Transcription of TECHNICAL DESCRIPTION - Alpine Home Air Products
1 246819-BTG-E-1106 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALER-22 SPLIT-SYSTEM HEAT PUMPS13 SEER R-22 MODELS:E*BD-F018 THRU 060( THRU 5 NOMINAL TONS, 1 PHASE)E*BD-(T,W)036 THRU 060( THRU 5 NOMINAL TONS, 3 PHASE)Due to continuous product improvement, specifications are subject to change without us on the web at for the most up-to-date TECHNICAL 9001 Certified QualityManagement SystemCERTIFICATION APPLIES ONLYWHEN THE COMPLETESYSTEM IS LISTEDWITH TECHNICALGUIDE DESCRIPTIONThe 13 SEER series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or hori-zontal installation to provide a complete system.
2 Electric heat may be installed in air handlers. All units are factory charged to assure easy limited parts limited compressor DURABLE CONSTRUCTION - The outdoor unit is con-structed of pre-painted steel that offers tough protectionagainst corrosion and resists fading when exposed to sun-light. Drain holes are incorporated into the base pan to per-mit free drainage of moisture. QUALITY COILS - The coil is constructed of enhancedcopper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage bya polymer mesh applied between the coil face, and a PVCcoated steel coil guard. PROTECTED COMPRESSOR - The hermetic compressoris internally protected against high pressure and tempera-ture by the simultaneous operation of a high pressure reliefvalve and temperature sensors which stop the compressorif operating temperatures go too high.
3 Both protectorsreset automatically. A discharge line solid core filter drierfurther protects the compressor. Complete System Control These heat pumps utilizethe unique microprocessor defrost control system to pro-vide optimal comfort and to monitor the overall system forreliable operation. The defrost control system continuouslymonitors the space environment to maintain optimum effi-ciency. It initiates defrost only when necessary to furtherreduce heating costs and improve reliability. In the eventimproper operating conditions occur, the control will auto-matically shut the system down to extend the life of theheat pump. Rapid cycling is prevented by use of an inter-nal anti-recycle timer. LOW OPERATING SOUND LEVEL - The compressor ismounted on rubber isolators to reduce operating slow moving condenser fan keeps air turbulence andsound to a low level.
4 EASY ACCESS - Removable panel affords accessibility tothe electrical box. FULLY CHARGED AND FACTORY WIRED - to simplyinstallation and reduce labor costs. Only power supply andcontrol wiring and refrigerant lines must be connected. Allmodels are sweat connect with reusable service valves. Factory tested - to verify system operation and controlfunctioning before shipment. and listed - approved for outdoor in accordance with the Unitary Small Equipment cer-tification program, which is based on ARI Standard 210 Products GroupAll dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon AND ELECTRICAL DATA - 1 PHASEMODELEABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060 SUnit Supply Voltage208-230V, 1 , 60 HzNormal Voltage Range 1187 to 252 Minimum Circuit Overcurrent Device Amps 215252530405060 Min.
5 Overcurrent Device Amps 315202020303540 Compressor Type 4 RecipRecipRecipRecipRecipScrollDScrollDC ompressor AmpsRated Rotor4144607878115150 Crankcase HeaterYesYesYesYesYesNoNoFan Motor Amps Rated Diameter Inches22222222222424 Fan MotorRated HP1/151/41/41/41/41/41/4 Nominal RPM850850850850850850850 Nominal CFM2,0003,2503,4503,5003,5003,4003,500 CoilFace Area Sq. Deep1111122 Fin / Inches22222222221818 Liquid Line Set OD (Field Installed)3/83/83/83/83/83/83/8 Vapor Line Set OD (Field Installed)3/43/47/87/87/87/81-1/8 Unit Charge (Lbs. - Oz.) 57 - 16 - 68 - 78 - 78 - 712 - 816 - 7 Charge Per Foot, Weight Rated in accordance with ARI Standard 110, utilization range A .2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent All scrolls listed with a superscript D are Danfoss scrolls.
6 All scrolls listed with a superscript C are Copeland The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot (Inches)Refrigerant Connection Service Valve SizeA11. Including Fan Guard.* Adapter fitting required for 1-1/8 line Vapor0182737273/8 3/4 0243137270303537277/8 0363937270423937270483443320603843327/8 *246819-BTG-E-1106 Unitary Products Group3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 PhaseOutdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060 SRequired TXV1 TVM2A11 TVM2A11 TVM2A11 TVM2A11 TVM2C11 TVM2C11 TVM2C1 Factory R-22 Charge, lbs-oz7 - 16 - 68 - 78 - 78 - 712 - 816 - 7 Indoor Coil1,2 Additional Charge.
