Example: bachelor of science

Sure-Lites TD505021EN SLX Series - Cooper Industries

Sure-Lites D ES C R IPTION. Catalog # Type SLX Series LED exit is a steel unit suitable for commercial, institutional, and multi-housing applications. With the new advanced standard features and industry leading innovations, they are now the most Project universal, energy friendly, easiest to stock and install, and safest Exits in their class. Comments Date Prepared by SPECIFIC A TION FEA TUR E S. E lect r i c a l Hous i ng Cons tructio n Warran ty - General Features - 20-gauge steel housing - Exit 1 year - Field selected red and green sign - Universal pattern knockouts on - Battery: 5-Year pro-rata capability standard on all units rear for direct mounting to (units shipped red, field convert to junction box Lamp Data green with supplied parts) - Knockouts for chevron - AC LED: Red and green LED.

AP SERIES EXITS WITH SQUARE HEADS COMBO Sample Number: SLX7, SLX7SD90, SLX6SR2, SLX7SD23050 Family SLX=Steel Exit, LED Series 6=AC Only 7=Self Powered Housing Finish Blank=White BK=Black S Open Face for Signage (single face, White housing only) = …

Tags:

  User, Series, Industreis, Cooper industries, Cooper, Black, Ielts, Sure lites td505021en slx series, Td505021en

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Sure-Lites TD505021EN SLX Series - Cooper Industries

1 Sure-Lites D ES C R IPTION. Catalog # Type SLX Series LED exit is a steel unit suitable for commercial, institutional, and multi-housing applications. With the new advanced standard features and industry leading innovations, they are now the most Project universal, energy friendly, easiest to stock and install, and safest Exits in their class. Comments Date Prepared by SPECIFIC A TION FEA TUR E S. E lect r i c a l Hous i ng Cons tructio n Warran ty - General Features - 20-gauge steel housing - Exit 1 year - Field selected red and green sign - Universal pattern knockouts on - Battery: 5-Year pro-rata capability standard on all units rear for direct mounting to (units shipped red, field convert to junction box Lamp Data green with supplied parts) - Knockouts for chevron - AC LED: Red and green LED.

2 - Dual Voltage Input 120/277 directional indicators lamps provide uniform diffused VAC,60Hz - Canopy allows ceiling or illumination - AC Only end Mounting - DC: Red and green LED DC. - Optional 2C (Two circuit, FTBR) - Universal styles offer lamps (Brighter in emergency available in 120/277 VAC in complete installation mode). standard and emergency flexibility with canopy, operation backplate, and two stencil - Self Powered faces - Sure-Lites EZ Key patented external battery disconnect Ba tte ry ( Se l f Pow ered On ly). SLX Series . feature - Sealed Nickel Cadmium prevents unnecessary - Maintenance-Free, Long-Life battery drainage, saves on - Full Recharge Time, 24 hrs. (max). installation time STEEL EXIT.

3 - Solid-state Voltage Limited Code Compl i a nc e SURFACE MOUNT. Charger - UL 924 Listed - Brownout Circuit - UL Damp Location (0-40C LED LAMPS. - Low-Voltage Disconnect - Life Safety NFPA 101. EX IT LIGH TING. - Test Switch/Power Indicator Light - NEC/OSHA. - Standard 24 hour recharge time - Most State and Local Codes (max) - NOM Certified - Eagle Eye Self-Diagnostic - UL Listed for 2C (FTBR). Standard ENERGY DATA. Maximum power consumption 6 7/8" [175mm]. under all charge conditions: AC Only, 120V - Red 6 7/8" [175mm] Amps: 4 5/8" Watts: 2 1/4" [57mm]. [117mm] Power Factor: AC Only, 120V - Green Amps: Watts: 1 1/4" [32mm] Power Factor: AC Only, 277V - Red Amps: Watts: Power Factor: AC Only, 277V - Green 7 1/2" [191mm].)

4 Amps: Watts: Power Factor: Self Powered, 120V - Red Amps: Watts: 12 1/4" [311mm] Power Factor: Self Powered, 120V - Green Amps: Watts: Power Factor: Self Powered, 277V - Red Amps: Watts: Power Factor: Self Powered, 277V - Green Amps: Watts: Power Factor: TD505021EN . 2017-1-30. A P Series EXITS WITH SQUARE HEADS COMBO. OR D ER ING INFOR M A TION. Sample Number: SLX7, SLX7SD90, SLX6SR2, SLX7SD23050 [Options for non-EXIT signs]. Family Face Options Features Signage Options (Color) Signage Options (Common Signs). SLX =Steel Exit, LED Blank = Single and Blank = No additional Blank = EXIT sign Blank = EXIT sign Double options R = Red letter, 1 = AREA OF RESCUE . S =Open Face for 2C =Two Circuit Red LED 2 = SALIDA.

