Example: biology

Technical Data for ADL Power Supplies - adl …

Technical data for ADL Power SuppliesSeiteGS 05 - GS 302GS 60 - GS 1504 GSW 100 - GSW 3005GX 50 - GX 1509HX 150 - HX 30011GP and GPW- Power Supplies for Melec Pulse Generators1316171819202122D300 Cathode Clamp Diode23 Maris Remote Control RC 424 ADLP ower Supplies for Ion Sources - Cathode GCPower Supplies for Ion Sources - Magnet GMPower Supplies for Plasma Sources - GDADL-Pulse Generator RD 300 Power Supplies for Ion Sources - Accelerator and Beam GG 03, , GG12, GG Supplies for Ion Sources - Neutralizer GIP 10 and GIP Supplies for Ion Sources - Discharge GDIADL Technical DataVersion 09-20091 Table 1GS 05/800GS 10/800GS 15/800GS 20/800GS 30/800 Nominal power0,5kW1kW1,5kW2kW3kWOutput voltage800V800V800V800V800 VOutput current0,9A1,7A3A3,5A5,3 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption0,6kVA1,2kVA1,8kVA2,4kVA3,6kV AFusing6A6A6A (10A)6A (10A)10 ACoolingSizeWeight11kg12kg230V, +5/-10 %, 50/60Hz, (Option: 200V, L1, L2, PE)3 x 400V, +5/-10%, 50/60Hz,(Option: 3 x 200V, only GS 15, GS 20), PEGS 05 - GS 30 Current, voltage or Power controlledForced air, maximum ambiente temperature 40 CQuenching time: 6 s up to 3ms, automaticallyDelay time: 6

Technical Data for ADL Power Supplies Seite GS 05 - GS 30 2 GS 60 - GS 150 4 GSW 100 - GSW 300 5 GX 50 - GX 150 9 HX 150 - HX 300 11 GP and GPW-Power Supplies for Melec Pulse Generators 13

Tags:

  Supplies, Data, Technical, Power, Technical data for adl power supplies

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Technical Data for ADL Power Supplies - adl …

1 Technical data for ADL Power SuppliesSeiteGS 05 - GS 302GS 60 - GS 1504 GSW 100 - GSW 3005GX 50 - GX 1509HX 150 - HX 30011GP and GPW- Power Supplies for Melec Pulse Generators1316171819202122D300 Cathode Clamp Diode23 Maris Remote Control RC 424 ADLP ower Supplies for Ion Sources - Cathode GCPower Supplies for Ion Sources - Magnet GMPower Supplies for Plasma Sources - GDADL-Pulse Generator RD 300 Power Supplies for Ion Sources - Accelerator and Beam GG 03, , GG12, GG Supplies for Ion Sources - Neutralizer GIP 10 and GIP Supplies for Ion Sources - Discharge GDIADL Technical DataVersion 09-20091 Table 1GS 05/800GS 10/800GS 15/800GS 20/800GS 30/800 Nominal power0,5kW1kW1,5kW2kW3kWOutput voltage800V800V800V800V800 VOutput current0,9A1,7A3A3,5A5,3 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption0,6kVA1,2kVA1,8kVA2,4kVA3,6kV AFusing6A6A6A (10A)6A (10A)10 ACoolingSizeWeight11kg12kg230V, +5/-10 %, 50/60Hz, (Option: 200V, L1, L2, PE)3 x 400V, +5/-10%, 50/60Hz,(Option: 3 x 200V, only GS 15, GS 20), PEGS 05 - GS 30 Current, voltage or Power controlledForced air, maximum ambiente temperature 40 CQuenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca.

