CR. nic so pe Ma Thin section soundproofing membrane to combat the noise of footsteps transmitted through floor slabs, applied before laying ceramic, stone, resilient and multi-layered parquet floors WHERE TO USE M. ay be applied immediately before laying the floor Under-floor soundproofing system applied in a thin coverings. layer to counteract the transmission of noise through floors caused by footsteps. L. ow thickness. Mapesonic CR has been specifically developed W. ith very low emission of volatile organic compounds for application in existing buildings to improve (EMICODE EC1 Plus). soundproofing without removing the floors and screeds. M. ay be applied on heated floors. It is particularly suitable, therefore, for all buildings (residential units, hotels, offices, rest-homes, schools, C. ertified according to current standards. etc.) under renovation. RECOMMENDATIONS. Some application examples O. nly apply on horizontal internal surfaces.

Apply the skirting around the room without coming into direct contact with the floor. Seal the space between the skirting and the floor with a suitable flexible sealant.

Tags:

  Data, Technical, Value, Technical data, Typical, Mapei, Typical values

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of TECHNICAL DATA (typical values) - Mapei

1 CR. nic so pe Ma Thin section soundproofing membrane to combat the noise of footsteps transmitted through floor slabs, applied before laying ceramic, stone, resilient and multi-layered parquet floors WHERE TO USE M. ay be applied immediately before laying the floor Under-floor soundproofing system applied in a thin coverings. layer to counteract the transmission of noise through floors caused by footsteps. L. ow thickness. Mapesonic CR has been specifically developed W. ith very low emission of volatile organic compounds for application in existing buildings to improve (EMICODE EC1 Plus). soundproofing without removing the floors and screeds. M. ay be applied on heated floors. It is particularly suitable, therefore, for all buildings (residential units, hotels, offices, rest-homes, schools, C. ertified according to current standards. etc.) under renovation. RECOMMENDATIONS. Some application examples O. nly apply on horizontal internal surfaces.

2 Mapesonic CR may be used: D. o not apply in areas subject to heavy traffic. under resilient floor coverings (PVC, rubber, linoleum);. under multi-layered parquet; D. o not apply under lightweight or shiny resilient floor coverings or under cushion-floor. on cement-based substrates;. Apply Mapesonic Strip around the perimeter to on old ceramic and stone floors. avoid the formation of acoustic bridges. TECHNICAL CHARACTERISTICS D. o not expose the material to direct sunlight. Mapesonic CR is manufactured using recomposed cork and rubber bound together with high-quality W. hen applying the product to cementitious substrates polyurethane composite. ensure they are completely cured. ADVANTAGES D. o not apply on floating floors or floors to be polished Efficient reduction of noise from footsteps. in situ. Easy and quick installation. M. ake sure the product is applied on solid substrates. ic CR. eson TECHNICAL data ( typical values).

3 P Ma PRODUCT IDENTITY. Thickness: 2 mm 4 mm Net weight (kg): Length (m): 20 10. Width (m): 1 1. Thermal resistance R (m K/W): Material: recomposed cork and rubber bound with polyurethane Colour: brown-black Packaging: rolls EMICODE: EC1 Plus - very low emission Apply Mapesonic Strip adhesive tape around the perimeter of the Elongation at failure EN ISO 1798 (%): 20. room Tensile strength EN ISO 1798 (N/mm ): Reduction of noise from footsteps LW in compliance with ISO 10140-3 (former ISO 140-8): 10 dB*. * obtained with Mapesonic CR 2 mm and ceramic tile flooring Do not apply over expansion joints or pipe-work) the substrate must be levelled structural cracks. before laying Mapesonic CR. Do not apply on substrates subject to To even out laying surfaces please refer to continuous rising damp. the catalogues which illustrate the various ranges of Mapei products for the preparation Preparation of the substrate of substrates or contact the Mapei TECHNICAL Mapesonic CR may be applied on all types Services Department.

4 Of cementitious or anhydrite substrates as After suitable long as they are well cured, mechanically APPLICATION PROCEDURE. preparation of the strong, coherent, dry, flat, have no cracks Before laying rolls of soundproofing material, substrate, spread on and are free of dust and other material which and before removing the protective plastic the adhesive to bond the soundproofing could compromise adhesion. backing sheet, apply Mapesonic Strip sheets adhesive tape around the perimeter of Cracks may be repaired with products such the room and around pillars and all other as Eporip, Eporip Turbo or Epojet. abutments. If the moisture content in cementitious The product must be laid in a continuous substrates is higher than the required level, layer, with special care at the corners of the wait sufficient time until it dries or apply a room and at the joints between sections. waterproofing primer such as Eco Prim PU 1K, Primer MF, Triblock P, Primer PU 60, Mapesonic Strip can be applied after laying etc.

