Example: bankruptcy

Table Of Contents - Markel Mechanical Distribution …

1 Table Of Contents Note: The information contained herein is deemed to be as accurate as possible upon the time of printing. However, to insure that you receive the most reliable information contact the factory should a question arise. All prices are given in Dollar : 1-800-682-3398. Copyright 2018; TPI Corporation.*Products listed in this section are custom built and subject to 100% cancellation/restocking chargesCATEGORYPageAMPERAGE CHART & WARRANTY2 ELECTRIC HEAT COMFORT ZONES3 HAZARDOUS LOCATION & WASHDOWNHLA*Hazardous Location Fan Forced4-7 PHLA*Portable Hazardous Location Fan Forced7 FEP*Hazardous Location Convector8-95500*Washdown Fan Forced10-11 UNIT HEATERSUHH orizontal Fan Forced12-135100 Horizontal or Vertical Fan Forced14-192600 Downflow Fan Forced20-225700 Confined Space Plenum Rated225600 Multiple Wattage Fan Forced236300 Cabinet Fan Forced24-27 WALL CONVECTORS8500*Commercial Slope Top 28-298800*Institutional30-314100*Recesse d Commercial32-33 CEILING & COVE 3000 Fan Forced343380 Commercial Fan Forced343480*Commercial Recessed Fan Forced353470*Commercial Surface Fan Forced36CP/RCPR adiant Ceiling Panel37 CVXR adiant Cove38 WALL HEATERS3000 Commercial Midsized Fan Forced394400 Commercial Low Profile Fan Forced393320 Commercial Fan

1 Table Of Contents Note: The information contained herein is deemed to be as accurate as possible upon the time of printing. However, to insure that you

Tags:

  Information, Content, Table of contents, Table

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Table Of Contents - Markel Mechanical Distribution …

1 1 Table Of Contents Note: The information contained herein is deemed to be as accurate as possible upon the time of printing. However, to insure that you receive the most reliable information contact the factory should a question arise. All prices are given in Dollar : 1-800-682-3398. Copyright 2018; TPI Corporation.*Products listed in this section are custom built and subject to 100% cancellation/restocking chargesCATEGORYPageAMPERAGE CHART & WARRANTY2 ELECTRIC HEAT COMFORT ZONES3 HAZARDOUS LOCATION & WASHDOWNHLA*Hazardous Location Fan Forced4-7 PHLA*Portable Hazardous Location Fan Forced7 FEP*Hazardous Location Convector8-95500*Washdown Fan Forced10-11 UNIT HEATERSUHH orizontal Fan Forced12-135100 Horizontal or Vertical Fan Forced14-192600 Downflow Fan Forced20-225700 Confined Space Plenum Rated225600 Multiple Wattage Fan Forced236300 Cabinet Fan Forced24-27 WALL CONVECTORS8500*Commercial Slope Top 28-298800*Institutional30-314100*Recesse d Commercial32-33 CEILING & COVE 3000 Fan Forced343380 Commercial Fan Forced343480*Commercial Recessed Fan Forced353470*Commercial Surface Fan Forced36CP/RCPR adiant Ceiling Panel37 CVXR adiant Cove38 WALL HEATERS3000 Commercial Midsized Fan Forced394400 Commercial Low Profile Fan Forced393320 Commercial Fan

2 Forced403420/50 Heavy Duty Fan Forced; Setback41-433310 Residential/Commercial Fan Forced44-453200 Midsized Fan Forced464300 Low Profile Fan Forced474800 Register Style Fan Forced48 ARCHITECTURAL SILL LINEG eneral Product Information499100*Radius Front Draft Barrier50-519300*Radius Front Draft Barrier52-53 DBF/DBT*3 1 8 x 4 1 2 Convector54 RDBT*7 x 6 Convector (Round)54 ASHDB*5 1 2 x 8 thru 20 Tall Convector55 BASEBOARD HEATERS3900 Hydronic Electric593700 Architectural Style Electric57 Hydronic/Architectural Accessories582900 SStainless Steel Element Electric592900 CHeavy Duty Commercial Electric60 Electric Baseboard Accessories61 ELECTRIC INFRARED HEATERSE lectric Infrared Product Information62-63 FSSH eavy Duty Flat Panel Emitter64-65 FSAA rchitectural Flat Panel Emitter66-67TH & THSSMul-T-Mount68-73 THAMul-T-Mount74-75 OCHO utdoor/Indoor Rated Quartz76-77 RPHO utdoor Rated Stainless Steel78 MMMitey Midget78 FFHU tility 78 CATEGORYPageELECTRIC INFRARED HEATERS, CONTINUEDE lements, Accessories.

