Example: bachelor of science

Straumann Dental implant SyStem

Straumann Dentalimplant SyStemONE SyStem ONE INSTRUMENT KIT ALL INDICATIONS* FOR all inDicationS*!The Straumann Dental implant SyStem offers you and your patients efficient and esthetic implant -borne restorations for a wide range of indi-cations, giving you the flexibility you need in your treatment. Single tooth missing Partially edentulousFully edentulous* From single teeth to edentulous solutions2 Simplicity anD eFFiciency: SOFT TISSUE LEVEL SOLUTIONSS traumann Soft Tissue Level is one of the most widely used soft tissue implant lines. With 10-year long-term results for SLA 1, it is the ideal partner in your practice and the right choice for your patient SigneD to Save time anD increaSe eFFiciency in your Practice2 Soft Tissue Level implant aims at reducing chair time and minimizing treatment complexity Designed to provide integrated soft tissue management through built-in machined collar design High treatment success and patient satisf

Straumann® Dental implant SyStem ONE SYSTEM – ONE INSTRUMENT KIT – ALL INDICATIONS*

Tags:

  System, Instruments, Dental, Implants, Straumann dental implant system, Straumann, 174 dental implant system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Straumann Dental implant SyStem

1 Straumann Dentalimplant SyStemONE SyStem ONE INSTRUMENT KIT ALL INDICATIONS* FOR all inDicationS*!The Straumann Dental implant SyStem offers you and your patients efficient and esthetic implant -borne restorations for a wide range of indi-cations, giving you the flexibility you need in your treatment. Single tooth missing Partially edentulousFully edentulous* From single teeth to edentulous solutions2 Simplicity anD eFFiciency: SOFT TISSUE LEVEL SOLUTIONSS traumann Soft Tissue Level is one of the most widely used soft tissue implant lines. With 10-year long-term results for SLA 1, it is the ideal partner in your practice and the right choice for your patient SigneD to Save time anD increaSe eFFiciency in your Practice2 Soft Tissue Level implant aims at reducing chair time and minimizing treatment complexity Designed to provide integrated soft tissue management through built-in machined collar design High treatment success and patient satisfaction supported by strong scientific evidence3 Placement of an implantHealing capPlacement of a provisional abutment treatment workFlow on SoFt tiSS ue level implant SolutionS3take aDvantage oF tHe eaSy acceSS ibility to tHe implant by working at SoFt tiSS ue level Lean

2 Prosthetic portfolio supported by the implant design Abutment-level impression makes workflow efficient and number of patient visits can be minimized4 Simple impression taking and abutment placement due to the connection at soft tissue level reDucinG TREATMENT compleXityconventional impression taking insertion of the abutmentcrown in place4 The Straumann Bone Level implant line provides you with additional flexibility to deliver an optimal esthetic solution to patients. Bone Level implants complement the Straumann Soft Tissue Level port-folio to offer you wide treatment flexibility and man-ifold anD Fle XiBilty: BONE LEVEL implant SOLUTIONS excellent eStHeticS D ue to bone Pre Servation5,6 anD Smart SoFt tiSSue management Stable crestal bone supporting esthetic outcome5.

3 6 Exclusive self-guiding CrossFit connection designed for a precise fit and stability A wide range of treatment options with the convenience of a confident solution at bone levelthe precise and self-guiding crossFit connectionbone level imPlant5 DeSigneD F or outStanDing eStHetic reSultS anD Flexibility in reStorative ProceDureS Broad range of materials and restorative options designed for an optimal result in every treatment step Natural appearance through full ceramic restorations with customized or standard abutments Smart soft tissue management from start to finish with Consistent Emergence Profiles FOR A WiDe ranGe oF treatment optionS Healing abutmenttemporary restorationFinal restorationconSiStent emergence ProFileS Consistently matching geometries throughout the entire work flow Eases the fabrication of temporary and final restorations Excellent esthetic results5,66 For years, implants with the SLA surface have de-livered excellent results and high implant success , 8 Straumann followed this state-of-the-art development in implant dentistry with the SLActive surface, the next generation in surface technology.

4 Promoting faster osseointegration and providing higher predictability, SLActive has become a cen-tral feature of the implant LEADING SurFace innoVation: SLActive more conFiDence t HrougH Hig Her PreDictability9,10,11 SLActive designed to deliver: Higher security and faster osseointegration for every indication9,10,12 17 Reduced healing times from 6 8 weeks down to 3 4 weeks11 Increased treatment predictability in critical protocols97 Roxolid , the new DNA of implant materials, is a titanium-zirconium alloy, specifically developed for Dental implantology. Roxolid is designed to widen your treatment options with small diameter implants .