7 OzFC/MC/PC/UC18A2A0 FC/MC/PC/UC18B2A0 FC/MC/PC/UC24A2A 3 FC/MC/PC/UC24B2A 3 FC/MC/PC/UC30A2A 3 FC/MC/PC/UC30B2A 3 FC/MC/PC/UC36A2A 3 FC/MC/PC/UC36B2A 3 FC/MC/PC/UC36C2A 3 FC/MC/PC/UC42B2C 29 FC/MC/PC/UC42C2C 29 FC/MC/PC/UC48C2C 914 FC/MC/PC/UC48D2C 914 FC/PC/UC60C2C 77FC/MC/PC/UC60D2C 77MC61D2C 77HC18A2A0 HC30A2A 3 HC36B2A 2 HC42C2C 9 HC60C2C 77HD24A2A 3 HD36B2A 29 HD48C2C 14 HD60D2C 77 AHP18B2A0 AHP24B2A 3 AHP30B2A 2 AHP36C2A 9 AHP42C2C 9 AHP48D2C 147 AHP60D2C 77AV24B2A03 AV36C2A 29 AV48D2C 147 AV60D2C 7FC/MC/PC/UC18A3X0 FC/MC/PC/UC18B3X0 FC/MC/PC/UC24A3X 3 FC/MC/PC/UC24B3X 3 FC/MC/PC/UC30A3X 3 FC/MC/PC/UC30B3X 3 FC/MC/PC/UC36A3X 3 FC/MC/PC/UC36B3X 3 FC/MC/PC/UC36C3X 3 FC/MC/PC/UC42B3X 29 FC/MC/PC/UC42X3X 29 FC/MC/PC/UC48C3X 914 FC/MC/PC/UC48D3X 914 FC/PC/UC60C3X 77FC/MC/PC/UC60D3X 77MC61D3X 77 For Notes See Page Products GroupHC18A3X0 HC30A3X 3 HC36B3X 2 HC42C3X 9 HC60C3X 77HD24A3X 3 HD36B3X 29 HD48C3X 14 HD60D3X 77 AHP18B3X0 AHP24B3X 3 AHP30B3X 2 AHP36C3X 9 AHP42C3X 9 AHP48D3X 147 AHP60D3X 77AV24B3X03 AV36C3X 29 AV48D3X 147 AV60D3X 1477G1FA/G1UA024S14,17 G1FA/G1UA030S140 G1FA/G1UA036S14 3 G1FA/G1UA036S17,210 G1FA/G1UA048S17 29 G1FA/G1UA048S21 29 G1FA/G1UA060S21.
8 24 77G1FA036S14T 3 G1FA048S17T 2 G1FA048S21T 29 G1HA036H14T 3 G1HA036H17T 3 G1HA048H21T 29 G4FA030S14T2A0 G4FA036S14T2A3 G4FA036S17T2A0 G4FA036S21T2A0 G4FA048S17T2A 29 G4FA048S21T2A 29 G4FA060S21T2C 77G4FA060S24T2C 77G2FD024(S,H)14,170 G2FD030(S,H)170 G2FD035(S,H)140 G2FD036(S,H)17 3 G2FD036(S,H)21 G2FD042(S,H)21 29 G2FD046(S,H)17 29 G2FD048(S,H)21,24 914 G2FD060(S,H)24 77G2FD061H24 77G2FD036(S,H)17T 3 G2FD046(S,H)17T 2 G2FD048(S,H)21,24T 9 For Notes See Page R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060 SRequired TXV1 TVM2A11 TVM2A11 TVM2A11 TVM2A11 TVM2C11 TVM2C11 TVM2C1 Factory R-22 Charge, lbs-oz7 - 16 - 68 - 78 - 78 - 712 - 816 - 7 Indoor Coil1,2 Additional Charge, Oz246819-BTG-E-1106 Unitary Products Group5* This loose coil match does not achieve 13 :1.
9 Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter-connecting line Verify the orifice size and the additional charge required for the specific evaporator coil in the system using the above Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table Permanently mark the unit nameplate with the total system charge. Total System Charge = Base charge (as shipped) + adder forevaporator + adder for line If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice/TXV G4FD024H17T2A0 G4FD030H17T2A0 G4FD035H14T2A0 G4FD036H17T2A 3 G4FD042H21T2A 29 G4FD046H17T2A 29 G4FD048H21T2A 9 G4FD048H21T2C 14 G4FD048H24T2A 9 G4FD048H24T2C 14 G4FD060H24T2C 77G4FD061H24T2C 77G1HA024H140 G1HA036H14 3 G1HA036H17 2 G1HA048H21 29 G1HA060H24 77G1HD0240 G1HD036 3 G1HD048 2914 G1HD060 77G1NA030S17K0 G1NA030S21M0 G1NA036S17J 3 G1NA036S21C 3 G1NA036S17L 2 G1NA042S24W G1NA048S21D 2 14 G1NA060S24T 9 77F2RP/F2FP0240 F2RP/F2FP030 3 F2RP/F2FP040 29 F2RP/F2FP042 9 F3FP042 9 F2FP048 14 F2FP060 77F2FV060 77F4FP024H06T2A0 F4FP030H06T2A 3 F4FP040H06T2A 29
10 F4FP042H06T2A 9 F4FP048H06T2C 14 F4FP060H06T2C 77F4FV060H06T2C 77 FOOTNOTES:1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060 SRequired TXV1 TVM2A11 TVM2A11 TVM2A11 TVM2A11 TVM2C11 TVM2C11 TVM2C1 Factory R-22 Charge, lbs-oz7 - 16 - 68 - 78 - 78 - 712 - 816 - 7 Indoor Coil1,2 Additional Charge, Oz246819-BTG-E-11066 Unitary Products GroupAll dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon AND ELECTRICAL DATA - 3 PHASEMODELEABD-T030 SEABD-T036 SEABD-T042 SEABD-T048 SEABD-T060 SEABD-W030 SEABD-W036 SEABD-W042 SEABD-W048 SEABD-W060 SUnit Supply Voltage208-230V, 3 , 60Hz460V, 3 , 60 HzNormal Voltage Range 1187 to 252432 to 532 Minimum Circuit Overcurrent Device Amps 220202035401515151515 Min.