Designed and built without compromiseSuperbly styled and designed to meet the current EN54requirements, the NEW Surveyor Envoy combines valuefor money with an advanced specification. Available as aone zone extendible to 4 zones, either with the addition of3 hy-spec single zone cards, or a combined budget 3 zonecard. Acompact, single zone is also available for thesmaller installation. Twin Wire operation can now be selected by simple of the art, surface mount technology and automatictest machinery, ensure that high standards of reliability andperformance are 1-4 ZONEC O N V E N T I O N A LC O N T R O LPA N E L SPRODUCT FEATURESn1 zone extendible to 4 zonesnAvailable as a compact 1 zonenDesigned to EN54 Pt.

Designed and built without compromise Superbly styled and designed to meet the current EN54 requirements, the NEW Surveyor Envoy combines value

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SURVEYOR-ENVOY 1-4 ZONE

1 Designed and built without compromiseSuperbly styled and designed to meet the current EN54requirements, the NEW Surveyor Envoy combines valuefor money with an advanced specification. Available as aone zone extendible to 4 zones, either with the addition of3 hy-spec single zone cards, or a combined budget 3 zonecard. Acompact, single zone is also available for thesmaller installation. Twin Wire operation can now be selected by simple of the art, surface mount technology and automatictest machinery, ensure that high standards of reliability andperformance are 1-4 ZONEC O N V E N T I O N A LC O N T R O LPA N E L SPRODUCT FEATURESn1 zone extendible to 4 zonesnAvailable as a compact 1 zonenDesigned to EN54 Pt.

2 2 & 4nComprehensive specificationnZonal sounders & AuxsnMax 5 sounder outputsnZone/sounder disablementsn4 wire to Twin Wire link selectionnIntegral detector removal monitoringn3 Wire compatible (budget model)nKeypad controls and programing nEngineer s walk testnPrecinct inputs nSurface Mount Technology for increased reliabilitynCE marked for EMC & LVDnHochiki Live line selectionnLockable, metal enclosure for durabilitynSlide-in zone chartnDistinctive stylingAdditional SpecificationInput Supply:230 Volts 50Hz, Fused terminal blockPower Supply:Current limited 1 Amp, suits SLAbatteries only. Charging voltage volts DC :18 swg mild steel, 20mm knockouts, colour reference.

3 BS4800 18B17 Blue mink, textured, powder coatCabinet Size:1 zone 277 W 200 H 97 D mm1 - 4 zone 400 W 200 H 97 D mmEnd of line devices:Detection, sounders & monitored I/Pcircuits: 4K7 Earth continuity:4 way brass terminal blockRepeater panel:FCRP- L04 1-4 zone (as Level)Main Features (common to all panels)1 - 4 zones availableSuits most detectorsZonal sounders4 Wire or Twin Wire Activate controls keyswitchSoft tactile keypad for controls & programingConventionally wired, compatible with most detectorsIntegral detector removal monitoring by zone1 Amp linear power supply, Nom. 24V DCDesigned to EN54 Pt. 2 & 4 Min 2 sounder outputs2 Aux C/O relays (1 x Fire) (1 x Fault), voltage freeZonal & common repeater O/PsPrecinct/class change I/PZonal walk test, with or without soundersSounder walk testIntegral detector removal monitoringHochiki Live line selectionSlide-in zone chartDetector removal walk testDisable zones, sounder O/Ps & Aux O/PsRemote Silence & Reset inputsMonitored Evacuate Input3 wire compatible (budget version only)Alarm load.

4 1 Amp shared between sounder outputsPart Conventional Twin Wire Total Sounder QuiescentPanel CurrentMax Qty Sounder cctsQty Sounder cctsLoad (Amps)Currentin AlarmBatteriesFCPENV 11 Compact, hy-spec22157 mA100 AhFCPENV 1 EXT1 Extendable, hy-spec,22157 mA100 mA7 AhTPC ENV 1Z1 Zone card, hy-spec11-19 mA56 mA-TPC ENV 3Z3 Combined zone card,0--28 mA35 mA-budget specAdditional Features for hy-spec versionsLink selectable:Conventional 4 wire to Twin Wire Twin Wire , suits Hochiki & Apollo (see below)Link selectable:zonal fire non latchzonal short circuit firezonal Twin Wire zonal soundersZonal voltage free c/o relayMax 5 sounder outputs (4 zone)Additional Features for budget versionsAux relay, common, voltage free c/oLink selectable:zonal fire non latchshort cct = fireZenner clamp, Hochiki, Live Line Selection3 Wire circuit operationExternal Indications at level 1 External Controls at level 2 Common Fire, Zonal Fire, Activate Controls keyswitch,Zonal Fault, Common Fault,Silence Alarms, Reset,Zone Disabled, Sounder Disabled,Isolate Remote, Test ModeSounder Fault, Detector Removed,Disabled, Test Leds,Zones/Sounders in Test KeypadRemote Signals.

5 Fire, fault,Activated, Faulty/Disabled,Internal controls at level 3 Supply Healthy,Test Mode,PSU voltage control Disabled, ARW, PSU, EarthBuzzer volumeLink selectorsKeypad ProgramingTest mode with/without sounders,Select Test ZoneSelect sounder walk testZone disableSounder disableFault latchSuitabilityConventional Twin Wire Smoke/Heat Detectors:NittanSensortec, STB-4SD schottky baseSmoke/Heat Detectors:ApolloSeries 60 &65, 45681-202 BaseApolloSeries 60 &65, 45681-201 schottky baseHochikiCDXrange, YBO-R-5 PABaseHochikiCDX range, YBO-R-5SK schottky baseBreak Glass Call Point:WR2013-SR polarised 470 CDX range, YBO-R-5ZD zener baseSounders:Use polarised and suppressed, light current 24 VCall Point:KACWR2072-SR 470DC electronic sounders or bells (Besson, Fulleon,Sounders:Use polarised and suppressed, light current 24 VSynchrobell etc)DC electronic sounders or bells (Besson, Fulleon,Synchrobell etc)Compact1 zonehy-specFCPENV1 (inc.)

6 1 zone)= 2 zoneExtendible1 - 4 zonehy-spec4 zonebudgetFCPENV1 EXT(inc. 1 zone)FCPENV1 EXT(inc. 1 zone)TPCENV1 ZTPCENV1 ZTPCENV1Z++++TPC ENV 3Z= 3 zone= 4 zone= 4 zoneNB. Extension cards purchased seperately