Transcription of TECHNICAL DATA SELF-PRIMING AND MULTISTAGE …
1 JETCOM. SELF-PRIMING CENTRIFUGAL ELECTRIC pumps . SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . TECHNICAL DATA. Operating range: from to m3/h with head up to 54 metres. Liquid quality requirements: clean, free from solid or abrasive contaminants, non-viscous, non-aggressive, uncrystallised and chemically neutral. Liquid temperature range: from 0 C to +35 C for domestic use (EN 60335-2-41). Maximum ambient temperature: +40 C. Maximum operating pressure: 6 bar (600 kPa). Maximum suction depth: 8 metres. Installation: fixed in a horizontal position. Special executions on request: alternative voltages and/or frequencies. Motor protection rating: IP 44. Terminal block protection rating: IP 55. Insulation class: F. Standard input voltage: single phase 220/240 V / 50 Hz three phase 230/400 V - 50 Hz APPLICATIONS. self priming centrifugal pump with excellent suction capacity even in the presence of air bubbles.
2 Suitable for pumping water with low levels of sandy impurities. Especially used in domestic water supply installations. Suitable for small farms and gardening, small scale industrial services and where self priming is necessary. CONSTRUCTIONAL FEATURES OF THE PUMP. Pump body in technocpolymer and motor support in die cast aluminium. Impeller, diffuser, venturi tube and sand guard in technopolymer Stainless steel wear ring. Carbon/ceramic mechanical seal. CONSTRUCTIONAL FEATURES OF THE MOTOR. Asynchronous type, closed, with external air cooling. Rotor mounted on oversized greased-for-life ball bearings, to guarantee low noise and long life. Incorporated thermo-amperometric protection and permanently inserted capacitor in the single phase version. It is recommended to use overload protection for three phase motor protection, in compliance with current legislation. Manufactured pursuant to CEI 2-3 and CEI 61-69 (EN 60335-2-41).
3 DAB pumps reserve the right to make modifications without prior notice 20. JETCOM. SELF-PRIMING CENTRIFUGAL ELECTRIC pumps . SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . MATERIALS. N PARTS * MATERIALS. 1 4 28 7. 1 PUMP BODY TECHNOPOLYMER A. 4 IMPELLER TECHNOPOLYMER A. AISI 416 STAINLESS STEEL. 7 SHAFT WITH ROTOR. X12 CrS13 - UNI 6900/71. 16 MECHANICAL SEAL CARBON/CERAMIC. 28 OR GASKET NBR RUBBER. AISI 304 STAINLESS STEEL 160 16 3. 36 SEAL HOLDER COVER. X5 CRNi 1810 - UNI 6900/71. 160 VENTURI DIFFUSER NOZZEL GROUP TECHNOPOLYMER A. * In contact with liquid self priming CAPACITY. 10 H 10 H. (ft) (ft). 30 30. 9 9. 8 8. 25 25. 7 7. 20 20. 6 6. Hs (m) Suction head Hs (m) Suction head 5 5. 15 15. 4 4. 3 10 3 10. 2 2. 5 5. G1. DN 25 1 1. 0 0 0 0. 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100. t (sec) self priming timing t (sec) self priming timing DAB pumps reserve the right to make modifications without prior notice 21.
4 JETCOM. SELF-PRIMING CENTRIFUGAL ELECTRIC pumps . SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . PERFORMANCE RANGE. The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. GRAPHIC SELECTION TABLE. 5 10 15 30 50 Q US gpm 5 10 15 30 50 Q IMP gpm H H. kPa m H. JET GARDENJET AQUAJET ft 700 70 JETINOX GARDEN INOX AQUAJET INOX. JETCOM GARDEN COM. 600 60 62 - 82 - 102 - 112 200. JET GARDENJET AQUAJET. JETINOX GARDEN INOX AQUAJET INOX. 500 JETCOM GARDEN COM. 50 92 - 132. 150. 400 40. 300 30 100. JET 151 JET 200. JET 251 JET 300. 200 20. 50. 100 10. 1 2 3 4 5 6 7 8 9 10 15 Q m3/h 1 2 3 Q l/s 20 30 50 100 150 200 Q l/min JETCOM SELECTION TABLE. Q=m3/h 0 MODEL. Q=l/min 0 10 20 30 40 50 60 70 80. JETCOM 62 M 42 35 13. JETCOM 82 M 47 40 34 30 20. JETCOM 102 M 47 41 H. JETCOM 102 T (m). 47 41 JETCOM 92 M 31 26 24 JETCOM 132 M 40 35 30 JETCOM 132 T 40 35 30 DAB pumps reserve the right to make modifications without prior notice 22.