2 10ms, automaticallyManual via front panel or external via A/D interface AS 4, AS 4 F or Profibus0 ..100 % of nominal current, voltage or Power +/- 1 % of nominal value for current, voltage or Power 19 slide-in, 3HU (132,5mm), 560mm deep3 - digit display for current, voltage and powerLpA < 70db (A)ADL Technical DataVersion 09-20092 Table 2GS 05/1000GS 10/1000GS 15/1000GS 20/1000GS 30/1000GS 12/2000 Nominal power0,5kW1kW1,5kW2kW3kW1,2kWOutput voltage1000V1000V1000V1000V1000V2000 VOutput current0,7A1,4A2,4A2,8A4,2A1 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption0,6kVA1,2kVA1,8kVA2,4kVA3,6kV A1,4kVAFusing6A6A6A (10A)6A (10A)10A6 ACoolingSizeWeight12kg11kg3 - digit display for current, voltage and power230V, +5/-10%, 50/60Hz, (Option: 200V, L1, L2, PE)3 x 400V, +5/-10%, 50/60Hz,(Option.)

3 3 x 200V, nur GS 15, GS 20), PE 19 slide-in, 3HU (132,5mm), 560mm deepLpA < 70db (A)Forced air, maximum ambiente temperature 40 C0 ..100 % of nominal current, voltage or Power +/- 1 % of nominal value for current, voltage or powerCurrent, voltage or Power controlledManual via front panel or external via A/D interface AS 4, AS 4 F or ProfibusQuenching time: 6 s up to 3ms, automaticallyDelay Time: 6 s up ca. 10ms, automaticallyADL Technical DataVersion 09-20093 Table 1GS 60/800GS 80/800GS 100/800GS 120/800GS 150/800 Nominal power6kW8kW10kW12kW15kWOutput voltage800V800V800V800V800 VOutput current10A17A17A20A25 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption6,6kVA9kVA11kVA13,2kVA16,5kVA Fusing16A16A20A25A25 ACoolingSizeWeight27kg29kg29kg29kg31kgMa ins cable4 x 1,5mm 4 x 1,5mm 4 x 2,5mm 4 x 4mm 4 x 4mm 3 x 1,5mm 3 x 2,5mm 3 x 2,5mm 3 x 2,5mm 3 x 4mm 19 slide-in, 3HU (132,5mm) 570mm deepOutput cableRG 213U or+/- 1 % of nominal value for current, voltage or powerQuenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca.

4 10ms, automatically3 x 400V, +5/-10%, 50/60Hz, PEForced air, maximum ambiente temperature 40 C3 - digit display for current, voltage and Power (Option)LpA < 70db (A)GS 60 - GS 150 Current, voltage or Power controlled0 ..100 % of nominal current, voltage or powerManual via front panel or external via A/D interface AS 4, AS 4 F or ProfibusADL Technical DataVersion 09-20094 Table 1 GSW 100/500 GSW 100/800 GSW 150/400 GSW 150/500 GSW 150/600 GSW 150/750 Nominal power10kW10kW15kW15kW15kW15kWOutput voltage500V800V400V500V600V750 VOutput current40A20A80A60A50A38 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption11kVA11kVA16,5kVA16,5kVA16,5k VA16,5kVAFusing3 x 20A3 x 20A3 x 25A3 x 25A3 x 25A3 x 25 ACoolingWater connectionCooling capability of water500W500W680W680W680W680 WCooling capability of air80W80W80W80W80W80 WSizeWeight42kg42kg44kg44kg44kg44kgMains cable4 x 2,5mm 4 x 2,5mm 4 x 4mm 4 x 4mm 4 x 4mm 4 x 4mm Output cable3 x 10mm 3 x 2.

