Transcription of TECHNICAL CALCULATION AND ESTIMATOR'S MAN-HOUR …
1 TECHNICAL CALCULATIONAND ESTIMATOR'S MAN-HOUR MANUALM arko Buli Marko Buli TECHNICAL CALCULATION AND ESTIMATOR'SMAN-HOUR MANUALERECTION OF PROCESS OR CHEMICAL ABOVE TANKS CYLINDRICAL AND AND FLAME ABOVE GROUNDESTIMATE POINTS FOR BUILD-IN CALCULATIONMANNER OF DATAS HOURS FOR OVERHAULS INPETROCHEMICAL AND MAN HOURS FOR PIPING ANDSTEEL STRUCTURE WORKS IN CALL FORTENDERS OF TECHNIP , 2003.(Completed edition)All right book, or parts thereof, may not be reproducedin any form without permission of the you for showing interest in buying our book TECHNICAL CALCULATION AND ESTIMATOR'S MANHOURS MANUALYou can buy the electronic version of the Manual containing all the figurest and other related data at the following MANUAL (239 pages)US$ 600US$ 10002.
2 EACH CHAPTERIPIPING ABOVE GROUND - 36 pages + 20*US$ 180US$ 300 IIPIPELINES - 7 pages + 20*US$ 75US$ 120 IIISTEEL STRUCTURES - 7 pages + 20*US$ 80US$ 130 IVPROCESS EQUIPMENT - 10 pages + 20*US$ 70US$ 110 VSTORAGE TANKS - CYLINDRICAL & SPHERICAL - 11 pages + 20*US$ 80US$ 130 VIWELDING AND FLAME CUTTING - 18 pages + 20*US$ 75US$ 120 VIICORROSION PROTECTION - 3 pages + 20*US$ 35US$ 55 VIIITHERMAL INSULATION - 3 pages + 20*US$ 35US$ 55 IXESTIMATES - 11 pages + 20*US$ 100US$ 165 XPIPING ABOVE GROUND - ESTIMATE POINTSFOR BUILD-IN ITEMS - 76 pages + 20*US$ 130US$ 215 XIWEIGHT FACTORS - 7 pagesUS$ 15US$ 25 XIITECHNICAL CALCULATIONMANNER OF DATA COMPILING - 4 pagesUS$ 6US$ 10 XIIIMANHOURS FOR OVERHAULS INPETROCHEMICAL PLANTS - 16 pages + 20*US$ 80US$ 130 XIVFACTORS AND MANHOURS FOR PIPING ANDSTEEL STRUCTURE WORKS IN CALL FOR TENDERSOF TECHNIP COMPANY - 3 pages + 20*US$ 60US$ 100 NOTE: +20* = THE FIRST 13 PAGES OF THE MANUAL AND 7 PAGES OF THE PERSONALISED ANALOGUE VERSION OF THE MANUAL COULD BE ORDERED AS , email us your full address and indicate the purchase option you have decided for.
3 Onic manual immediately. As soon as your payment is received we shall send you the password that will enable you to open and use the congratulate you on your choice and thank you for buying our electronic entityWe shall send you the electrPREFACEAll 40 years of my working life, I spent on erection of different process plants most of which were oil industry projects in the country and abroad, in Europe and North Africa. Since 1978 with occasional interruptions because of simultaneous involvement in several different projects, I worked mostly on TECHNICAL calculations. I have made hundreds and hundreds calculations based on all kinds of tenders and erection of mechanical equipment.
4 The tenders were written in various foreign languages and alphabet, even in Cyrillic. I am fully aware of the problems an estimator encounters when working on TECHNICAL calculations for specific technologies. Very often tenders were not complete and not detailed enough, and the time required for a good TECHNICAL CALCULATION is getting every day shorter. It is not easy to present exact TECHNICAL figures and quantities for the equipment or operations not fully defined, hard to comprehend, or even unknown to the estimator. TECHNICAL terms and expressions written in different languages and dialects are often incorrect and specific for individual branches.
