Example: quiz answers

Technical Bulletin - TM INOX, Relaţii INOXIDABILE

Climaveneta Technical Bulletin NX_0152P_0812P_201205_EN. NX. 0152P - 0812P Air-source liquid chiller for outdoor installation, with plate heat 39 226 kW exchanger (The photo of the unit is purely indicative and may vary depending on the model). < Electronic expansion valve < Unit with low environmental impact and reduced refrigerant charge < Extensive range of operation < Contributes to achieving LEED points NX. SUMMARY. 1. CERTIFICATION LEED p. 3 11. Technical DATA 11. 2. DESCRIPTION OF THE UNIT 4 12. FAN STRUCTURE AND CONTROL 24. 3. MODELS AND VERSIONS 4 13. OPERATING LIMITS 25. Compact versions with standard efficiency 4. Compact versions with high efficiency 4 14. ETHYLENE GLYCOL MIXTURE 26. 4. HOW TO SELECT THE NX 5 15. FOULING FACTORS 26. 5. CROSS-REFERENCE TABLE 6 16. HYDRAULIC DATA 27. 6. GENERAL CHARACTERISTICS 6 17.

Unit with low environmental impact and reduced refrigerant charge Electronic expansion valve Extensive range of operation Contributes to achieving LEED points

Tags:

  Technical, Refrigerant, Bulletin, Technical bulletin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Technical Bulletin - TM INOX, Relaţii INOXIDABILE

1 Climaveneta Technical Bulletin NX_0152P_0812P_201205_EN. NX. 0152P - 0812P Air-source liquid chiller for outdoor installation, with plate heat 39 226 kW exchanger (The photo of the unit is purely indicative and may vary depending on the model). < Electronic expansion valve < Unit with low environmental impact and reduced refrigerant charge < Extensive range of operation < Contributes to achieving LEED points NX. SUMMARY. 1. CERTIFICATION LEED p. 3 11. Technical DATA 11. 2. DESCRIPTION OF THE UNIT 4 12. FAN STRUCTURE AND CONTROL 24. 3. MODELS AND VERSIONS 4 13. OPERATING LIMITS 25. Compact versions with standard efficiency 4. Compact versions with high efficiency 4 14. ETHYLENE GLYCOL MIXTURE 26. 4. HOW TO SELECT THE NX 5 15. FOULING FACTORS 26. 5. CROSS-REFERENCE TABLE 6 16. HYDRAULIC DATA 27. 6. GENERAL CHARACTERISTICS 6 17.

2 HYDRONIC GROUP (Optional) 31. 7. FUNCTIONS 7 18. ELECTRICAL DATA 57. 8. VERSIONS 7 19. FULL LOAD SOUND LEVEL 60. 9. Technical SPECIFICATIONS 8 20. DIMENSIONAL DRAWINGS 66. 10. ACCESSORIES 10. Please fill out the requested information Please fill out the requested information This company participates in the Eurovent Certifi cation Programme. Company quality system The products are listed in the Directory of certifi ed products. certified to UNI EN ISO 9001. Eurovent certifi cation applied to units with cooling capacity up to 1500 kW and environmental certification for air cooled water chillers and water cooled liquid chillers. UNI EN ISO 14001. Waiver of liability This publication represents a preliminary document, and is the All work must be performed, components selected and materi- sole property of Climaveneta.

3 Any reproduction or disclosure of als used professionally and in complete accordance with the such is strictly prohibited without the written authorisation of Cli- legislation in force in material in the country concerned, and maveneta. considering the operating conditions and intended uses of the This document has been prepared with maximum care and system, by qualified personnel. attention paid to the content shown. Nonetheless, Climaveneta The data contained in this publication may be changed without waives all liability deriving from the use of such document. prior notice. Read this document carefully. NX_0152P_0812P_201205_EN HFC 410A. 2. NX. 1. CLIMAVENETA, THE MOST PROFITABLE WAY. TO IMPROVE THE LEED CERTIFICATION OF. YOUR BUILDING. Climaveneta is a Green Building Council Italy member and actively supports the diffusion of LEED practice all around the world.

4 Climaveneta High and Premium efficiency products and sys- tems are designed with special care to LEED protocol compli- ance and can help to achieve and improve the LEED certifica- tion of the building. In particular Climaveneta High and Premium efficiency products and systems meet the LEED prerequisites for Energy & Atmos- phere (EA) and Indoor Environmental Quality (EQ) and can help to gather LEED points with regard to following areas: ENERGY & ATMOSPHERE (EA). 24 HVAC related LEED NC (New Construction and major Reno- vation Projects) points possible: EA Prerequisite 2 Minimum Energy Performance EA Prerequisite 3 Fundamental refrigerant Management EA Credit 1 Optimize Energy Performance - 1 to 19 Points EA Credit 4 - Enhanced refrigerant Management - 1 to 2. Points EA Credit 5 Measurement & Verification 1 to 3 Points INDOOR ENVIRONMENTAL QUALITY (EQ).

