Example: bachelor of science

Switching Power Supply 24 V DC / 10 A systron PS TSL

650FL_0000424 V DC / 10 ASwitching Power Supplysystron PS TSL+ 24 V DC (L +)+ 24 V DC (L -)DimensionsThe Switching Power supplies, systron PS TSL, offer manyadvantages over conventional Power supplies:DIN Rail mount compact modulesLow weightHigh efficiencyLow heatingWide range of Supply voltageConstant output voltageUL, cUL listed, EN 50178 (VDE 0160)Short-circuit and overload protectionFused inputAdjustable output voltageParallel operation up to 5 Power suppliessystron PS TSL 24 V DC / 10 A2 423 415 00 Approvals:Technical dataPower Supply systron PS TSLP/N:InputSupply / V AC autorangeFrequency, AC 63 HzOutput load hold time With input voltage drop out, min.

650 FL_00004 Switching Power Supply 24 V DC / 10 A systron® PS TSL + 24 V DC (L +) + 24 V DC (L -) Dimensions The switching power supplies, systron® PS …

Tags:

  Switching, Power, Supply, Switching power supply 24 v

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Switching Power Supply 24 V DC / 10 A systron PS TSL

1 650FL_0000424 V DC / 10 ASwitching Power Supplysystron PS TSL+ 24 V DC (L +)+ 24 V DC (L -)DimensionsThe Switching Power supplies, systron PS TSL, offer manyadvantages over conventional Power supplies:DIN Rail mount compact modulesLow weightHigh efficiencyLow heatingWide range of Supply voltageConstant output voltageUL, cUL listed, EN 50178 (VDE 0160)Short-circuit and overload protectionFused inputAdjustable output voltageParallel operation up to 5 Power suppliessystron PS TSL 24 V DC / 10 A2 423 415 00 Approvals:Technical dataPower Supply systron PS TSLP/N:InputSupply / V AC autorangeFrequency, AC 63 HzOutput load hold time With input voltage drop out, min.

2 20 ms at 100% loadInput current at nominal loadmax. A (93 V)/typ. A (115 V)/typ. A (230 V)Inrush current 25 C ( 1 ms)69 A (230 V)Internal input fuse4 A (slow blow)OutputOutput voltage24 V DC 1 %( V adjustable with insulated screwdriver)Output current / Power 60 CT > 60 CT = 70 CVin = V AC10 A-2 %/ C8 AVin = V AC10 A-2 %/ C8 AResidual ripple / noisemax. 50 mVppDeviation of output with input changemax. %Deviation of output with load change 10-90 %max. % ( % parallel operation)Short circuit protectionovercurrent limiting with automatic restartOverload protectionovercurrent limiting (constant current typ.)

3 110 % Iout)Overvoltage protectiontriggerpoint at typ. 140 % nom. output voltageParallel operation (option)up to 5 modules (must be enabled by internal jumper)Norms, testsElectrical safety standards, approvalsEN 50178 (VDE 0160)/EN 60950/UL 508/UL 1950 Galvanic isolationreliable isolation acc. to EN 60950 Voltage withstand input <-> output3 kV AC type testClearance and creepage distances according toovervoltage category 2, pollution degree 2 Electromagnetic immunity (EMI) in acc. to EN 50082-2:ESD:EN 61000-4-2 level 36/8 kVRF field:EN 61000-4-3 level 310 V/mBurst:EN 61000-4-4 level 32 kVSurge:EN 61000-4-5 level 42/4 kVconducted RF:EN 61000-4-6 level 310 VElectromagnetic compatibility (EMC) in acc.

4 EN 50081-2radiated noise EN 55011/EN 50022, class BInput current harmonics-Protection against contactTerminalsIP 20 HousingIP 20 Protection class1 General characteristicsEfficiency (nominal load)typ. 90 % (230 V)Status indicationgreen LED, Power OKOperating temperature-25 .. +70 CStorage temperature-25 .. +85 CTerminalsscrew terminals, 12 AWG ( mm2)Weightapprox. kg ( Ib)Dimensions (W x H x D) x x " (100 x 125 x 125 mm)Mounting hintsNormal position: horizontal onto DIN rail. Spacing to othermodules: both sides min. 5 cm, vertical distances min. 8 " "Note: Adjustable output voltage from 24 to 28 V DCGroundNeutralPower highSupply voltage010103


Related search queries