratix 5900 Services Router58 Stratix 5950 Security Appliance60 Embedded Switch Technology63 Configurable NAT Router66 Accessories692 rockwell

2 automation Publication 1783-TD001S-EN-P - May 2018 Stratix Ethernet Device SpecificationsSummary of ChangesThis publication contains new and updated information as indicated in the following ResourcesThese documents contain additional information concerning related products from rockwell can view or download publications at To order paper copies of Technical documentation, contact your local Allen-Bradley distributor or rockwell automation sales 2500 switches power consumption and power dissipation17 Stratix 5400 switches power dissipation21 Stratix 5410 switches power dissipation25 Stratix 5700 switches power dissipation32 Stratix 5700 PoE switches power dissipation35 ArmorStratix switches power dissipation41 Stratix 8000 and 8300 switches power dissipation49 Stratix 8000 and 8300 expansion modules power consumption and power dissipation52 Stratix 8000 and 8300 PoE expansion modules power dissipation53 Stratix 5100 wireless access point power dissipation56 Stratix 5900 services router power dissipation58 Stratix 5950 security

3 Appliance power consumption and power dissipation60 SFP module interface connector types69 ResourceDescriptionConfigurable NAT Router User Manual, publication 1783-UM008 Describes how to install, configure, and troubleshoot the NAT Industrial Protocol White Paper, publication ENET-WP001 Describes how to implement services and data objects on a TCP/UDP/IP based Ethernet Managed Switches User Manual, publication 1783-UM007 Describes how to configure and troubleshoot Stratix 5400, 5410, 5700, 8000, 8300, and ArmorStratix 5700 2000 Ethernet Unmanaged Switches Installation Instructions, publication 1783-IN003 Describes how to install Stratix 2000 2000 Ethernet Unmanaged Switches User Manual, publication 1783-UM011 Describes how to use DIP switches and status indicators on Stratix 2000 2500 Lightly Managed Switches Installation Instructions, 1783-IN011 Describes how to install Stratix 2500 2500 Lightly Managed Switches User Manual, 1783-UM009 Describes how to configure and troubleshoot Stratix 2500 6000 Ethernet Managed Switch User Manual, publication 1783-UM001 Describes how to configure and troubleshoot Stratix 6000 5100 Wireless Access Point/Workgroup Bridge User Manual, publication 1783-UM006 Describes how to install, configure.

4 And troubleshoot the wireless access 5900 Services Router User Manual, publication 1783-UM005 Describes how to install, configure, and troubleshoot the 5950 Security Appliance User Manual, publication 1783-UM010 Describes how to install, configure, and troubleshoot the security automation Wiring and Grounding Guidelines, publication general guidelines for installing a rockwell automation industrial Certifications website, declarations of conformity, certificates, and other certification automation Publication 1783-TD001S-EN-P - May 20183 Stratix Ethernet Device SpecificationsStratix 2000 Ethernet Unmanaged Switches series BCat. No. Total PortsRJ45 Ports(1)(1)FE = Fast Ethernet .

5 GE = Gigabit Ports(1)1783-US5T/B55 FE 1783-US5TG/B55 GE 1783-US4T1F/B54 FE1 FE multimode preinstalled fiber SFP module1783-US4T1H/B54 FE1 FE singlemode preinstalled fiber SFP module1783-US8T/B88 FE 1783-US6T2F/B86 FE2 FE multimode preinstalled fiber SFP modules1783-US6T2H/B86 FE2 FE singlemode preinstalled fiber SFP modules1783-US7T1F/B87 FE1 FE multimode preinstalled fiber SFP module1783-US7T1H/B87 FE1 FE singlemode preinstalled fiber SFP module1783-US6T2TG2F/B106 FE + 2 GE2 FE multimode preinstalled fiber SFP modules1783-US6T2TG2H/B106 FE + 2 GE2 FE singlemode preinstalled fiber SFP modules1783-US8TG2GX/B108 GE2 GE slots(2)(2)SFP modules must be ordered FE 1783-US16T2S/B1816 FE2 FE slots(2)Table 1 - Technical Specifications - Stratix 2000 Switches, series B Attribute1783-US5T/B1783-US5TG/B1783-US4 T1F/B, 1783-US4T1H/B1783-US8T/B1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B1783-US6T2TG2F/B, 1783-US6T2TG2H/B1783-US8TG2GX/B1783-US16 T/B1783-US16T2S/BInrush current, APower input24V ( DC, AC, 50/60 Hz)

