TABLE OF CONTENTS . Obsolete TYPES. Crouse-Hinds .. 2. Cutler-Hammer .. 3. Federal Pacific .. 6. Frank Adam Electric .. 9. General Electric .. 11. I-T-E .. 13. Murray.. 2. Square D .. 17. Sylvania / GTE Sylvania / Challenger .. 19. Trumbull Electric .. 21. Westinghouse .. 22. Zinsco .. 26. MOUNTING HARDWARE KITS1 .. 27. Terms and Conditions TRANSPORTATION CHARGES - Freight will be prepaid and added to invoice on all shipments of molded case Circuit Breakers , bus plugs and all other electrical apparatus. MINIMUM BILLING - NONE. PAYMENT - We accept VISA, MASTERCARD, DISCOVER, and AMERICAN EXPRESS for your accounting convenience.

3 telephone (800) 843-6797 fax (419) 663-6903 customer service: monday - friday 8:00 a.m. - 5:00 p.m. est cutler-hammer obsolete cutler-hammer circuit breakers

Tags:

  Content, Table, Circuit, Obsolete, Table of contents obsolete circuit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TABLE OF CONTENTS - Obsolete Circuit Breakers …

1 TABLE OF CONTENTS . Obsolete TYPES. Crouse-Hinds .. 2. Cutler-Hammer .. 3. Federal Pacific .. 6. Frank Adam Electric .. 9. General Electric .. 11. I-T-E .. 13. Murray.. 2. Square D .. 17. Sylvania / GTE Sylvania / Challenger .. 19. Trumbull Electric .. 21. Westinghouse .. 22. Zinsco .. 26. MOUNTING HARDWARE KITS1 .. 27. Terms and Conditions TRANSPORTATION CHARGES - Freight will be prepaid and added to invoice on all shipments of molded case Circuit Breakers , bus plugs and all other electrical apparatus. MINIMUM BILLING - NONE. PAYMENT - We accept VISA, MASTERCARD, DISCOVER, and AMERICAN EXPRESS for your accounting convenience.

2 Pre-payment by company check, cashier's check or money order is also accepted. RETURNS - All Requisitions for Return Authorization must be filled out in their entirety and be accompanied by a BREAKER KING INVOICE. NUMBER showing date of purchase and your original purchase order number. No returns of any kind will be permitted without properly submitted Return Authorization Request and Return Goods Authorization with proof of purchase. Special-ordered, non-stock merchandise may not be returned under any circumstances. A restock charge of 25% will apply to all returns. Credits will be applied to the credit/debit card account originally charged.

3 PRODUCT AVAILABILITY - This guide is not intended to state immediate availability of products illustrated herein. While our inventories are extensive they are in no way complete. All In-Stock items are subject to prior sale. Pricing quotes therefore, are strictly subject to item availability. Pricing will vary for newly acquired or sourced product. 1. Obsolete CROUSE-HINDS Circuit Breakers . CROUSE-HINDS. CROUSE-HINDS TYPE MP. 120/240 VAC CROUSE-HINDS TYPE MP/MP-R. MAGNETIC-HYDRAULIC 120/240 VAC. 1 POLE. 15, 20, 30, 40, 50 2 POLE ONLY. 110, 125. 2 POLE. 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100.

4 CROUSE-HINDS TYPE MH. 120/240 VAC HALF-SIZE CROUSE-HINDS TYPE MD-H. 120/240 VAC MAIN BREAKER. 1 POLE. 15, 20, 30. 2 POLE ONLY. 2 POLE 150, 175, 200. 15, 20, 25, 30, 40, 50. CROUSE-HINDS TYPE ED. CROUSE-HINDS TYPE EP 120/240 VAC. 120/240 VAC 2 POLE (61/2 H x 23/4 W x 23/4 D). THERMAL MAGNETIC 125, 150, 175, 200, 225. 3 POLE ONLY 3 POLE (61/2 H x 4 W x 23/4 D). 15, 20, 30, 40, 50, 60, 70, 90, 100. Obsolete MURRAY Circuit Breakers . MURRAY. You Can Depend on us for Accurate MURRAY TYPE D Identification and Selection 120/240 VAC. of Add-On and Replacement 2 POLE Circuit Protection Devices 125, 150, 175, 200, 225, NON-AUTO.

5 NOTES: TELEPHONE (800) 843-6797 FAX (419) 663-6903. CUSTOMER SERVICE: MONDAY - FRIDAY 8:00 - 5:00 EST. 2. Obsolete CUTLER-HAMMER Circuit Breakers . CUTLER-HAMMER. CUTLER-HAMMER TYPE FS4. CUTLER-HAMMER TYPE CHH 277/480 VAC. 120/240 VAC. 1 POLE (61/8 H x 13/8 W x 33/16 D). 2 POLE (71/2 H x 23/4 W x 27/8 D) 15, 20, 30. 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 2 POLE (61/8 H x 23/4 W x 33/16 D). 15, 20, 30, 40, 50, 60, 70, 80, 90, 100. 3 POLE (71/2 H x 41/8 W x 27/8 D) 3 POLE (61/8 H x 41/8 W x 33/16 D). 60, 70, 80, 90, 100, 125, 150, 175, 200, 225 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100.

