Example: marketing

Technical specifications - Hamilton Medical

Neonatal/Pediatric Dual limb breathing circuit set, unheated, single usePhysical characteristics PN 260180150 cm, swivel Y-piece, neonatal flow sensor , pressure linePN 260182300 cm, swivel Y-piece, neonatal flow sensor , pressure linePN 260170150 cm, swivel Y-piece, neonatal flow sensor , neonatal expiratory valve set, pressure linePN 260169300 cm, swivel Y-piece, neonatal flow sensor , neonatal expiratory valve set, pressure line PN 260241150 cm, swivel Y-piecePN 260244300 cm, swivel Y-pieceCompliance for breathing circuit sets in various lengths at 60 cmH2O pressurePNCircuit length (cm)Total circuit length (insp. + exp.) (cm)@ 60 cmH2O260170, 260180, , 260182, resistance for breathing circuit sets in various lengths at various flow rates (cmH2O/(l/min))PNCircuit length (cm)@ l/min@ 15 , 260180, , 260182, SpecificationsHamilton Medical Breathing CircuitsEnvironmental specificationsEnvironmentSpecificationsT emperatureOperation:-15 C to 40 C (5 F to 104 F)Storage:-20 C to 60 C (-4 F to 140 F)Relative humidityOperation and storage:5% to 95% relative humidity, noncondensingTechnical specificationsEnvironmentSpecificationsM aximum gas flow rate30 l/minLeakage< 30 ml/minMaximum working pressure200 cmH2 OFigure 1.

info@hamilton-medical.com www.hamilton-medical.com PN 689569.00 page 4 of 7 Hamilton Medical AG Via Crusch 8, 7402 Bonaduz Switzerland Requirements Diameter (ID, OD [mm]) Material Flow sensor calibration adapter 22 ID to 15 OD PP Expiratory valve set --- PP, Silicone, Metal Blue plug 23.8 OD LLD-PE

Tags:

  Medical, Flows, Sensor, Hamilton, Flow sensor, Hamilton medical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Technical specifications - Hamilton Medical

1 Neonatal/Pediatric Dual limb breathing circuit set, unheated, single usePhysical characteristics PN 260180150 cm, swivel Y-piece, neonatal flow sensor , pressure linePN 260182300 cm, swivel Y-piece, neonatal flow sensor , pressure linePN 260170150 cm, swivel Y-piece, neonatal flow sensor , neonatal expiratory valve set, pressure linePN 260169300 cm, swivel Y-piece, neonatal flow sensor , neonatal expiratory valve set, pressure line PN 260241150 cm, swivel Y-piecePN 260244300 cm, swivel Y-pieceCompliance for breathing circuit sets in various lengths at 60 cmH2O pressurePNCircuit length (cm)Total circuit length (insp. + exp.) (cm)@ 60 cmH2O260170, 260180, , 260182, resistance for breathing circuit sets in various lengths at various flow rates (cmH2O/(l/min))PNCircuit length (cm)@ l/min@ 15 , 260180, , 260182, SpecificationsHamilton Medical Breathing CircuitsEnvironmental specificationsEnvironmentSpecificationsT emperatureOperation:-15 C to 40 C (5 F to 104 F)Storage:-20 C to 60 C (-4 F to 140 F)Relative humidityOperation and storage:5% to 95% relative humidity, noncondensingTechnical specificationsEnvironmentSpecificationsM aximum gas flow rate30 l/minLeakage< 30 ml/minMaximum working pressure200 cmH2 OFigure 1.

2 Neonatal/pediatric breathing circuit with flow sensor (left) and pressure line for nCPAP/nCPAP-PC (right)Breathing circuit components, diameter, materialsComponentDiameter (ID/OD, mm)Material1 Elbow adapterID22/OD22/ID15PC2 Inspiratory limb150 cm, 300 cmPolyolefine3 Swivel Y-piece2 x ID15/OD10PP4 flow sensor , neonatalID15, patient sideOD15, ventilator sidePMMA, PVC, PE5 Expiratory limb150 cm, 300 cmPolyolefine6nCPAP-PS flow sensor position--PMMA, PVC, PET7 Pressure line (blue) with Luer pin (male) PVC, PC, PP8 Expiratory valve, neonatalID15/OD22PC, silicone, stainless steel9 Luer-L (female) with T-pieceOD10/OD15PP, PCHamilton Medical Breathing CircuitsAdult/Pediatric Coaxial breathing circuit set with expandable limb connection, unheated, single usePhysical characteristics PN 260206180 cmPN 260207180 cm, flow sensorPN 260184180 cm, flow sensor , expiratory valve ( Hamilton -G5/S1)PN 260257180 cm, flow sensor , expiratory valve ( Hamilton -C2/C3/C6)PN 260239240 cmPN 260240240 cm, flow sensorCompliance for breathing circuit sets in various lengths at 60 cmH2O pressurePNCircuit length (cm)@ 60 cmH2O260206, 260207, 260184, , resistance for breathing circuit sets in various lengths at various flow rates (cmH2O/(l/min))PNCircuit length (cm)@ 15 l/min@ 30 , 260207, 260184, , specificationsEnvironmentSpecificationsT emperatureOperation:-15 C to 50 C (5 F to 122 F)Storage:-20 C to 60 C (-4 F to 140 F)Relative humidityOperation and storage.

