Example: bachelor of science

TDF - Lightning and Surge Technologies

EQUIPMENT(1) Opto-coupler output can be connected to DINLINE Alarm Relay (DAR275V) to provide Form C dry contacts.*STATUS SENSE*WARNINGERICO products shall be installed and used only as indicated in erico s product instruction sheets and training materials. Instruction sheets are available at and from your erico customer service representative. Improper installation, misuse, misapplication or other failure to completely follow erico s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright 2008 erico International Corporation. All rights , CADWELD, CRITEC, erico , ERIFLEX, ERITECH, and LENTON are registered trademarks of erico International is a registered trademark of the American National Standards Institute. IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers, Incorporated. NEMA is a registered trademark of the National Electrical Manufacturers Association. UL is a registered trademark of Underwriters Laboratories, Inc.

WARNING ERICO products shall be installed and used only as indicated in ERICO’s product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative.

Tags:

  Erico

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TDF - Lightning and Surge Technologies

1 EQUIPMENT(1) Opto-coupler output can be connected to DINLINE Alarm Relay (DAR275V) to provide Form C dry contacts.*STATUS SENSE*WARNINGERICO products shall be installed and used only as indicated in erico s product instruction sheets and training materials. Instruction sheets are available at and from your erico customer service representative. Improper installation, misuse, misapplication or other failure to completely follow erico s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright 2008 erico International Corporation. All rights , CADWELD, CRITEC, erico , ERIFLEX, ERITECH, and LENTON are registered trademarks of erico International is a registered trademark of the American National Standards Institute. IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers, Incorporated. NEMA is a registered trademark of the National Electrical Manufacturers Association. UL is a registered trademark of Underwriters Laboratories, Inc.

2 FeaturesThe TDF series has been specifi cally designed for process control applications to protect the switched mode power supply units on devices such as PLC controllers, SCADA systems and motor controllers. Units are UL Recognized and available for 3A, 10A and 20A loads and suitable for 110-120V ac/dc and 220-240 Vac TDF is a series connected, single phase Surge fi lter providing an aggregate Surge capacity of 50kA (8/20 s) across L-N, L-PE, and N-PE. The low pass fi lter provides up to 65dB of attenuation to voltage transients. Not only does this reduce the residual let-through voltage, but it also helps further reduce the steep voltage rate-of-rise providing superior protection for sensitive electronic equipment. CRITEC Transient Discriminating (TD) Technology provides increased service life In-line series protection High effi ciency low pass sine wave fi ltering ideal for the protection of switched mode power supplies Three modes of protection: L-N, L-PE & N-PE 35 mm DIN rail mount simple installation LED status indication and opto-isolated output for remote status monitoring CE, UL 1449 Ed.

3 3 ListedCRITEC Transient Discriminating FilterTDF LINEM odelTDF3A120 VTDF3A240 VTDF10A120 VTDF10A240V TDF20A120 VTDF20A240 VItem Number for Europe7000017000027000037000047000057000 06 Nominal Voltage, Un110-120 V220-240 V110-120 V220-240 V110-120 V220-240 VDistribution SystemTN-C-S, TN-SMax Cont. Operating Voltage, Uc170 VAC340 VAC170 VAC340 VAC170 VAC340 VACS tand-off Voltage240V400V240V400V240V400 VFrequency0-60Hz50/60Hz0-60Hz50/60 HzMax Line Current, IL3 A10 A20 AOperating Current @ Un135 mA250 mA240 mA480 mA240 mA480 mAMax Discharge Current, Imax10kA 8/20 s N-PE20kA 8/20 s L-N20kA 8/20 s L-PEProtection ModesAll modes protectedTechnologyIn-line series low pass sine wave fi lterTD TechnologyVoltage Protection Level, Up500V @ 500A250V @ 3kA700V @ 500A600V @ 3kA500V @ 500A250V @ 3kA700V @ 500A600V @ 3kA500V @ 500A250V @ 3kA700V @ 500A600V @ 3kAFiltering-62dB @ 100kHz-65dB @ 100kHz-53dB @ 100kHzStatusGreen LED. On=Ok. Isolated opto-coupler outputDimensions H x D x W: mm (in)90 x 68 x 72 ( x x )90 x 68 x 144 ( x x )Module Width4 M8 MWeight: kg (lbs) ( ) ( ) ( )EnclosureDIN 43 880, UL94V-0 thermoplastic, IP 20 (NEMA -1)Connection1 mm to 6 mm (#18 AWG to #10)Mounting35 mm top hat DIN railBack-up Overcurrent Protection3A10A20 ATemperature-35 C to 55 C (-31 F to 131 F)Humidity0% to 90%ApprovalsC-Tick, CE (NOM 3A, 120V), CSA , UL 1283, UL 1449 Ed 3 Recognized Component Type 2 Surge Rated to MeetANSI /IEEE Cat A, Cat B, Cat CWARNINGERICO products shall be installed and used only as indicated in erico s product instruction sheets and training materials.

