Example: barber

SY-780/A Product Manual

SY-780/AProduct ManualSynel Industries Industries 4/9/03. Part no (SY-780-222-02) 650-135 This model is competible with PCB no. 770888-01-CAll rights reserved. 1996-2001 Synel Industries Ltd. Reproduction oruse, without express permission of editorial or pictorial content, in anymanner is prohibited. No patent liability is assumed with respect to theuse of the information contained herein. While every precaution has beentaken in the preparation of this Manual , Synel Industries Ltd. assumes noresponsibility for errors or omissions. Neither is any liability assumed fordamages resulting from the use of the information in this brochure are for illustration purposes only. SY- is atrademark of Synel Industries Ltd. All trade names referenced herein areeither trademarks or registered trademarks of their respective companies. Terminology used in this manualWarningTo warn readers about possible damage to equipment or data or about potential problems in the outcome of what they are warn readers about the possibility of minor injury to themselvesor emphasize points or remind readers of something, or to indicate minor problems in the outcome of what they are Industries of contentsTable of Specifications.

Synel Industries Ltd. 1 SY-780/A Introduction 1. Introduction The Synel SY-780/A Terminal is the latest addition to the ever-growing range of Time and Data Collection Systems developed and manufactured by Synel

Tags:

  Manual, Product, Introduction, Sy 780 a product manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SY-780/A Product Manual

1 SY-780/AProduct ManualSynel Industries Industries 4/9/03. Part no (SY-780-222-02) 650-135 This model is competible with PCB no. 770888-01-CAll rights reserved. 1996-2001 Synel Industries Ltd. Reproduction oruse, without express permission of editorial or pictorial content, in anymanner is prohibited. No patent liability is assumed with respect to theuse of the information contained herein. While every precaution has beentaken in the preparation of this Manual , Synel Industries Ltd. assumes noresponsibility for errors or omissions. Neither is any liability assumed fordamages resulting from the use of the information in this brochure are for illustration purposes only. SY- is atrademark of Synel Industries Ltd. All trade names referenced herein areeither trademarks or registered trademarks of their respective companies. Terminology used in this manualWarningTo warn readers about possible damage to equipment or data or about potential problems in the outcome of what they are warn readers about the possibility of minor injury to themselvesor emphasize points or remind readers of something, or to indicate minor problems in the outcome of what they are Industries of contentsTable of Specifications.

2 Technical and interface Physical Power Communication and Selection of the data entry function .. Back panel for Audible Front panel .. Bottom connector Internal .. Contents .. Mounting the SY-780/A terminal on a wall .. Communication Mode (Setup).. - Host Computer Installing communication Connecting your PC to the SY-65 .. Connecting the SY-65 to a connection box .. Making a multi-drop SY-780/A to the RS-232 PC port direct Industries of contentsSY-780 Terminal Calibrating the Real Time Clock (RTC) .. How to cause the memory to Formatting the memory if a crash Fingerprint sensor cleaning and Connectors ..31 Internal connectors ..35 Comunication card Card ..40 Biometric Industries IntroductionThe Synel SY-780/A Terminal is the latest addition to the ever-growing rangeof Time and Data Collection Systems developed and manufactured by SynelIndustries Ltd.

3 The newest member in the family of the 7xx newly developed SY-780/A is designed for effective time & attendancemonitoring, production floor control, job costing, and access control applica-tions. In addition, SY-780/A offers four mediums of access input: Fingerprintverification, magnetic card, bar code, and proximity SY-780/A communicates in a real time interface with Ethernet/tokenring databases, using TCP/IP or UDP protocols. Thus, the SY-780/A is acomprehensive interactive system. It provides online system management ofemployee reports as well as communication of current employees communication programming employs Synel's state-of-the-art user-friendly interface provided by SYncomm or other advanced wide range of compatible communication applications supported by theSY-780/A terminal enables easily customizing the terminal to your uniquerequirements.

4 Synel's SAL compiler enables flexible s mechanical design offers powerful yet easy programming whilethe back light and 32 character display allow quick and easy reading. Thesolid plastic casing and overall structure, make installation in an industrialenvironment simple and Industries SpecificationsSY-780/A2. Technical Technical and interface specifications 32 character LCD with back light display Eight programmable function keys Ten numeric keys Four special function keys: Escape, Return, dot and clear Two browsing keys Badge Reader [Magnetic, Bar code, or proximity depends on the termi-nal type] 512K of protected RAM Protected Real Time date/time clock Rechargeable backup battery (one month capacity) for the memory and Real Time clock Rechargeable backup battery for operation with auto shut-off for use during power outages RS-232 and RS-485 communication Two relays for bell, door, etc Two sensors (door monitoring) Variable baud rate - 1200 to 19200 bpsSynel Industries Options Fingerprint reader- Template size 400 bytes- Response time 3 seconds max- Security level 5- Template storage - 4000- False accept/reject - Bar-code slot reader model (Code 128, code 2 of 5, Code 39, UPC-A) Magnetic (Track II, Track I) Proximity reader (125 KHz)