3 5% to 95% relative humidity, noncondensingTechnical specificationsParameterSpecificationsMax imum gas flow rate180 l/minLeakage< 50 ml/minMaximum working pressure200 cmH2 OFigure 2. Breathing circuit, coaxial, Adult/Ped, single useBreathing circuit components, diameter, materialsComponentDiameter (ID/OD, mm)Material1 Inspiratory connectorID22 SBC2 Coaxial inspiratory/expiratory limbExpiratory circuit: ID26 Inspiratory circuit: ID15 EVA, PP, PE3 Flow sensorID15/OD22, patient sideOD15, ventilator sidePSU, PVC, PE4 Expiratory connectorID22PP5 Hamilton -C2/C3/C6 Expiratory valve setID15/OD22PC, silicone, stainless steel6 Hamilton -C1/T1/MR1 Expiratory valve setID15/OD22PC, silicone, stainless steel7 Hamilton -G5/S1 Expiratory valve setID15/OD22 PCTG, PC, silicone, stainless steelHamilton Medical Breathing CircuitsAdult/Pediatric Coaxial breathing circuit set with elbow adapter for Hamilton -C1/T1/MR1, unheated, single usePhysical characteristics PN 260087180 cm, flow sensorPN 260094240 cm, flow sensorPN 260145300 cm, flow sensorPN 260144480 cm, flow sensorPN 260128180 cm, flow sensor , expiratory valvePN 260127240 cm, flow sensor , expiratory valvePN 260167300 cm, flow sensor , expiratory valvePN 260168480 cm, flow sensor .

4 Expiratory valveCompliance for breathing circuit sets in various lengths at 60 cmH2O pressurePNCircuit length (cm)@ 60 cmH2O260087, , , , resistance for breathing circuit sets in various lengths at various flow rates (cmH2O/(l/min))PNCircuit length (cm)@ 15 l/min@ 30 , , , , specificationsEnvironmentSpecificationsT emperatureOperation:-15 C to 50 C (5 F to 122 F)Storage:-20 C to 60 C (-4 F to 140 F)Relative humidityOperation and storage:5% to 95% relative humidity, noncondensingTechnical specificationsParameterSpecificationsMax imum gas flow rate90 l/min, kPaLeakage< 50 ml/minMaximum working pressure200 cmH2 OFigure 3. Hamilton -C1/T1/MR1 breathing circuit set, coaxial, Adult/Pediatric, single useBreathing circuit components, diameter, materialsComponentDiameter (ID/OD, mm)Material1To patient elbowID22/ID22PE2 From patient elbowID22/ID22PE3 Coaxial inspiratory/expiratory limbExpiratory circuit: ID26 Inspiratory circuit: ID15 EVA, PP, PE4 Flow sensorID15/OD22, patient sideOD15, ventilator sidePS, PVC, PE5 Hamilton -C1/T1/MR1 Expiratory valve setID15/OD22PC, silicone, stainless steelHamilton Medical Breathing CircuitsStandards and approvals (all breathing circuits)ClassificationClass EU IIa (in accordance with MDR)DeclarationThe breathing circuits were developed in accordance with pertinent international standards and FDA guidelines.

5 The breathing circuits are manufactured within an EN ISO 13485 certified quality management breathing circuits have been designed to comply with: Medical Device Regulation 2017/745 (MDR), ISO 5356-1,ISO 5367, ISO 10993-1, ISO 14971, EN 15223-1, EN 1041, and EN Medical Breathing CircuitsManufacturer: Hamilton Medical AGVia Crusch 8, 7402 Bonaduz, Switzerland( +41 (0) 58 610 10 are subject to change without notice. For all proprietary trademarks and third-party trademarks used by Hamilton Medical AG 2022 Hamilton Medical AG. All rights Medical Innovations GmbHAdam-Geisler-Stra e 1DE 82140 OlchingGermany)