Example: barber

Temperature Data Logger with LCD VFC 5000 TP Standard …

VFC-6000 LCDT emperature Data Logger with LCDFEATURES -35 to +80 C (-31 to +176 F) measurement range USB interface for set-up and data download Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit Temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium batter y and Windows control softw areThis standalone data Logger measures and stores up to 16,378 Temperature readings over a -35 to +80 C (-31 to +176 F) range. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data Logger into a PC s USB port and running the purpose designed softw are under Windows XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of Temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures.

VFC-6000 LCD Temperature Data Logger with LCD FEATURES • -35 to 80C - 31 to 176F measurement range • USB interface for set-up and data download

Tags:

  5000, Vfc 5000 tp

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Temperature Data Logger with LCD VFC 5000 TP Standard …

1 VFC-6000 LCDT emperature Data Logger with LCDFEATURES -35 to +80 C (-31 to +176 F) measurement range USB interface for set-up and data download Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit Temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium batter y and Windows control softw areThis standalone data Logger measures and stores up to 16,378 Temperature readings over a -35 to +80 C (-31 to +176 F) range. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data Logger into a PC s USB port and running the purpose designed softw are under Windows XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of Temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures.

2 The data Logger is supplied complete with a long-life lithium battery, which can typically allow * At 25 C and 1 minute logging rate MinimumTypicalMaximumUnitMeasurement range-35 (-31)+80 (+176) C ( F)Internal (1) C ( F)Accuracy (overall error) ( 1) ( 3) C ( F)Logging rateever y 10sever y 12hr-Operating Temperature range-35 (-31)+80 (+176) C ( F)1/2AA Lithium Batter y life1*YearControl Solution s EasyLog USB control softw are is supplied free of charge with each data Logger . Easy to install and use, the control softw are runs under Windows XP, Vista & 7. The softw are is used to set-up the data Logger as well as download, graph and export data to -WIN-USB (CONTROL SOFTWARE) Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms with optional LED indicator delay Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data roll over (allows unlimited logging periods by over writing the oldestdata when the memory is full)The latest ver sion of the control softw are may be downloaded free of charge from Applies to VFC-6000 LCD Page 1 of 888 311-0636 User-programmable alarm thresholds with optional LED indicator delay Delayed Alarm Settings: - select number of consecutive readings in an alarm condition before it is indicated by the LED s.

3 This standalone data Logger measures and stores up to 32,510 Temperature readings from the supplied thermistor probe which is attached via the socket at the base of the unit. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data Logger into a PC s USB port and running the purpose designed software under Windows XP, Vista, 7 or 8. Data can then be graphed, printed and exported to other VFC 5000 TP features an LCD and push-button which allows the user to cycle through the most recent, highest and lowest stored Temperature readings. The data Logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 6 5000 TP Temperature Probe Data Logger with LCD and USB Interface Applies to VFC 5000 TP Page 1 of 5 FEATURES -40 to +125 C (-40 to +257 F) probe measurement range High contrast LCD with Temperature display USB interface for set-up and data download User-programmable alarm thresholds Push button reset of Min/Max readings Status indication via red and green LEDs Immediate, delayed and push-to-start logging Supplied with 10 foot, high accuracy sensor probe Probe length can be easily extended with an extension cable Supplied complete with replaceable lithium battery and Windows control software 2 PT (freezer & fridge) NIST Certification of Calibration, ISO compliant* Operating Temperature applies to the data Logger unit only.

4 ** Depending on sample rate, ambient Temperature and use of LCD. SpecificationsMinimumTypicalMaximumUnitS upplied probe measurement range-40 (-40)+125 (+257) C ( F)Operating Temperature range * -10 (+14)+40 (+104) C ( F)Display resolution ( ) C ( F)Logging ( ) C ( F)Accuracy ( Logger error) ( ) C ( F)Logging rateevery 1 severy 12 hr-1/2AA Lithium Battery Life6**MonthORDERING INFORMATIONR eplacement Battery(1 Required)BAT 3V6 AA Standard Data Logger (Data Logger , 1m Thermistor Probe, Software on CD and Battery)VFC 5000 TPControl Solutions, Inc. 35851 Industrial Way, Suite D, St. Helens, OR 97051 888-311-0636 VFC-6000 LCDT emperature Data Logger with LCDFEATURES -35 to +80 C (-31 to +176 F) measurement range USB interface for set-up and data download Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit Temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium batter y and Windows control softw areThis standalone data Logger measures and stores up to 16,378 Temperature readings over a -35 to +80 C (-31 to +176 F) range.