3 & Controls79-81*ICP*Infrared Control Panels82-83 FSPH eavy Duty Flat Panel Emitter84CH120/240V Quartz Infrared85 PCHP ortable Quartz Infrared Spot Heater85 RHGP ortable Infrared Instant On-Off Heat Gun85 HPPortable Electric Infrared Heat Panels85 PORTABLE HEATERSFES & YESS alamander Heat WaveTM86-87150-TS120V Electric Portable Heater87198120V Fan Glo87178120V Ceramic88188120V Milk House88E3915120V Hydronic Baseboard88483120V Baseboard89474240V Dual Heat Fan Forced895800240V Garage/Workshop89 ICH240V Construction/Utility90680240V Heavy Duty90170-TS120V Confined Space90 SPECIALTY HEATERSRPHPump House91 FHIn-Floor Fan Forced91 TSHKick-Space Fan Forced91 AIR CURTAINCF-C2 Speed Commercial Air Curtain92CF/CFH*Variable Speed Air Curtain 92 THERMOSTATSET5 Line Voltage, 22A, 120-277 VAC93ET9 Line Voltage, 22A, 277 VAC93 EPET / HLTLine Voltage, Haz. Loc., 120-277 VAC932000 Line Voltage, 22A, 120-277 VAC94 TWLine Voltage, 120-277 VAC94 CKT / KTLine Voltage, 120-250 VAC95 LBBi-Metal In-Built95 LRBi-Metal Outdoor95 RHAir Flow / Differential Pressure Switches95 Differential Pilot Tubes95 HHumidistat/DeHumidistat, 24-240 VAC96 RFLow Voltage, Wireless96 TLine Voltage, Precision, 120-277 VAC96 TLLine Voltage, Programmable96 THLow Voltage, Programmable97 TWLow Voltage, 2 Stage97 TGThermostat Guards97 SDClever Comfort Setback on Demand98-101 UTLow Voltage, Vertical/Horizontal Voltage, Square10224 ALow Voltage Relays102 THERMAL AREA TREATMENTTATT hermal Area Treatment/Accessories103 HRHot Room Heaters103 DUCT HEATERSHP*HotPod Resi.

4 Supplemental Duct Heat104-1055700 Confined Space Plenum Rated1067200/7300*Plenum Heaters106-109PD*Packaged (preconfigured) Duct Heat110 CHMS*Enclosed Finned Tubular Element111HF*Open Coil Element112-113 MFH*Fan Coil Units114-118 PRODUCT INDEX2 Amperage Chart & Electric Heat Products Limited WarrantyHeat ProductsElements in 2900 Series Baseboard10 YearsAll Other Heating Products1 YearThermostats & Controls2 Volt AMP Rating220 Volt AMP Rating230 Volt AMP Rating240 Volt AMP Rating277 Volt AMP Rating440 Volt AMP Rating480 Volt AMP Rating550 Volt AMP Rating1 PH3 PH1 PH3 PH1 PH3 PH1 PH3 PH1 PH3 PH3 PH3 , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , : All custom built products are subject to 100% cancellation/restock addition to the Limited Warranty stated to the right covering general products, TPI Corporation extends this warranty on the following listed products, which are warranted to the original consumer from the original date of purchase for the total time periods indicated herein below:TPI Corporation provides a limited warranty of materials and workmanship for a period of (i) ten (10) years for elements in 2900 Series baseboard heaters, (ii) two (2) years for Thermostats and Controls, (iii) five (5) years on HD and HDH series fans, (iv) three (3) years on UHP and IHP series fans, (v) and twelve (12) months for all other products, with the warranty period commencing on the original date of purchase.

