Super Firetemp® T Board - coupe-feu

Fire Protection SystemsGrease & VentilationDuct SystemsSuper firetemp T BoardProduct Manual2 FPS-199- 7-01 (new)Table of ContentsProduct Information 3 Listings 4 Product Properties 5 Board /Wrap Transition 7 Architects Specification 8 Installation Guide10 Materials Estimating Guide17 Suggested Installation Details193 FPS-199- 7-01 (new) Super firetemp T Board from johns manville was made for grease and Ventilation structural grade calcium silicate material tested to 2000 F is the best of all alternativesfor preventing a fire in a kitchen grease or ventilation duct fire from spreading throughout Board provides a 1 and 2 hour fire rated enclosure around any kitchen exhaust hood, ductor ventilation Board is faster, easier and more economical to install than traditional out these features and benefits of T- Board compared to drywall.

3 FPS-199- 7-01 (new) Super Firetemp ® T Board from Johns Manville was made for grease and Ventilation ducts. The structural grade calcium silicate material …

Tags:

  Board, John, Super, Johns manville, Manville, Super firetemp, Firetemp, 174 t board

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Super Firetemp® T Board - coupe-feu

1 Fire Protection SystemsGrease & VentilationDuct SystemsSuper firetemp T BoardProduct Manual2 FPS-199- 7-01 (new)Table of ContentsProduct Information 3 Listings 4 Product Properties 5 Board /Wrap Transition 7 Architects Specification 8 Installation Guide10 Materials Estimating Guide17 Suggested Installation Details193 FPS-199- 7-01 (new) Super firetemp T Board from johns manville was made for grease and Ventilation structural grade calcium silicate material tested to 2000 F is the best of all alternativesfor preventing a fire in a kitchen grease or ventilation duct fire from spreading throughout Board provides a 1 and 2 hour fire rated enclosure around any kitchen exhaust hood, ductor ventilation Board is faster, easier and more economical to install than traditional out these features and benefits of T- Board compared to drywall.

2 Super firetemp T Board [[[[ No steel stud framing air gap vs 4 -6 [ One Layer vs 3-5[[[[ Requires fewer screws[[[[ Butt joints[[[[ No taping[[[[ 1/3 installation time[[[[ One Inspection[[[[ Easily cut to fit[[[[ Zero clearance to combustibles[[[[ Simple clean out doors[[[[ Compliance to UL 1978 Grease duct ISO-6944 ventilation ductDesigned to ProtectGrease and Ventilation ducts4 FPS-199- 7-01 (new)Listings System Testing & ApprovalsGrease DuctUL YYET MH 19893 OPL 16053-1 GD 503 R GD 505 C GD 515 RSBCCI PST & ESI 2134 Air DuctOPL VAD 521 RULC FRD-11 Firestop ApprovalsUL W-L-7055 C-AJ-7060 C-AJ-7061 OPL FS546 W FS547 W FS 551 WUL 1978 Standard for grease ducts internal fire testNormal Temperature test (soaking heat) 500 FAbnormal Temperature test (grease duct fire)]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]] ]]]]]]

3 2000 FASTM E119 External Fire Test2 hour full engulfment testASTM E814 Firestop penetration2 hour engulfment with hose stream testISO-6944- Ventilation duct standard1 or 2 hour full engulfmentNFPA 96 Standard for ventilation control and fire protection ofcommercial cooking operationsField fabrication criteria for zero clearance to combustibleSystem Testing and ListingThe enclosure meets the following requirements:Agency ListingOPL16053-1#07820 Classification - 48" ductsISO-6944 - 1985 for Ventilation DuctsULUL Classification YYET - 24" ductsNFPA 96 Standard for Ventilation Control and FireProtection of Commercial Cooking OperationSBCCIS outhern Building Code Congress International When installed according to the directions stated herein5 FPS-199- 7-01 (new)DescriptionSuper firetemp T Board is an inorganic,incombustible material.

4 Chemically, Super firetemp T Board features a tobermorite crystal structure thatresults in exceptional strength and controlled waterof hydration. Super firetemp T Board is composedprimarily of lime, silica, and reinforcing fibers. Theproduct is white, essentially dust-free, and containsno asbestos. It has been fire tested up to 2000 F(1093 C).ApplicationsUses include 1 & 2 hour fire-rated enclosures aroundkitchen exhaust hoods and ventilation ducts. SuperFiretemp T Board meets the requirements definedby Underwriters Laboratories (UL), the National FireProtection Association (NFPA 96), and SBCCI. It isan alternative method of providing duct fireprotection instead of the traditional shaft wallenclosure construction around a duct. For designflexibility, JM also has the first approved grease ductenclosure that combines Super firetemp T boardwith firetemp Design.