6 CUTLER-HAMMER TYPE FS2 CUTLER-HAMMER TYPE FS6. 120/240 VAC 600 VAC. 2 POLE (61/8 H x 23/4 W x 33/16 D) 3 POLE (61/8 H x 41/8 W x 33/16 D). 15, 20, 30, 40, 50, 60, 70, 80, 90, 100 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 100 MCS, 125, 150, 150 MCS. 3 POLE (61/8 H x 41/8 W x 33/16 D). 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100. CUTLER-HAMMER TYPE FH CUTLER-HAMMER TYPE FL. 600 VAC 2P @ 480 VAC 3P @ 600 VAC. 3 POLE (61/8 H x 41/8 W x 33/16 D) 2 POLE (91/3 H x 23/4 W x 33/16 D). 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 15, 20, 30, 40, 50, 60, 70, 80, 90, 100.

7 90, 100, 125, 150. 3 POLE (91/3 H x 41/8 W x 33/16 D). 15, 20, 25, 30, 35, 40, 45, 50, 60, 70. CUTLER-HAMMER TYPE JS CUTLER-HAMMER TYPE JH. 600 VAC 600 VAC. 3 POLE 3 POLE. 100, 125, 150, 175, 200, 225, MCS 100, 125, 150, 175, 200, 225. (12 H x 41/8 W x 313/16 D) (12 H x 41/8 W x 313/16 D). CUTLER-HAMMER TYPE KS2. CUTLER-HAMMER TYPE JL 240 VAC. 600 VAC CURRENT-LIMITER. 2 POLE (3 POLE FRAME). 3 POLE 250, 300, 350, 400. 100, 125, 150, 175, 200, 225. 3 POLE (101/8 H x 51/2 W x 313/16 D). (12 H x 41/8 W x 313/16 D) 250, 300, 350, 400. CUTLER-HAMMER TYPE KS6 CUTLER-HAMMER TYPE KH.

8 600 VAC 600 VAC. 3 POLE 3 POLE. 100, 125, 150, 175, 200, 225, 250, 300, 100, 125, 150, 175, 200, 225, 250, 300, 350, 400, MCS 350, 400. (101/8 H x 51/2 W x 313/16 D) (101/8 H x 51/2 W x 313/16 D). TELEPHONE (800) 843-6797 FAX (419) 663-6903. CUSTOMER SERVICE: MONDAY - FRIDAY 8:00 - 5:00 EST. 3. Obsolete CUTLER-HAMMER Circuit Breakers , cont. CUTLER-HAMMER. CUTLER-HAMMER TYPE LS-A CUTLER-HAMMER TYPE LH-A. 600 VAC 600 VAC. 3 POLE 3 POLE. 250, 300, 350, 400, 500, 600 250, 300, 350, 400, 500, 600. (103/4 H x 81/4 W x 313/16 D) (103/4 H x 81/4 W x 313/16 D). CUTLER-HAMMER TYPE LS-E CUTLER-HAMMER TYPE LSB-E.

9 600 VAC 240 VAC FIXED TRIP. INTERCHANGEABLE TRIP. 2 POLE (3 POLE FRAME) 2 POLE (3 POLE FRAME). 250, 300, 350, 400, 450, 500, 600, MCS 250, 300, 350, 400, 450, 500, 600. 3 POLE (103/4 H x 81/4 W x 313/16 D) 3 POLE (103/4 H x 81/4 W x 313/16 D). 250, 300, 350, 400, 450, 500, 600, MCS 250, 300, 350, 400, 450, 500, 600. CUTLER-HAMMER TYPE LH-E. CUTLER-HAMMER TYPE LSB-E 600 VAC. 600 VAC FIXED TRIP INTERCHANGEABLE TRIP. 3 POLE 2 POLE (3 POLE FRAME). 250, 300, 350, 400, 450, 500, 600 250, 300, 350, 400, 450, 500, 600. (103/4 H x 81/4 W x 313/16 D) 3 POLE (103/4 H x 81/4 W x 313/16 D).

10 250, 300, 350, 400, 450, 500, 600. CUTLER-HAMMER TYPE LL-E CUTLER-HAMMER TYPE MS/MH. 600 VAC 600 VAC. INTERCHANGEABLE TRIP. 2 POLE (3 POLE FRAME). 2 POLE (3 POLE FRAME) 350, 400, 500, 600, 700, 800, MCS. 250, 300, 350, 400, 450, 500, 600. 3 POLE (16 H x 81/4 W x 4 D). 3 POLE (103/4 H x 81/4 W x 313/16 D) 350, 400, 500, 600, 700, 800, MCS. 250, 300, 350, 400, 450, 500, 600. CUTLER-HAMMER TYPE EC. CUTLER-HAMMER TYPE NS/NH 240 VAC. 600 VAC. 2 POLE (61/8 H x 23/4 W x 33/16 D). 2 POLE (3 POLE FRAME) 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 700, 800, 900, 1000, 1200, MCS 90, 100.