Example: biology

Strongwell Specifications - Welcome to Acadian ...

Strongwell SpecificationsSection 06600 Fiberglass Reinforced Plastic Products and FabricationsSECTION 06600 FIBERGLASS REINFORCED PLASTIC PRODUCTS AND FABRICATIONSPART 1 - and general provisions of Contract, including General and SupplementaryConditions and Division-1 specification Sections, apply to work of this section includes the following FRP Products & Stairs and Gratings and Structural Ladders & Foam Cored Building OF all labor, materials, equipment and incidentals necessary to install thefiberglass reinforced plastic (FRP) products as specified material covered by these Specifications shall be furnished by a reputable andqualified manufacturer of proven ability who has regularly engaged in themanufacture and installation of FRP of any component or modification of system shall be made only whenapproved by the Architect or Qualific

Strongwell Specifications Section 06600 Fiberglass Reinforced Plastic Products and Fabrications

Tags:

  Specification, Strongwell specifications, Strongwell

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Strongwell Specifications - Welcome to Acadian ...

1 Strongwell SpecificationsSection 06600 Fiberglass Reinforced Plastic Products and FabricationsSECTION 06600 FIBERGLASS REINFORCED PLASTIC PRODUCTS AND FABRICATIONSPART 1 - and general provisions of Contract, including General and SupplementaryConditions and Division-1 specification Sections, apply to work of this section includes the following FRP Products & Stairs and Gratings and Structural Ladders & Foam Cored Building OF all labor, materials, equipment and incidentals necessary to install thefiberglass reinforced plastic (FRP) products as specified material covered by these Specifications shall be furnished by a reputable andqualified manufacturer of proven ability who has regularly engaged in themanufacture and installation of FRP of any component or modification of system shall be made only whenapproved by the Architect or Qualifications.

2 Firm experienced in successfully producing FRPfabrications similar to that indicated for this project, with sufficient productioncapacity to produce required units without causing delay in the addition to requirements of these Specifications , comply with manufacturer sinstructions and recommendations for design of FRP products including connections shall be in accordance with govern-ing building codes and standards as of FRP live loads on grating shall not be less than 100 pounds per sq. ft. Grat-ing deflection at the center of a simple span not to exceed .25 members shall be designed to support all applied loads.

3 Deflection in anydirection shall not be more than L/180 of span for structural members. Connectionsshall be designed to transfer the drawings of all FRP structural members, handrails, gratings, plate, ladders andappurtenances shall be submitted to the Engineer for approval in accordance with therequirements of Section s catalog data , spacings, and construction of tables showing limits for span length and deflection under various uni-form and concentrated of shop drawings and identification and type of supporting frames of each type of product proposed shall be submitted for approval prior toplacement of purchase AND STORAGE systems.

4 Sub-systems and structures shall be shop fabricated and assembled intothe largest practical size suitable for materials and equipment necessary for the fabrication and installation of the grat-ing, plate, handrails, stair treads, structural shapes and building panels shall be storedbefore, during, and after shipment in a manner to prevent cracking, twisting, bending,breaking, chipping or damage of any kind to the materials or equipment, includingdamage due to over exposure to the sun. Any material which, in the opinion of theEngineer, has become damaged as to be unfit for use, shall be promptly removed fromthe site of work, and the Contractor shall receive no compensation for the damagedmaterial or its and match-mark all materials, items, and fabrications for installation and 2 - used in the manufacture of the FRP products shall be new stock of the bestquality and shall be free from all defects and imperfections that might affect the perfor-mance of the finished materials shall be of the kind and quality specified.

5 And where the quality is notspecified, it shall be the best of the respective kinds and suitable for the FRP products noted in shall be manufactured using a pultruded process utiliz-ing either an isophthalic polyester or a vinyl ester resin with flame retardant and ultra-violet (UV) inhibitor additives. A synthetic surface veil shall be the outermost layercovering the exterior surface. The FRP shapes shall achieve a flame spread of 25 orless in accordance with ASTM test method E-84. (Isophthalic polyester resin is avail-able without flame retardant and UV inhibitor additives.)

6 Fabrication, all cut ends, holes and abrasions of FRP shapes shall be sealed witha compatible resin coating to prevent intrusion of products exposed to weather shall contain an ultraviolet inhibitor. Should addi-tional ultraviolet protection be required, a one mil minimum coating can be exposed surfaces shall be smooth and true to approved alternative AND shall be shipped from the manufacturer, palletized and banded withexposed edges protected by cardboard to prevent damage in piece shall be clearly marked showing manufacturer s applicable shall be DURADEK or DURAGRID as manufactured by Strongwell -Chatfield Division, Chatfield.

7 Panels shall be _____ inches deep and sustain a deflection of no more inches under a uniform distributed load of 100 psf for the span lengths shownon the bearing bars shall be joined into panels by passing continuous length fiber-glass pultruded cross rods through the web of each bearing bar. The pultrudedcross rod assembly shall consist of two cross rod spacers that have notches cutinto them at _____ inches on center to fit the distance between the web of eachbearing bar. A continuous fiberglass pultruded bar shaped section shall bewedged between the two cross rod spacers mechanically locking the notches inFebruary 199606600-3the cross rod spacers to the web of the bearing bars.

8 Continuous chemical bond-ing shall be achieved between the cross rod spacers and the bearing web andbetween the bar shaped wedge and the two cross rod spacers locking the entirepanel together to give a panel that resists twist and prevents internal movementof the bearing treads shall be capable of withstanding a uniform load of 100 lbs. per sq. a concentrated load of 300 lbs. on an area of 4 sq. inches located in thecenter of the tread, whichever produces the greater top surface of all panels shall have a non-skid grit affixed to the surface byan epoxy resin followed by a top coat of epoxy shall be fabricated to the sizes shown on the down clamps shall be type 316L stainless steel saddle clips.

9 A minimum of4 each per or -Hold down clamps shall be type 316L stainless steel insert hold downs as pro-vided by Strongwell -Chatfield Division. A minimum of 4 each per shall be high visibility or -Color shall be bearing bars that are to be exposed to UV shall be coated with polyurethanecoating of a minimum thickness of 1 FRP grating and stair treads shall be fabricated from bearing bars and crossrod manufactured by the pultrusion process. The bearing bars shall be ____inch deep with a ____ inch wide top flange, a ____ inch wide bottom flange anda web thickness of ____ inch.

10 The glass fiber reinforcement for the bearing barsshall be a core of continuous glass strand rovings wrapped with continuousstrand glass mat. A synthetic surface veil shall be the outermost layer coveringthe exterior Grating and Stair Treadsa) Fiberglass grating and stair treads shall be made from a premium gradechemical resistant, fire retardant vinyl ester resin system with antimonytrioxide added to meet the flame rating of 25 or less in accordance withASTM E-84 testing and meet the self-extinguishing requirements of ASTMD-635. U. V. inhibitors are added to the ONEPICK ONEOPTIONALF ebruary with SAFPLATE a) Grating shall be the same as described above in this )SAFPLATE shall be EXTREN as manufactured by Strongwell -BristolDivision, Bristol, VAc)SAFPLATE shall be manufactured using a premium grade polyester orvinyl ester resin with fire retardant additive to meet Class 1 flame rating of25 or less as tested by ASTM E-84 and meet the self-extinguishing require-ments of ASTM D-635.