5 Enormous experience is needed, an ability to assess and estimate, and even the courage to write down the TECHNICAL quantities and was the reason for collecting various TECHNICAL bibliography, standards, catalogues, man hours and rates from the European and USA countries. I have made the analyses, comparisons, simulations, new measures, and manhour tables. A great deal of that was verified in practice during the plant erection. I surveyed the results and analyses of as-built designs. On many occasions, I sought a compromise between different opinions and standpoints. Too many things collected on too many places.
6 Finally, I decided to write this manual for discriminative estimators. It is important to understand that there are no identical projects or jobs in this business, that each project is specific and that no automatism or copying is possible. Approach to any job should be serious and professional and a TECHNICAL CALCULATION should be made with the assistance of this Manual. Many people try to include the man hours from the tables into the computer systems, which I oppose. Those are the people, which instead of using a computer, a computer uses them. An estimator himself must choose the values and define the man hours taking into account all the elements that might have any influence on them.
7 Only when the relevant man hours are estimated and selected, a computer can be used. A saying Switch on your brain before switching on the computer should be most complex work in developing these man hours was the work on the man hours for piping above ground. A basis I used was a system for estimating the value of erection works of a German Company LINDE, which I completed and modified. Generally, for elaboration of the man hours for erection/installation of process equipment, I used the English man hours of the Oil and Chemical Plant Constructors Association, but I used other sources as source or the author was noted for other tables and if I modified them, I provided the modification basis.
8 Where there are no such notes, I am the only complete edition of this manual in the Croatian language and its sections were published in 1997 and 2000. This is why I have not given a unified percentage of the production efficiency but each chapter has its Buli Zagreb Croatia, 2003 & I. PIPING ABOVE OPERATING TIME STANDARD FORTABLES FACTOR OF BASIC ASSEMBLY1. PIPES (ANSI B. ).. - INSTALLATION ON PROCESS - INSTALLATION ON PIPE RACK OR SLEEPER (ANSI B. ).. - CONCENTRIC AND PIPES (DIN 2448/2458).. - INSTALLATION IN PROCESS - INSTALLATION ON PIPE RACK OR SLEEPER TRACING (ANSI & DIN).
9 AND CONTROL DISTRIBUTORS AND CONDENSATE COLLECTORSFABRICATED FROM PIPES AND DISTRIBUTORS AND CONDENSATE COLLECTORS FABRICATEDFROM READY MADE DISTRIBUTORS FOR 4 FITTINGS (DIN).. - CONCENTRIC AND - JOINT + STUB SMALL , SOCKOLETS, NIPOLETS, COUPLINGS FOR WITH SOCKET WITH FLANGED WITH WELDING FOR THREADED FOR TENDER ESTIMATE FOR INSTALLATION OF ASSESSMENT FOR QUICK IN PROCESS (CARBON STEEL - NOT INSULATED) - MEAN (CARBON STEEL) - MEAN - MEAN DIAMETER - Manner of FOR INSTALLATION OF POLYETHYLENE FOR ERECTION OF PVC & FRP STEEL PIPING CEMENT LINED MADE OF STEEL AND GREY FOR PIPING BASED ON INCH-DIAMETER (ID).
10 FOR UNITS OF OPERATION - BASED ON INCH-DIAMETER (ID).. FOR PIPING HOURS FOR WELDING OF CALCULATION - MAN HOURS FOR PIPING MODIFICATION AT OF PIPING ABOVE - GROUNDP refabrication and installation II. OF IN UNDER ROADS AND OUT OF PIPELINE OF CLEANING UP PIPELINE SPECIAL AND FINISHING STEEL STRUCTURE BASIC MAN HOURS - THE OF OF STRUCTURE TO ERECTION OF ANCHOR OF LOST OF WIRE ROPE OF FROM ERECTION OF MISCELLANEOUS STEEL MANHOUR CORRECTION STEEL STRUCTURES IN OIL REFINERIES AND PETROCHEMICAL STRUCTURE (to 30 kg/m).