5 Signage (single face, Option (SLX6 only) G = Green letter, 3 = STAIRS . Series White housing only) SD =Self Diagnostics Green LED 4 = AREA OF REFUGE . 6 =AC Only B = Blue letter, Standard (SLX7 only) 5 = IN USE . 7 =Self Powered White LED. Housing Finish SD90 =Self Diagnostics 6 = NOT AN EXIT . with Fire 7 = (WHEEL CHAIR SYMBOL). Blank = White Alarm Interface 8 = X-RAY ON . BK = black Capability 9 = LASER IN USE . (SLX7 Only) 10 = DO NOT ENTER . Available Accessories (Order Separately). Notes: Protection Devices Pendant Kit WG10 = Wall mount PK18 PKWH = 18 Pendant Kit, White 1 Consult factory for additional custom signage options. wire guard PK18 PKHTWH = 18 Hang True 2 Blue Letters, White LED does not have the SD option.

6 WGS11 = Ceiling or End Pendant Kit, White 3 Units ordered with Salida signage ( , SLX6SR2) will use a steel stencil mount wire guard PK18 PKBK = 18 Pendant Kit, black VS1 = Polycarbonate PK18 PKHTBK = 18 Hang True that outlines the word Salida , while all other signage options will be open-face. Vandal Shield Pendant Kit, black VS1WP = Polycarbonate Vandal Shield, Weather Proof TECHNIC A L D A TA. Lam p s Brownout Circuit (S elf P owered On ly) performance over a wide range of temperatures, SLX Series Exits use energy efficient, long life The brownout circuit on Sure-Lites ' exits from 0-40 C. The specially designed re-sealable LED's to provide uniform diffuse illumination of monitors the flow of AC current to the exit and vent automatically controls cell pressure, the exit face.

7 These red and green LEDs require activates the emergency lighting system when a assuring safety and reliability. This battery is no maintenance and consume less than one predetermined reduction of AC power occurs. best suited for harsh ambient temperatures watt, on average. This dip in voltage will cause most ballasted because the electrolyte is not active in the fixtures to extinguish causing loss of normal electrochemical process. H o u sin g C o n s t r u c t i o n lighting even though a total power failure has Exit housing is constructed of durable 20-gauge not occurred. 2 C (AC On ly). cold rolled steel with corrosion resistant The 2C Option enables the Exits to operate polyester powder coat paint finish.

8 All exits can Sol i d- State Tran sfer (S elf P o wered per the requirements of UL 924 when connected be mounted and wired through knockouts O nl y ) simultaneously to both normal and emergency located on the top and side. Surface mount back The SLX Series Exit incorporates solid-state power circuits (two circuit operation UL. panel has knockouts for direct mounting to switching which eliminates corroded and pitted Category FTBR Emergency Lighting and Power junction box. The mounting canopy is made of contacts or mechanical failures associated with Equipment). The 2C Option is a factory impact resistant thermoplastic with relays. The switching circuit is designed to assembly change which alters the standard Exit complementary finish.

9 Stencil face exits are detect a loss of AC voltage and automatically such that it complies with and is UL Listed supplied with knockout chevron directional energizes the lamps using DC power. Upon under the FTBR Category. This option should indicators for easy conversion to directional restoration of AC power, the DC power will be only be used for exits which are intended to be exits. Exit stencil and backplate install in disconnected and the charger will automatically connected simultaneously to normal and channels in the exit housing to eliminate light recharge the battery. emergency power circuits. Both circuits have leaks. universal 120/277 VAC standard. L ow Vol tage Discon n ect (S elf P o wered Len s O nl y ) E ag le E ye S elf Diagn o st ics S t an d ar d Lenses for the SLX Series Exits are made from When the battery's terminal voltage falls, the o n S LX7.

10 Durable, impact resistant polycarbonate. All exit low-voltage circuitry disconnects the lighting The self-diagnostic unit will automatically faces are designed with full 3/4 stroke snap-out load. The disconnect remains in effect until perform all tests required by UL924, and NFPA. or snap-in chevron directional indicators to normal utility power is restored, preventing 101. The system indicates the status of the exit insure maximum visibility and compliance with deep battery discharge. at all times using the LED indicator near the test the latest codes. Units come with red lenses switch on the side of the unit. A 90 minute installed and green lenses included for field Te s t Switch/P ower In d icator Lig h t battery power (emergency mode) simulation selectable red or green signs.


Related search queries