5 The TPI warranty is limited to materials manufactured and work performed by TPI Corporation, and does not include damage or failure caused by acts of God, abuse, misuse, connected to or placed on other than rated voltage, abnormal usage, faulty installation, failure to follow suggested maintenance procedures enclosed with the product, improper maintenance or any repairs other than those provided by an authorized TPI Corporation service center. For the name of your nearest authorized TPI Corporation service center, please write to TPI Corporation, Box 4973, Johnson City, Tennessee, 37602 or call the warranty period, TPI Corporation will, at its sole option, repair or replace any defective parts or products returned, freight prepaid, to the TPI Corporation factory or such other location as TPI Corporation may designate. No parts or products will be accepted for repair or replacement without prior authorization from TPI Corporation and a return merchandise authority (RMA) number issued by TPI Corporation.

6 Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit. When returning parts, the owner must provide the model number of the product and nature of difficulty being warranty does not obligate TPI Corporation to bear the cost of labor in replacing any assembly, unit or component part thereof, nor does TPI Corporation assume any liability for secondary charges, expenses for installing or removal, freight or damages. There will be charges rendered for product repairs made after the warranty period has expired. Proof of purchase, including date, must accompany request for in-warranty service. This warranty gives you specific legal rights and you may have other rights, which may vary, from state to for the limited warranty provided in the foregoing paragraph, all parts and products sold by TPI Corporation are sold as is , where is , and without any other warranty of any kind or nature, whether express, implied, or statutory and including, without limitation, any implied warranty of specific performance or merchantability.

7 Under no circumstances, even with respect to claims covered by the foregoing warranty, will TPI Corporation be responsible for any incidental, consequential, special, or punitive damages of any kind or nature arising from or related to the parts or products sold by TPI Corporation. In any event, TPI Corporation s maximum liability shall not in any case exceed the purchase price for the part or product claimed to be defective. You hereby expressly agree to waive any and all rights to a trial by jury with respect to any product manufactured or supplied by TPI Heat Comfort Zones* R values are industry standards for insulation effectiveness. Ask company representative for assistance if you do not know R for your present structure StandardMinimum: Not RecommendedCeiling*R-24*R-19*R-11 WallsR-1311R-7 FloorR-24 11----ZONEAPPROXIMATE WATTAGE NEED PER SQUARE or wall mount style? Recessed or surface type?

8 It s easy to select the heater that s right for Measure the size of the room(s) or area you intend to heat for square footage. You will need the length times the width to get this Find your location on the map above. This determines your basic heating The chart shown below the map lists insulation values based on the effectiveness of the insulation presently in your home. Find your heating zone on the chart and the approximate wattage per square foot you will Multiply the total number of square feet you intend to heat by the approximate wattage per square foot you just obtained. This will determine your total heating requirement in watts for the Much Heat is Right For You? Figures are based on 15% total window and door openings in outside walls, and 3/4 total home air changes per hour. Typical frame-type construction with unheated basement or unventilated crawl space. If you do not have storm doors and windows, add 30% to the watts per square foot (multiply by ).

9 That s all there is to it! Now choose the heater with a wattage equal to what you need. Your final selection will, of course, depend on available wall space, window placement, Calculation: Example = 10 x 12 room in Zone 3 with FHA standard insulation 1. Determine room square footage: 10 x 12 = 120 sq. ft. 2. Zone 3 with FHA standard insulation requires watts per sq. ft. 3. Multiply square footage of room to be heated by the approximate wattage per square foot required. 120 sq. ft x watts = 984 watts required. From this calculation it can be reasoned that a 1000 watt heater would be Series Hazardous Location Fan Forced Unit HeaterFAN-FORCED SUSPENDED UNIT HEATERS 3-25 KW FOR T-3B CLASS I, GROUP C & D, DIVISION 1 & 2 AND CLASS II, GROUPS E, F & G, DIVISIONS 1 & with optional pilot light and disconnect switchHeat Exchanger and Elements: Heavy walled, painted carbon steel with aluminum fins liquid heat exchanger, liquid filled with three-immersion type copper sheathed elements.

10 The elements shall have the highest quality nickel-chromium resistance wire encased in a magnesium oxide dielectric and be hermetically sealed into the heat exchanger core. The heat transfer fluid is Ethylene-glycol solution for operation to -49 degrees F ( 45 degrees C). Stainless steel and aluminum pressure relief valve for Cutout High Limit Protection and Optional Pilot Light: The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid filled heat exchanger. An optional pilot light to indicate manual reset tripped, if safe operating temperatures are exceeded, is located on control : The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for hazardous location and operate at rated voltage of heater, 60 Hz, 1725 Enclosure: All controls shall be factory installed and wired in a hazardous location enclosure.


Related search queries