5 JETCOM 62- SELF-PRIMING CENTRIFUGAL ELECTRIC pumps FOR DOMESTIC WATER SUPPLY. Liquid temperature range pumped: from 0 C to +35 C - Maximum ambient temperature: +40 C. A. 0 2 4 6 8 10 12 Q US gpm C 0 2 4 6 8 10 Q IMP gpm SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . P H H. kPa m ft DNM 400 40. 120. DNA. 300 30 100. JETCOM 62. 80. H. H2. 200 20. Hs 9 60. 8. 7 6 5 40. 4. F 100 10 3. 2. E I 20. G. 0 0 0. B 0 0,5 1 1,5 2 2,5 3 Q m3/h 0 0,2 0,4 0,6 0,8 Q l/s 0 10 20 30 40 50 Q l/min The performance curves are based on the kinematic viscosity values =. 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA. MODEL POWER SUPPLY P1 P2 NOMINAL In CAPACITOR. 50 Hz MAX kW kW HP A F Vc JETCOM 62 M 1x220-240 V ~ 450. PACK DIMENSIONS GROSS. DNA DNM VOLUME. MODEL A B C E F G H H1 H2 I L WEIGHT. GAS GAS L/A L/B H (mc) Kg JETCOM 62 406 170 122 208 14 111 198 144 9 1 1 470 240 240 JETCOM 82- SELF-PRIMING CENTRIFUGAL ELECTRIC pumps FOR DOMESTIC WATER SUPPLY.
6 Liquid temperature range pumped: from 0 C to +35 C - Maximum ambient temperature: +40 C. A. 0 2 4 6 8 10 12 14 16 Q US gpm C 0 2 4 6 8 10 12 14 Q IMP gpm P H. kPa m H. DNM 50 ft DNA. 160. 400 40. 120. 300. JETCOM 82 100. 30. H. H2. 80. 200 20 Hs 9. 60. 8. 7 6. F 100 10. 5. 4. 40. E I 3 2 20. G. 0 0 0. B 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 0,2 0,4 0,6 0,8 1 Q l/s 0 10 20 30 40 50 60 Q l/min The performance curves are based on the kinematic viscosity values =. 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA. MODEL POWER SUPPLY P1 P2 NOMINAL In CAPACITOR. 50 Hz MAX kW kW HP A F Vc JETCOM 82 M 1x220-240 V ~ 450. PACK DIMENSIONS GROSS. DNA DNM VOLUME. MODEL A B C E F G H H1 H2 I L WEIGHT. GAS GAS L/A L/B H (mc) Kg JETCOM 82 406 170 122 208 14 111 198 144 9 1 1 470 240 240 DAB pumps reserve the right to make modifications without prior notice 23.
7 JETCOM 102 - SELF-PRIMING CENTRIFUGAL ELECTRIC pumps FOR DOMESTIC WATER SUPPLY. Liquid temperature range pumped: from 0 C to +35 C - Maximum ambient temperature: +40 C. A. 0 2 4 6 8 10 12 14 16 Q US gpm C 0 2 4 6 8 10 12 14 Q IMP gpm SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . P H. kPa m H. DNM 50 ft DNA. 160. 400 40. JETCOM 102 120. 300 30 100. H. Hs 9. H2. 80. 8. 7. 200 20 6 60. 5 4. 3. 2 40. F 100 10. E I. 20. G. 0 0 0. B 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m3/h 0 0,2 0,4 0,6 0,8 1 Q l/s 0 10 20 30 40 50 60 Q l/min The performance curves are based on the kinematic viscosity values =. 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA. MODEL POWER SUPPLY P1 P2 NOMINAL In CAPACITOR. 50 Hz MAX kW kW HP A F Vc JETCOM 102 M 1x220-240 V ~ 1 16 450. JETCOM 102 T 3x230-400 V ~ 1 . PACK DIMENSIONS GROSS. DNA DNM VOLUME. MODEL A B C E F G H H1 H2 I L WEIGHT.
