Example: stock market

System Invacare® HomeFill® Oxygen

Invacare HomeFill Oxygen System Model IOH200. en Compressor User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference. 2015 Invacare Corporation All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by and . All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. 3-in-1 oil is a registered trademark of American Home Products Corporation. WD-40 is a registered trademark of the WD-40 Company. Updated versions of this manual are available on Replacing the Fuse.

Invacare® HomeFill® Oxygen System ModelIOH200 en Compressor UserManual ThismanualMUSTbegiventotheuseroftheproduct. BEFOREusingthisproduct,readthismanualandsaveforfuturereference.

Tags:

  Variance

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of System Invacare® HomeFill® Oxygen

1 Invacare HomeFill Oxygen System Model IOH200. en Compressor User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference. 2015 Invacare Corporation All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by and . All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. 3-in-1 oil is a registered trademark of American Home Products Corporation. WD-40 is a registered trademark of the WD-40 Company. Updated versions of this manual are available on Replacing the Fuse.

2 25. Contents 6 After Use .. 26. Disposal .. 26. 1 General .. 4. 7 Troubleshooting .. 27. Symbols .. 4. Indicator Lights .. 27. Intended Use .. 5. Troubleshooting .. 28. 2 Safety .. 7. 8 Technical Data .. 31. General Guidelines .. 7. Technical Description .. 31. Label Locations .. 10. Specifications.. 31. Dealer Information .. 11. Double-Insulated Products .. 11 9 Warranty .. 33. EMC Information .. 11 Limited Warranty .. 33. 3 Setup .. 13. Unpacking .. 13. Compressor Initial Setup Checklist .. 13. Choosing a Location .. 14. Transporting the Compressor .. 14. Installing the Power Cord.. 15. Connecting the Compressor to the Concentrator .. 16. 4 Usage .. 17. Compressor Operation Checklist.

3 17. Cylinder Prefill Inspection.. 17. Connecting the Cylinder to the Compressor .. 19. Disconnecting the Cylinder from the Compressor .. 20. Turning the Compressor On and Off .. 21. 5 Maintenance .. 23. Maintenance Info .. 23. Wear and Tear .. 23. Service Life .. 23. Cleaning the Compressor Filter .. 23. Cleaning the Cabinet .. 24. Invacare HomeFill Oxygen System 1 General Symbols on the Product The following symbols are found on the compressor, compressor Symbols packaging or the Oxygen cylinder. Symbols in the Manual Read the Manual (Compressor). Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage.

4 See the information below for definitions of the signal words. Read the Manual (Cylinder). DANGER! Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Electrical Hazard WARNING! Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Alternating Current Type BF equipment Applied Parts CAUTION! Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage Power switch ON . or minor injury or both. IMPORTANT Power switch OFF . Indicates a hazardous situation that could result in damage to property if it is not avoided. Gives useful tips, recommendations and information for DO NOT smoke efficient, trouble-free use.

5 4 1100873-L-06. General No Open Flame Intended Use WARNING! The use of this device is limited to refilling a specific Class II, Double Insulation. Refer to patient's own Oxygen cylinders. The designated Double-Insulated Products, page 11. cylinders MUST be used ONLY by the specific Oxygen patient and are not to be distributed to any other Keep dry in transport or storage and individual for any purpose. during use No other use of this device is indicated. Fuse WARNING! Risk of Death, Injury or Damage Oxidizer The Invacare HomeFill compressor was designed to be used only with Invacare Oxygen concentrators. Use with other types of devices may cause injury, death or property damage. Transport and Storage Temperature DO NOT use the Invacare HomeFill compressor with anything other than an Invacare Oxygen concentrator.

6 Use only with specially designed Invacare Oxygen Transport and Storage Humidity concentrators that are HomeFill compatible. To determine if your Oxygen concentrator is HomeFill compatible, Recycle this product. Refer to Disposal, examine the lower right corner of the rear of the Oxygen page 26. concentrator A for an outlet fitting B. 1100873-L-06 5. Invacare HomeFill Oxygen System Platinum Top View Perfecto2 Rear View The intended use of an Invacare HomeFill compressor is an accessory device to an Invacare Oxygen concentrator that enables the patient to refill custom portable Oxygen cylinders for personal use. This product is intended for single patient use in the indoor homecare environment only and is not to be used for bulk cylinder refilling.

7 No specific product knowledge or training is required, other than what is contained in this manual, to operate the product. It is not intended for supplying Oxygen therapy during refilling. This product is intended to be used by or under adult supervision only after reading and understanding the instructions and warnings of this user manual. 6 1100873-L-06. Safety 2 Safety DANGER! Risk Of Death, Injury, Or Damage From Fire Textiles, oil or petroleum substances, grease, greasy General Guidelines substances and other combustibles are easily ignited DANGER! and burn with great intensity in Oxygen enriched air and Risk Of Death, Injury, Or Damage when in contact with Oxygen under pressure.

8 To avoid Improper use of the product may cause death, injury or fire, death, injury or damage: damage. This section contains important information for DO NOT SMOKE while using this device. the safe operation and use of this product. DO NOT use near OPEN FLAME or IGNITION. DO NOT use this product or any available optional SOURCES. equipment without first completely reading and DO NOT use any lubricants on the compressor unless understanding these instructions and any additional recommended by Invacare. instructional material such as user manuals, service NO SMOKING signs should be prominently displayed. manuals or instruction sheets supplied with this Avoid creation of any spark near Oxygen equipment.

9 Product or optional equipment. This includes sparks from static electricity created by If you are unable to understand the warnings, cautions any type of friction. or instructions, contact a healthcare professional, Keep all matches, lighted cigarettes or other sources dealer or technical personnel before attempting to of ignition out of the room in which this compressor use this equipment. is located and away from where Oxygen is being Check ALL external components and carton for delivered. damage. In case of damage, or if the product is not Keep the Oxygen tubing, cord, and compressor out working correctly, contact a technician or Invacare from under such items as blankets, bed coverings, for repair.

10 Chair cushions, clothing, and away from heated or hot In order to ensure the safe installation, assembly surfaces including space heaters, stoves, and similar and operation of the HomeFill Compressor these electrical appliances. instructions MUST be followed. THE INFORMATION IN THIS DOCUMENT IS. SUBJECT TO CHANGE WITHOUT NOTICE. 1100873-L-06 7. Invacare HomeFill Oxygen System DANGER! DANGER! Risk Of Death, Injury, Or Damage From Fire Risk of Electric Shock Textiles, oil or petroleum substances, grease, greasy This unit contains moving and high pressure components. substances and other combustibles are easily ignited There are no user serviceable parts inside the cover. To and burn with great intensity in Oxygen enriched air and avoid electric shock, injury or death: when in contact with Oxygen under pressure.


Related search queries