5 Mifare reader ( MHz) Wiegand 26bit, 37bit (Ver ) Touch memory 2400/14400 bps internal modem Net connection (Ethernet & Token Ring)- Flexible, well- developed IP protocol stack- Ethernet (10 BASE-T/100 BASE-T or AUI) or Token Ring (STP/ UTP)- Telnet and SNMP Physical characteristics Dimensions: Height - cm Width - cm. Depth Power Requirements Voltage: 115/230 VAC Back-up battery - rechargeable, included4 Synel Industries SpecificationsSY-780 Communication and Communication parametersCommunication between the host and terminals is performed under an asyn-chronous mode. The baud rate is programmable, enabling rates from 1200 to19200 Multiple terminal configurationRS-485 communication enables you to connect up to 32 terminals to a singleCOM port and/or to extend the cabling distance to up to 1,000 meters (3,280feet) using 9600 baud via an RS-485 multi-drop line.

6 RS-485 communicationuses two wires as opposed to RS-422 communication, which uses four Port to port configurationA single SY-780/A terminal, equipped with RS-232 communications, can beconnected directly to an asynchronous RS-232 port. If RS-232 communica-tion is used, only one terminal may be connected to each COM port andcabling distances should not exceed 50 meters (160ft). Network connectionsIt can be connected to an Ethernet communications network or Token this type of communication, an IP address is required for every SY-780/Aterminal, making it possible to communicate with each terminal in Selection of the data entry functionThe SY-780/A terminal is ready for operation when a data entry function hasbeen selected (after it was programmed). The prompt of the selected functionwill be displayed on the second line. To select a function, press the desiredfunction key prior to entering the Industries Back panel for mountingThe SY-780/A has a removable square back panel with a hole in each panel is used as a base for fastening the terminal to the Audible responsesWhen SY-780/A reads a fingerprint or a card, an audible response indicatesthat the action was confirmed/verified or Approval toneA long high pitched beep indicating the SY-780/A terminal accepts anemployee Error toneA series of short high pitched beeps indicating there is a problem with aclock-in Industries DescriptionSY-780/A3.

7 Physical DescriptionThe SY-780/A terminal series is enclosed in a rugged plastic molded casingand is secured to the wall using four screws and a removable Front panel1. A 32 character LCD with a back light display is located in the upper part of the front panel. Two arrow keys are located to the right of the display panel for line up and line down Eight function keys are located on the left, below the display, and are marked as follows: IN-,OUT- , F1, F2, F3, F4, F5, and A numerical keyboard of fourteen keys, including Return, Escape, and Clear are located in the lower center of the front Industries Description4. The Alarm light is located to the left of the display. The alarm light is a LED that lights when at least half of the memory is used; it blinks when the memory is full or when the terminal has not been The ON button enables a 15 seconds (modifiable using program) Manual The fingerprint s drive ring on the right side of the SY-780/A .

8 The internal badge reader/bar code/proximity is located below Bottom connector panelThe connector panel is located at the lower part of the casing, withholding thesocket openings for all external connections as follows:1. Power supply2. External secondary Reader3. I2C I/O Extension (N/A)4. Network5. Connector cover 6. Serial I Serial port connection for printer7. Host RS-232 Internal Battery back-up modulesThe SY-780/A has two back-up battery modules, one for the real time clockmemory and the other for operation during a power standard memory back-up module is a lithium battery, which will keepthe internal clock running and the memory intact, for 30 days during a back-up battery provided (in addition to the standard memory back-up) isa self-recharging system which allows the terminal to be operated during apower failure.

9 The battery provides power for one and a half net hours of shut down timeout feature enables the terminal to operate for more8 Synel Industries DescriptionSY-780/Aextended periods of a power failure, the user presses the battery key to activate the termi-nal. Data can then be entered and stored in the SY-780/A memory. The time-out will cause the terminal to shut down automatically after the last use of theterminal, until the battery key is pressed MemoryAs a standard feature, the SY-780/A Terminal contains a 512 Kbyte usermemory, providing storage for data from more than 10,000 simple number depends on the length of the programming tables contained inthe memory, and the complexity of the collected RS-232/485 internal CardThis card provides an RS-232/485 serial Industries UnpackingNote: Do not throw away the box or packing the box and contents for signs of damage that may have occurred dur-ing shipment.

10 After checking the box, carefully unpack and check for the fol-lowing ContentsThe SY-780/A package contains: 1 SY-780/A terminal Mounting panel 1 control badge 1 connecting/splitter box (included only when TCP/IP is not available) Short RS-232/485 communication cable (included only when TCP/IP is not available) Short TCP/IP communication bridge cable (included only when TCP/IP is available) Four Phillips flat head and anchors, for terminal mounting purpose Mounting template Connector cover10 Synel Industries Mounting the SY-780/A terminal on a wallMake sure the unit is not plugged into a power source. If you have alreadyconnected your terminal to a PC, disconnect it. You can reconnect it after youhave completed mounting the : The terminal contains computer components. It should not be mounted where it will be exposed to extreme heat or cold, water, steam, violent vibrations, high electromagneticradiation including high voltage power lines and electrical 1: Select an appropriate location for the SY-780/A should be mounted at employee eye-height.