5 5mm 3 x 25mm 3 x 16mm 3 x 10mm 3 x 10mm Mains connection (X2)DC-connection (X1)GSW 100 - GSW 3000 ..100 % of nominal current, voltage or power19 slide-in, 3HU x 700mm deep (without plug)Harting Han k4/0 Harting Han 2 MODLpA < 70db (A)3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)Quenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca. 10ms, automaticallyCurrent, voltage or Power controlledManual via front panel or external via A/D interface AS 4, AS 4 F or Profibus+/- 1 % of nominal value for current, voltage or powerWater, > 3 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 CSwagelok B-QC 6 ..3 - digit display for current, voltage and Power (Option)ADL Technical DataVersion 09-20095 Table 2 GSW 150/800 GSW 150/1000 GSW 200/500 GSW 200/750 GSW 200/800 GSW 200/900 Nominal power15kW15kW20kW20kW20kW20kWOutput voltage800V1000V500V750V800V900 VOutput current30A25A70A50A40A40 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption16,5kVA16,5kVA22kVA22kVA22kVA 22kVAFusing3 x 25A3 x 25A3 x 35A3 x 35A3 x 35A3 x 35 ACoolingWater connectionCooling capability of water680W680W950W900W900W900 WCooling capability of air80W80W150W100W100W100 WSizeWeight44kg44kg49kg49kg49kg49kgMains cable4 x 4mm 4 x 4mm 4 x 6mm 4 x 6mm 4 x 6mm 4 x 6mm Output cable3 x 6mm 3 x 4mm 3 x 16mm 3 x 10mm 3 x 10mm 3 x 10mm Mains connection (X2)DC-connection (X1)

6 +/- 1 % of nominal value for current, voltage or power3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)Quenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca. 10ms, automatically3 - digit display for current, voltage and Power (Option)LpA < 70db (A)Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus0 ..100 % of nominal current, voltage or power19 slide-in, 3HU x 700mm deep (without plug)Harting Han 2 MODW ater, > 3 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 CSwagelok B-QC 6 ..Current, voltage or Power controlledHarting Han k4/0 ADL Technical DataVersion 09-20096 Table 3 GSW 200/1000 GSW 250/750 GSW 250/800 GSW 250/900 GSW 300/500 GSW 300/800 Nominal power20kW25kW25kW25kW30kW30kWOutput voltage1000V750V800V900V500V800 VOutput current35A60A50A50A70A60 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption22kVA28kVA28kVA28kVA33kVA33kV AFusing3 x 35A3 x 50A3 x 50A3 x 50A3 x 63A3 x 63 ACoolingWater connectionCooling capability of water900W1100W1100W1100W1300W1300 WCooling capability of air100W110W110W110W150W150 WSizeWeight49kg51kg51kg51kg53kg53kgMains cable4 x 6mm 4 x 10mm 4 x 10mm 4 x 10mm 4 x 10mm 4 x 10mm Output cable3 x 6mm 3 x 16mm 3 x 10mm 3 x 10mm 3 x 16mm 3 x 16mm Mains connection (X2)DC-connection (X1)

7 Harting Han k4/00 ..100 % of nominal current, voltage or powerManual via front panel or external via A/D interface AS 4, AS 4 F or Profibus3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)Swagelok B-QC 6 ..19 slide-in, 3HU x 700mm deep (without plug)Harting Han 2 MODC urrent, voltage or Power controlled+/- 1 % of nominal value for current, voltage or powerQuenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca. 10ms, automatically3 - digit display for current, voltage and Power (Option)Water, > 3 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 CLpA < 70db (A)ADL Technical DataVersion 09-20097 Table 4 GSW 300/1000 Nominal power30kWOutput voltage1000 VOutput current50 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption33kVAFusing3 x 63 ACoolingWater connectionCooling capability of water1300 WCooling capability of air150 WSizeWeight53kgMains cable4 x 10mm Output cable3 x 10mm Mains connection (X2)DC-connection (X1)Harting Han k4/0 Harting Han 2 MODQ uenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca.