5 6 HVAC related LEED points possible EQ Prerequisite 1 Minimum Indoor Air Quality Performance EQ Credit 1 Outdoor Air Delivery Monitoring 1 Point EQ Credit 2 Increased Ventilation 1 Point EQ Credit 5 Indoor Chemical & Pollutant Source Control 1. Point EQ Credit Controllability of Systems: Thermal Comfort . 1 Point EQ Credit Thermal Comfort: Design 1 Point EQ Credit Thermal Comfort: Verification 1 Point There are already several buildings LEED certified also thanks to Climaveneta HVAC systems. For more information, browse the project list at NX_0152P_0812P_201205_EN HFC 410A. 3. NX. 2. DESCRIPTION OF THE UNIT 3. MODELS AND VERSIONS. NX /K: NEW COMPACT LIQUID CHILLERS Compact versions with standard efficiency NX is the new Climaveneta liquid chiller, available in the new K. version, combining the two main features of this unit: efficiency NX/K: liquid chiller with standard efficiency, compact and compactness.

6 Version NX in fact achieves excellent levels of energy efficiency while at NX/LN-K: liquid chiller with standard efficiency, compact the same time occupying less area, making this unit the best and low noise version solution in all installations where there is limited space avail- NX/SL-K: liquid chiller with standard efficiency, compact able. and Super low noise version Along with its compact dimensions, NX also comes in three ver- NX/D /K: liquid chiller with standard efficiency, compact sions with different sound emission ratings, so as to comply with version, including desuperheater for partial the strictest installation requirements. recovery of the heat of condensation The LN and SL versions reduce noise levels by up to 10dB(A) NX/D /LN-K: liquid chiller with standard efficiency, compact compared to the most compact version, making the NX the ide- and low noise version, including desuper- al solution for satisfying the most demanding installation needs heater for partial recovery of the heat of con- not only in terms of efficiency and compactness, but also low densation noise.

7 NX/D /SL-K: liquid chiller with standard efficiency, compact This ensures maximum installation flexibility, an essential and Super low noise version, including desu- requirement when operating in restricted spaces or when perheater for partial recovery of the heat of replacing or upgrading existing systems. condensation NX/CA: NEW HIGH EFFICIENCY LIQUID CHILLERS WITH Compact versions with high efficiency ENERGY CLASS A. When energy efficiency is a fundamental prerequisite, the Cli- NX /CA: liquid chiller with high efficiency, compact ver- maveneta NX/CA represents the best solution, ensuring the sion highest efficiency in its category, with Eurovent class A EER val- NX /LN-CA: liquid chiller with high efficiency, compact and ues, calculated based on the restrictive European standard low noise version EN14511.

8 NX /SL-CA: liquid chiller with high efficiency, compact and NX/CA also features three different versions as regards sound Super low noise version emissions. NX /D /CA: liquid chiller with high efficiency, compact ver- In addition to the standard version, two further versions can be sion, including desuperheater for partial selected, LN-CA and SL-CA, which reduce noise by up to recovery of the heat of condensation 10dB(A) while maintaining the same energy efficiency class. NX /D /LN-CA: liquid chiller with high efficiency, compact and Indeed the main new feature that distinguishes the Climaveneta low noise version, including desuperheater for NX/CA units from other products available on the market is the partial recovery of the heat of condensation availability of a complete selection of versions with different NX /D /SL-CA: liquid chiller with high efficiency, compact and sound emissions however without affecting the energy efficien- Super low noise version, including desuper- cy class, rather maintaining exceptional efficiency, all rated heater for partial recovery of the heat of con- Eurovent class A.

9 Densation NX_0152P_0812P_201205_EN HFC 410A. 4. NX. 4. HOW TO SELECT THE NX. NX /K NX /KA. Compact standard efficiency version Class A high efficiency version Standard version NX /K NX /CA. NX /LN-K NX /LN-CA. Compared to the standard version Compared to the standard version Low noise version (LN). - retains the same dimensions - retains Class A energy efficiency - noise reduction of up to 6dB(A) - noise reduction of up to 6dB(A). NX /SL-K NX /SL-CA. Compared to the low noise version (LN-K) Compared to the low noise version (LN). Super low noise version (SL) - retains the same dimensions (where possible) - retains Class A energy efficiency - further noise reduction of 4 to 6dB(A) - further noise reduction of 4 to 5dB(A). compared to the low noise version (LN-K) compared to the low noise version (LN-K). NX /D /SL-CA 0812P.

10 P - braze-welded plate Heat exchanger - based on the cooling capacity Size /K - compact standard efficiency /LN-K - compact std efficiency, low noise Version /SL-K - compact std efficiency, super low noise /CA - Class A. /LN-CA - Class A, low noise Function empty - no function /SL-CA - Class A, super low noise /D - with partial heat recovery NX - liquid chiller Name UNIT STRUCTURE. Please refer to the following table for more details about the type of structure adopted on each size and version. Model Size Horizontal V-shaped coil --- --- --- --- --- --- --- 0412P 0462P 0512P 0562P 0612P 0712P 0712P. module Longitudinal V-shaped coil 0152P 0182P 0202P 0252P 0262P 0302P 0352P 0402P 0452P 0502P 0552P 0602P 0702P 0802P. module Version Cooling capacity kW. K 39 44 52 59 65 78 88 102 115 127 144 166 189 207. LN-K 39 44 52 59 66 75 90 99 112 125 140 163 179 194.