5 Super firetemp T Board is anOmega Point Laboratories and UnderwritersLaboratories (UL) classified Board . The product isnon combustible and complies with 25/50 flame andsmoke requirements per ASTM Installation. Super firetemp T Board islightweight. Cutting and fabrication of the boardaround ducts is easily accomplished, therebyminimizing labor Saving. Super firetemp T Board is a singlelayer system with zero clearance to combustiblewhich makes it ideal for tight Board . The Board is self supporting and doesnot depend on the strength of the duct to supportthe weight of the fire protection The product s sanded surface readilyaccepts oil-based paints, wall coverings and Rated Doors. Super firetemp T Board beingstrong and rigid will allow for the installation oftypical fire rated inspection doors used in shaft wallenclosures (check local codes for applicability andapproval for use).

6 System Testing and ApprovalsASTM C 656, Type II, Grade 5 ASTM C 795: PassesASTM E 84: Flame Spread: 0, Smoke Development:0 ASTM E 136: PassesASTM E 119; UL 263; NFPA 251:1 to 2 hour rating for fire rated enclosureUL 1978: Internal Grease Duct and Air Duct FireTestASTM E 814; UL 1479: Through penetration, 2-hour F and T ratings using firetemp CI & SIfirestopping Laboratories Inc. YYETO mega Point LaboratoriesAvailable FormsSuper firetemp T Board is manufactured in 4' x 8'( m x m) panels with a sanded finish onone or both sides. The standard thickness forSuper firetemp T Board is 2" (51 mm).Technical ServicesFor technical information and assistance regardingapplication information, code approvals andperformance specifications, call 1-800-872-0338.

7 Ifthis piece is more than one year old, please contactJohns manville for the current PlacementRefer to the maps on the back page to find theappropriate location for placing firetemp T BoardDuct Insulation6 FPS-199- 7-01 (new)SpecificationsPhysical PropertiesDensity (Average) .. 18 pcf (288 kg/m3)Maximum Recommended Continuous Service Temperature ..1200 F (649 C)Flexural Strength .. 140 psi (965 kPa) Compressive Strength@ 10% Deformation..400 psi (2,758 kPa)Moisture Content, NormalPercentage of Dry weight.. 4 Standard SizesThickness* .. 2" (51 mm)Sheet Size .. 4' x 8' ( m x m)Dimensional TolerancesLength and Width .. + 1/8" (3 mm)Thickness (sanded one side) .. 1/8" (3 mm) +1/4" (6 mm)* Other thickness' available upon requestLinear Shrinkage After 24 Hours at Temperatures, % WeightTemp F ( C) Length Width Thickness Loss1200 (649) <1% <1% <1-1/2% <9%Thermal Conductivity ( k )Mean Temp k F C Btu in/(hr sqft F)W/m K200 93.

8 54 204 .61 316 .67 427 .73 Calstik AdhesiveColor: whiteAvailable in 1-5 gallon pailsFirestop BarrierFiretemp CI, SI or SEReady to use water based sealant offered as caulk or spray masticColors: CI (Red), SI (Blue), SE (Grey) firetemp Wrap is a high temperature insulation blanket specificallydesigned to provide one and two hour fire ratings around manycommercial firetemp T BoardDuct Insulation7 FPS-199- 7-01 (new)AdvantagesSimplified Installation. This transition provides flexibilityto the installer to utilize the installation benefits of theboard and wrap, while providing an approved greaseduct fire protection system. Use of this transition willallow for time or labor saving by maximizing installationefficiency and by providing flexibility for installation indifficult spaces.

9 Before and after any transition followthe installation recommendations described for the boardand wrap Testing and ApprovalsThis transition using Super firetemp T Board andFiretemp Wrap has been fully tested against internalgrease duct fires (UL 1978), external fires (ASTM E119/UL 263), through penetration, insulated duct fires (ASTME814/ UL 1479), and surface burning (ASTM E84/UL723). Omega Point Laboratories (OPL) fire endurancetesting agency accredited by ICBO, BOCA and SBCCI(National Evaluation Services) in the United Statesperformed these tests and have provided Board and wrap as described in installation guides before or after transition transition, install Board , then butt inner layer of wrap next to Board . Hold first layer of blanket in place by attaching stainless steel band ( thick) 1 from edge of blanket.

10 Coat a 5-inch width of Board , with Super Calstik adhesive, adjacent to butt joint of wrap. Overlap the second layer of wrap a minimum of 5 inches over the Board and incontact with the Super Calstik adhesive. Overlap the blanket a minimum of 3 inches over itself. Attached 2 longcoarse dry wall screws with washers (1 1/2 speed clips) every 8 OC and from 3-4 inches from the edge of each additional stainless steel bands over wrap as described in wrap installation guide. See Figure 1 for visual depictionof Board /wrap firetemp T Board and firetemp WrapTransition - Installation GuideSuper firetemp T Board and WrapTransition - Joint SystemMetal BandsSuper Calstik AdhesiveFiretemp WrapSuper FiretempBoard5" Blanket overlapover Board2 1/2" coarse drywall-screws & 3/4" washersFigure 1 Inner LayerExterior Layer T BoardWrap8 FPS 199 - 7-01 (new)Architects Specification - Super firetemp T BoardJohns manville Super firetemp T Board Commercial Kitchen Grease and Air Ventilation Duct SystemPart 1 - Description of SystemA.