5 To form a suitable vapour barrier. Mapesonic CR. Mapesonic CR may be laid on old ceramic On clean, dry surfaces unroll the sheets and stone, floor coverings as long as they of Mapesonic CR in the direction of the are well bonded to the substrate and have longest side of the room. Leave 24 hours to been cleaned to remove traces of grease, oil, acclimatise before cutting them to size. wax, varnish, etc. Roll the sheets up again to half their length, On uneven surfaces and areas where fittings with the remaining part lying on the substrate, Unroll the sheets of pass through (such as electric cables and and spread the adhesive dependant on Mapesonic CR on the surfaces to be soundproofed the characteristics of the substrate on the Apply the skirting around the room without exposed part of the surface. coming into direct contact with the floor. Seal the space between the skirting and the floor Ultrabond Eco V4 SP must be used on with a suitable flexible sealant.)

6 Absorbent substrates, such as screeds and To use the aforementioned Mapei products smoothing and levelling compounds. correctly, please refer to the specific TECHNICAL data sheet for each product Use Ultrabond Eco S955 1K on non- available at our website absorbent substrates, such as ceramic tiles, and for multi-layered parquet. Alternatively, SAFETY INSTRUCTIONS FOR. Ultrabond P902 2K or Ultrabond Eco PREPARATION AND APPLICATION. P909 2K can be used. Mapesonic CR is an article and referring After laying the sheet, massage the surface to the current European regulations (Reg. with a rigid roller or flat trowel, starting from 1906/2007/CE - REACH) does not require the centre and working towards the edge. the preparation of the material safety data Repeat the laying procedure for the second sheet. During use it is recommended to wear part of the roll. gloves and goggles and follow the safety requirements of the workplace.

7 Do not apply too much pressure on the surface while applying Mapesonic CR or PRODUCT FOR PROFESSIONAL USE. until the adhesive used for bonding has WARNING. completely set. While the indications and guidelines Massage the surface contained in this data sheet correspond with a rigid roller or flat 24-48 hours after laying the sheets, the new trowel, starting from to the company's knowledge and wide floor finish may be bonded. the centre and working experience, they must be considered, under towards the edge all circumstances, merely as an indication and We recommend using Kerabond + neat subject to confirmation only after long-term, Isolastic, Ultralite S2 or Keraflex Maxi S1. practical applications. Therefore, anybody to bond ceramic, porcelain and stone not who undertakes to use this product, must sensitive to moisture over Mapesonic CR. ensure beforehand that it is suitable for the intended application and, in all cases, When bonding stone sensitive to moisture the user is to be held responsible for any (class B according to the Mapei classification consequences deriving from its use.)

8 System), use Elastorapid or Granirapid. Please refer to the current version of the If other adhesives are used, please contact TECHNICAL data Sheet, available from our the Mapei TECHNICAL Services Department. website Parquet floors (multi-layered type only) This symbol is used to identify Mapei products which give off a low level of volatile organic may be laid with Ultrabond Eco S955 1K, compounds (VOC) as certified by GEV (Gemein- Ultrabond P902 2K or Ultrabond schaft Emissionskontrollierte Verlegewerkstoffe, Klebstoffe und Bauprodukte ), an international Eco P909 2K. organisation for controlling the level of emissions from products used for floors. When laying resilient floor coatings, we Our Commitment To The Environment recommend applying a cementitious Mapei products assist Project Designers and Contractors create innovative LEED. smoothing and levelling layer of Nivorapid (The Leadership in Energy and Environmental Design) certified projects, in (or Planipatch) + Latex Plus reinforced with compliance with the Green Building Council.

9 Mapenet 150 to distribute concentrated loads. All relevant references Grouting and sealing for the product are available After applying and grouting the new upon request and from floor finish, cut off the excess part of the Mapesonic Strip. Spread the adhesive on the Mapesonic CR. and bond the new floor finish ic CR. eson p Ma (GB) BETA. Grout the surface of the room Once the grout has hardened, trim the perimeter of the Mapesonic Strip to remove the excess Any reproduction of texts, photos and illustrations published here is prohibited and subject to prosecution Apply the skirting around the room without letting Seal the gap between the skirting board and it come into direct contact with the floor the floor with a suitable flexible sealant from the Mapei range 915-3-2016 (GB).. BUILDING THE FUTURE.