6 , SELVP ower consumption, W10 WCurrent, nomDC 180 mAAC 360 mADC 250 mAAC 500 mADC 180 mAAC 360 mADC 250 mAAC 500 mADC 250 mAAC 500 mADC 450 mAAC 900 mADC 550 mAAC 1100 mADC 430 mAAC 860 mADC 430 mAAC 860 mACurrent, maxDC 380 mAAC 750 mADC 510 mAAC 1020 mADC 380 mAAC 750 mADC 510 mAAC 1100 mADC 510 mAAC 1100 mADC 850 mAAC 1700 mADC 1100 mAAC 2200 mADC 900 mAAC 1800 mADC 900 mAAC 1800 mAWire size, ground mm2 (14 AWG) copper wire suitable for 86 C (187 F) above surrounding ambient temperature outside the enclosure, with a suitable ring terminalWire size, DC power mm2 ( AWG) twisted-pair copper wire suitable for 86 C (187 F) above surrounding ambient temperature outside the enclosureScrew torque, ground terminal, N m ( in lb)Screw torque, power N m ( in lb)Enclosure type ratingNone (open-style)4 rockwell automation Publication 1783-TD001S-EN-P - May 2018 Stratix Ethernet Device SpecificationsNorth American temp codeT4T4AT5T4T4T4T4T5 ATEX temp codeT4T4T4T4T4T4T4T4 IECEx temp codeT4T4T4T4T4T4T4T4 MAC addresses, max supported2 K8 K2 K 2 k2 K8 K8 K8 KSFP modules(1)No SFP slotsNo SFP slotsPreinstalledNo SFP slotsPreinstalledPreinstalledOrdered separately.

7 1783-SFP100FX1783-SFP100LX1783-SFP100 EXC1783-SFP100 ZXC1783-SFP1 GSX1783-SFP1 GLX1783-SFP1 GEXE1783-SFP1 GZXNo SFP slotsOrdered separately:1783-SFP100FX1783-SFP100LX178 3-SFP100 EXC1783-SFP100 ZXC(1)For Specifications of preinstalled SFP modules, see Table 2. For Specifications of SFP modules ordered separately, see Table 2 - Preinstalled SFP Module Specifications - Stratix 2000 SwitchesAttributeMultimode (100 Base-FX)Singlemode (100 Base-LX)Central wavelength (nm)13101310 Transmission distance (km)220 Applicable distance (km) power, min (db)-19-10 Luminous power, max (db)-10-5 Receiving sensitivity (dBm)-31-34 Overload luminous power-3-3 Table 3 - Environmental Specifications - Stratix 2000 Switches, series B Attribute1783-US5T/B, 1783-US8T/B1783-US5TG/B, 1783-US4T1F/B, 1783-US4T1H/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B, 1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B, 1783-US16T/B, 1783-US16T2S/BTemperature, operatingIEC 60068-2-1 (Test Ad, Operating Cold),IEC 60068-2-2 (Test Bd, Operating Dry Heat),IEC 60068-2-14 (Test Nb, Operating Thermal Shock)-10 C < Ta < +60 C (14 F < Ta < +140 F)-40 C < Ta < +75 C (-40 F < Ta < +167 F)Temperature, ambient, max60 C (140 F)75 C (167 F)Temperature, surrounding air, max60 C (140 F)

8 75 C (167 F)Temperature, nonoperatingIEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold)IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat)IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) +85 C ( +185 F)Relative humidityIEC 60068-2-30 (Test Db, Unpackaged Damp Heat) noncondensingVibrationIEC 60068-2-6 (Test Fc, Operating)2 g @ HzShock, operatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)15 gShock, nonoperatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)30 gTable 1 - Technical Specifications - Stratix 2000 Switches, series B (continued)Attribute1783-US5T/B1783-US5T G/B1783-US4T1F/B, 1783-US4T1H/B1783-US8T/B1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B1783-US6T2TG2F/B, 1783-US6T2TG2H/B1783-US8TG2GX/B1783-US16 T/B1783-US16T2S/BRockwell automation Publication 1783-TD001S-EN-P - May 20185 Stratix Ethernet Device SpecificationsEmissionsCISPR11 (IEC 61000-6-4)

9 IEC 61000-6-4 ESD immunityIEC 61000-4-26 kV contact discharges8 kV air dischargesRadiated RF immunityIEC 61000-4-310V/m with 1 kHz sine-wave 80% AM from MHz20V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz3V/m with 1 kHz sine-wave 80% AM from MHzEFT/B immunityIEC 61000-4-4 4 kV at 5 kHz on power ports 2 kV at 5 kHz on communication portsSurge transient immunityIEC 61000-4-5 2 kV line-line (DM) and 4 kV line-earth (CM) on power ports 2 kV line-earth (CM) on communication portsConducted RF immunityIEC 61000-4-610V rms with 1 kHz sine-wave 80% AM from 150 MHzEnvironmental ratingIP30 Table 4 - Certifications - Stratix 2000 Switches, series BCertifications (when product is marked)(1)(1)See the Product Certification link at for Declarations of Conformity, Certificates, and other certification , 1783-US5TG/B1783-US4T1F/B, 1783-US4T1H/B, 1783-US8T/B, 1783-US6T2F/B, 1783-US6T2H/B, 1783-US7T1F/B, 1783-US7T1H/B, 1783-US6T2TG2F/B, 1783-US6T2TG2H/B, 1783-US8TG2GX/B, 1783-US16T/B, 1783-US16T2S/Bc-UL-usUL Listed Industrial Control Equipment, certified for US and Canada.

10 See UL File Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for and Canada. See UL File Union 2014/30/EU EMC Directive, compliant with:EN 61326-1; , Industrial RequirementsEN 61000-6-2; Industrial ImmunityEN 61000-6-4; Industrial EmissionsEN 61131-2; Programmable Controllers (Clause 8, Zone A & B)European U