4 Instruction sheets are available at and from your erico customer service representative. Improper installation, misuse, misapplication or other failure to completely follow erico s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. Copyright 2008 erico International Corporation. All rights , CADWELD, CRITEC, erico , ERIFLEX, ERITECH, and LENTON are registered trademarks of erico International E800LT07 WWEN is a registered trademark of the American National Standards Institute. IEEE is a registered trademark the Institute of Electrical and Electronics Engineers, Incorporated. NEMA is a registered trademark the National Electrical Manufacturers Association. UL is a registered trademark Underwriters Laboratories, mm90 mm36 mmDSF6A68 mm90 mm72 mmDSF20A*DSF20A275V only LINEF eaturesLNLN**The two port DSF series has been specifi cally designed for process control applications to protect the switched mode power supply units on devices such as PLC controllers, SCADA systems and motor controllers.

5 The 30V unit is suitable for 12V and 24 Vac/dc signaling and control 6A DSF series incorporates a space effi cient, low pass, series fi lter which provides attenuation to high frequency interference. The larger 20A model provides status indication and a higher Surge rating, making this ideal for the protection of higher risk equipment. In-line series protection EMI/RFI noise fi ltering protects against industrial electrical noise Compact design fi ts into motor control and equipment panels Three modes of protection: L-N, L-PE & N-PE 35 mm DIN rail mount simple installation LED power indicatorCRITEC Dinline Surge Filter DSFM odelDSF6A30 VDSF6A150 VDSF6A275 VDSF20A275 VItem Number for Europe702090701000701030701020 Nominal Voltage, Un24110-120 V220-240 VDistribution System1Ph 2W+GSystem CompatibilityTN-S, TN-C-SMax Cont. Operating Volt-age, Uc30 VAC, 38 VDC150 VAC275 VACF requency0-60Hz50/60 HzMax Line Current, IL6 A20 AOperating Current @ Un7 mAMax Discharge Current, Imax4kA 8/20 s16kA 8/20 s15kA 8/20 s L-N15kA 8/20 s L-PE25kA 8/20 s N-PEProtection ModesAll modes protectedTechnologyIn-line series fi lterMOVV oltage Protection Level, Up110V @ 3kA400V @ 3kA750V @ 3kA710V @ 3kAFiltering-3dB @ 300kHz-3dB @ 62kHzStatusLED power indicatorStatus indicatorDimensions H x D x W: mm (in)90 x 68 x 36 ( x x )90 x 68 x 72 ( x x )Module Width2 M4 MWeight: kg (lb) ( ) ( )EnclosureDIN 43 880, UL94V-0 thermoplastic, IP 20 (NEMA-1)Connection1 mm to 6 mm (#18 AWG to #10 AWG)Mounting35 mm top hat DIN railBack-up Overcurrent Protection6A20 ATemperature-35 C to 55 C (-31 F to 131 F)Humidity0% to 90%ApprovalsC-Tick, CE, NOM, UL 1449 Ed 3 Recognized Component Type 2C-Tick, CESurge Rated to MeetANSI /IEEE Cat A, Cat B


Related search queries