5 Mechanical tests have demonstrated higher tensile and fatigue strength of Roxolid implants compared to titanium grade 4 ,19 In combination with the SLActive surface, Roxolid brings high strength and excellent osseointegration properties to the Straumann Dental implant SyStem portfolio. roxoliD t He new Dna o F implant materialS Confidence when placing small diameter implants Flexibility of having more treatment options Designed to increase patients acceptance of implant treatmentDRIVING material innoVation: ROXOLID 8 Simplicity: ONE SYSTEMThe proven Straumann Dental implant SyStem (SDIS) is a broad portfolio of Soft Tissue and Bone Level implants that allows you to deliver an optimal treat-ment to your patients.

6 implant PortFoliothe classic implant for one-stage surgerythe implant for flexible healing protocolsthe implant for immediate placement and superior pri- mary stabilitythe implant for confidence and esthetics at bone levelmost common clinical situations Straumann StandardStraumann Standard PlusStraumann Tapered EffectStraumann Bone LevelAnterior region Posterior region Small interdental space (NN) Thin mucosa biotype Thick mucosa biotype Bone augmentation with simultaneous implant placement Submerged healing Non-submerged healing Immediate implant placement in extraction socket Internal sinus lift Highly recommended RecommendedPlease note that the size limitations according to the instructions for use of each Straumann product apply and must be observed.

7 Each Straumann product must be used in accordance with the instructions for use provided by Straumann . It is the practitioner s responsibility to use the device in accordance with these instructions for use and to determine if the device fits the individual patient situation. 9 Straumann Surgical cassetteStraumann g uided Surgery cassetteSimplicity: ONE INSTRUMENT KITFor your convenience, the appropriate Straumann surgical instrument kit can be used for all implant lines of the Straumann Dental implant SyStem , in both conventional and guided surgery. Straumann i nStrument kit For eaSe oF HanDling The easy-to-read user guide ensures a reliable working sequence through color-coded arrows and silicone sleeves The cassette can be packed to reflect the working procedure (which is performed either using the handpiece or manually with the ratchet) Clear illustrations and drill length stops confirm, at a glance, that the arrangement of instruments , screws and healing caps is complete and correctPROSTHETIC OPTIONS COVERING A Variety oF inDicationSChoose between different materials and follow your preferred workflow!

8 The Straumann prosthet-ics portfolio offers you the esthetics and flexibility you need in your practice. cHooSe tHe accurate ProStHetic o Ption Solid abutments are designed to facilitate the restoration of implants Flexible and comprehensive synOcta portfolio offers the perfect restorative solution Easy to achieve esthetics with anatomic abutmentstitaniumgoldceramicscobalt-chro me Cementable Solid synOcta CementablesynOcta Angled Anatomic CADCAM synOcta Multi-Base Straumann CARES Screw-retained bridge synOcta Gold Gold Anatomic IPS Abutment CADCAM Straumann CARES Screw-retained bridge Single toothScrew-retained Cemented Partially edentulousScrew-retained Cemented basic Solutionsadvanced SolutionsPremium

9 Solutions LOCATOR Bar Retentive anchor Individualized bar Telescopic constructions synOcta Multi-Base Gold Straumann CARES Screw-retained Dolder Bar Straumann CARES Screw-retained bridge Fully edentulousRemovable overdentures Fixed overdentures ProStHeticS P ortFolio Soft Tissue Level implants Bone Level implants Natural-looking esthetics with CADCAM abutments Flexible and comprehensive Multi-Base portfolio designed for perfectly fitting screw-retained multiple unit restorations Due to their standard designs, LOCATOR and bar components are ready to use in a variety of indicationstitaniumgoldceramicscobalt-ch rome Cementable Solid synOcta CementablesynOcta Angled Anatomic CADCAM synOcta Multi-Base Straumann CARES Screw-retained bridge synOcta Gold Gold Anatomic IPS Abutment CADCAM Straumann CARES Screw-retained bridge Single toothScrew-retained Cemented Partially edentulousScrew-retained Cemented basic Solutionsadvanced SolutionsPremium Solutions LOCATOR Bar Retentive anchor Individualized bar Telescopic constructions synOcta Multi-Base Gold Straumann CARES Screw-retained Dolder Bar

10 Straumann CARES Screw-retained bridge Fully edentulousRemovable overdentures Fixed overdentures 125 Bone Control Design is an implant design which has been applied consistently to the Straumann Dental implant SyStem . It is built on 5 key factors for bone preservation and thus provides a crucial foun-dation for esthetic results and long-term : BONE CONTROL DESIGN The Straumann Dental implant SyStem is your reli-able partner in implant treatment, giving you simple and convenient solutions for your success!1. Respecting the biological distanceoPtimize creStal bone Pre Servation2. Optimal position of smooth and rough surface interface3.


Related search queries