8 10ms, automatically3 x 400V, +/-10%, 50/60Hz, PE(Option: 3 x 440V oder 3 x 480V)Water, > 3 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 CSwagelok B-QC 6 ..Manual via front panel or external via A/D interface AS 4, AS 4 F or Profibus0 ..100 % of nominal current, voltage or Power +/- 1 % of nominal value for current, voltage or power19 slide-in, 3HU x 700mm deep (without plug)Current, voltage or Power controlled3 - digit display for current, voltage and Power (Option)LpA < 70db (A)ADL Technical DataVersion 09-20098 Table 1GX 50/800GX 60/800GX 80/800GX 80/1000GX100/400GX100/600 Nominal power5kW6kW8kW8kW10kW10kWOutput voltage800V800V800V1000V400V600 VOutput current14A15A20A16A38A30 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption6kVA6,6kVA9kVA9kVA11kVA11kVAF using3 x 16A3 x 16A3 x 20A3 x 20A3 x 20A3 x 20 ACoolingWater connectionCooling capability of water300W300W400W400W500W500 WCooling capability of air45W45W50W50W50W50 WSizeWeight21kg21kg23kg23kg23kg23kgMains cable4 x 1,5mm 4 x 1,5mm 4 x 2,5mm 4 x 2,5mm 4 x 2,5mm 4 x 2,5mm Output cable3 x 1,5mm 3 x 1,5mm 3 x 2,5mm 3 x 2,5mm 3 x 6mm 3 x 6mm Mains connection (X2)DC-connection (X1)LpA < 70db (A)3 x 400V, +/-10%, 50/60Hz 19 slide-in, 3HU (130mm)

9 520mm deep (without plug), 590mm (with plug).Swagelok B-QC 6 ..0 ..100 % of nominal current, voltage or Power +/- 1 % of nominal value for current, voltage or powerQuenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca. 10ms, automatically3 - digit display for current, voltage and Power (Option)GX 60 - GX 150 Current, voltage or Power controlledHarting Han-Modular CompactWater, > 1,5 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 CManual via front panel or external via A/D interface AS 4, AS 4 F or ProfibusHarting Han-Modular CompactADL Technical DataVersion 09-20099 Table 2GX 100/800GX 100/1000GX120/800GX 150/800GX 150/1000 Nominal power10kW10kW12kW15kW15kWOutput voltage800V1000V800V800V1000 VOutput current25A20A30A38A30 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption11kVA11kVA13,2kVA16,5kVA16,5k VAFusing3 x 20A3 x 20A3,25A3 x 25A3 x 25 ACoolingWater connectionCooling capability of water500W500W600W750W750 WCooling capability of air50W50W60W60W60 WSizeWeight23kg23kg23kg25kg25kgMains cable4 x 2,5mm 4 x 2.

10 5mm 4 x 4mm 4 x 4mm 4 x 4mm Output cable3 x 4mm 3 x 4mm 3 x 6mm 3 x 6mm 3 x 6mm Mains connection (X2)DC-connection (X1)Swagelok B-QC 6 ..3 - digit display for current, voltage and Power (Option)Quenching time: 6 s up to 3ms, automaticallyDelay time: 6 s up ca. 10ms, automaticallyLpA < 70db (A)3 x 400V, +/-10%, 50/60 HzHarting Han-Modular CompactHarting Han-Modular Compact+/- 1 % of nominal value for current, voltage or powerManual via front panel or external via A/D interface AS 4, AS 4 F or Profibus 19 slide-in, 3HU (130mm) 520mm deep (without plug), 590mm (with plug).Water, > 1,5 L/Min, 2 to 8 Bar, < 40 CForced air, maximum ambiente temperature 40 C0 ..100 % of nominal current, voltage or powerCurrent, voltage or Power controlledADL Technical DataVersion 09-200910 Table 1HX150/400HX150/500HX150/600HX150/800HX1 50/1000HX200/500 Nominal power15kW15kW15kW15kW15kW20kWOutput voltage400V500V600V800V1000V500 VOutput current80A60A50A30A25A70 AControlModes of operationSet pointOutput accuracyArc suppression IndicationsNoise emissionMains connectionPower consumption16,5kVA16,5kVA16,5kVA16,5kVA1 6,5kVA22kVAFusing3 x 25A3 x 25A3 x 25A3 x 25A3 x 25A3 x 35 ACoolingWater connectionCooling capability of water680W680W680W680W680W950 WCooling capability of air80W80W80W80W80W150 WSizeWeight35kg35kg35kg32kg32kg37kgMains cable4 x 4mm 4 x 4mm 4 x 4mm 4 x 4 mm 4 x 4mm 4 x 6mm Output cable3 x 25mm 3 x 16mm 3 x 10mm 3 x 6mm 3 x 4mm 3 x 16mm Mains connection (X2)DC-connection (X1)