8 GAS GAS L/A L/B H (mc) Kg JETCOM 102 425 170 122 208 14 111 203 144 9 1 1 470 240 240 JETCOM 92- SELF-PRIMING CENTRIFUGAL ELECTRIC pumps FOR DOMESTIC WATER SUPPLY. Liquid temperature range pumped: from 0 C to +35 C - Maximum ambient temperature: +40 C. A. 0 2 4 6 8 10 12 14 16 18 20 22 24 Q US gpm C 0 2 4 6 8 10 12 14 16 18 20 Q IMP gpm P H. H. kPa m DNM ft 140. DNA. 400 40. 120. 300 30 100. JETCOM 92. H. 80. H2. 200 20. 60. Hs 9. 8 40. 7. F 100 10 6 5. E I 4. 3 20. 2. G. 0 0 0. B 0 1 2 3 4 5 Q m3/h 0 0,2 0,4 0,6 0,8 1 1,2 1,4 Q l/s 0 10 20 30 40 50 60 70 80 90 Q l/min The performance curves are based on the kinematic viscosity values =. 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA. MODEL POWER SUPPLY P1 P2 NOMINAL In CAPACITOR. 50 Hz MAX kW kW HP A F Vc JETCOM 92 M 1x220-240 V ~ 1 14 450. PACK DIMENSIONS GROSS. DNA DNM VOLUME. MODEL A B C E F G H H1 H2 I L WEIGHT.
9 GAS GAS L/A L/B H (mc) Kg JETCOM 92 425 170 122 208 14 111 203 144 9 1 1 470 240 240 DAB pumps reserve the right to make modifications without prior notice 24. JETCOM 132 - SELF-PRIMING CENTRIFUGAL ELECTRIC pumps FOR DOMESTIC WATER SUPPLY. Liquid temperature range pumped: from 0 C to +35 C - Maximum ambient temperature: +40 C. A. 0 2 4 6 8 10 12 14 16 18 20 22 24 Q US gpm C. SELF-PRIMING AND MULTISTAGE CENTRIFUGAL pumps . 0 2 4 6 8 10 12 14 16 18 20 Q IMP gpm P H. H. kPa m DNM ft 140. 400. DNA. 40. JETCOM 132 120. 300 30 100. H. 80. H2. 200 20. 60. Hs 9. 8 7 40. 6. F 100 10 5. E I 4. 3 20. G 2. 0 0 0. B 0 1 2 3 4 5 Q m3/h 0 0,2 0,4 0,6 0,8 1 1,2 1,4 Q l/s 0 10 20 30 40 50 60 70 80 90 Q l/min The performance curves are based on the kinematic viscosity values =. 1 mm2/s and density equivalent to 1000 kg/m3. Curve tolerance according to ISO 9906. ELECTRICAL DATA. MODEL POWER SUPPLY P1 P2 NOMINAL In CAPACITOR.
10 50 Hz MAX kW kW HP A F Vc JETCOM 132 M 1x220-240 V ~ 1 25 450. JETCOM 132 T 3x230-400 V ~ 1 . PACK DIMENSIONS GROSS. DNA DNM VOLUME. MODEL A B C E F G H H1 H2 I L WEIGHT. GAS GAS L/A L/B H (mc) Kg JETCOM 132 M 425 170 122 208 14 111 203 144 9 1 1 470 240 240 JETCOM 132 T 441 170 122 208 14 111 203 144 9 1 1 470 240 240 DAB pumps reserve the right to make modifications without prior notice 25.