5 The user can easily set up the logging rate and start-time, and download the stored data by plugging the data Logger into a PC s USB port and running the purpose designed softw are under Windows XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of Temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures. The data Logger is supplied complete with a long-life lithium battery, which can typically allow * At 25 C and 1 minute logging rate MinimumTypicalMaximumUnitMeasurement range-35 (-31)+80 (+176) C ( F)Internal (1) C ( F)Accuracy (overall error) ( 1) ( 3) C ( F)Logging rateever y 10sever y 12hr-Operating Temperature range-35 (-31)+80 (+176) C ( F)1/2AA Lithium Batter y life1*YearControl Solution s EasyLog USB control softw are is supplied free of charge with each data Logger .

6 Easy to install and use, the control softw are runs under Windows XP, Vista & 7. The softw are is used to set-up the data Logger as well as download, graph and export data to -WIN-USB (CONTROL SOFTWARE) Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms with optional LED indicator delay Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data roll over (allows unlimited logging periods by over writing the oldestdata when the memory is full)The latest ver sion of the control softw are may be downloaded free of charge from Applies to VFC-6000 LCD Page 1 of 888 311-0636 User-programmable alarm thresholds with optional LED indicator delay Delayed Alarm Settings: - select number of consecutive readings in an alarm condition before it is indicated by the LED s.

7 Applies to VFC 5000 TP Page 2 of 5 VFC 5000 TP Temperature Probe Data Logger with LCD and USB InterfaceWINDOWS CONTROL SOFTWAREV fcdataloggers s USB control software is supplied free of charge with each data Logger . Easy to install and use, the control software runs under Windows XP, Vista, 7 or 8. The software is used to set-up the data Logger as well as download, graph and export data to software allows the following parameters to be configured: Logger name C, F Logging rate (1s, 10s, 30s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full)The latest version of the control software may be downloaded free of charge from AND STATUS FUNCTIONST emperature scale symbolsMaximum/Minimum logged value symbolReadingThe VFC 5000 TP features a high contrast LCD and two LEDs.

8 The LCD shows logged Temperature values using seven segment numbers, along with symbols. The LCD can also show information regarding the logging status - see LCD INDICATION different functions are available on the display most recent logged Temperature , maximum logged Temperature and minimum logged Temperature . The push button is used to cycle through the functions and reset Minimum/Maximum readings. In addition, logging and alarm status are shown using two high intensity Solutions, Inc. 35851 Industrial Way, Suite D, St. Helens, OR 97051 888-311-0636 VFC-6000 LCDT emperature Data Logger with LCDFEATURES -35 to +80 C (-31 to +176 F) measurement range USB interface for set-up and data download Status indication via red, green and orange LEDs High contrast LCD, with two and a half digit Temperature display function Immediate, delayed and push-to-start logging Supplied with replaceable internal lithium batter y and Windows control softw areThis standalone data Logger measures and stores up to 16,378 Temperature readings over a -35 to +80 C (-31 to +176 F) range.

9 The user can easily set up the logging rate and start-time, and download the stored data by plugging the data Logger into a PC s USB port and running the purpose designed softw are under Windows XP, Vista, and 7. Data can then be graphed, printed and exported to other applications. The high contrast LCD can show a variety of Temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored temperatures. The data Logger is supplied complete with a long-life lithium battery, which can typically allow * At 25 C and 1 minute logging rate MinimumTypicalMaximumUnitMeasurement range-35 (-31)+80 (+176) C ( F)Internal (1) C ( F)Accuracy (overall error) ( 1) ( 3) C ( F)Logging rateever y 10sever y 12hr-Operating Temperature range-35 (-31)+80 (+176) C ( F)1/2AA Lithium Batter y life1*YearControl Solution s EasyLog USB control softw are is supplied free of charge with each data Logger .

10 Easy to install and use, the control softw are runs under Windows XP, Vista & 7. The softw are is used to set-up the data Logger as well as download, graph and export data to -WIN-USB (CONTROL SOFTWARE) Logger name C, F Logging rate (10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms with optional LED indicator delay Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data roll over (allows unlimited logging periods by over writing the oldestdata when the memory is full)The latest ver sion of the control softw are may be downloaded free of charge from Applies to VFC-6000 LCD Page 1 of 888 311-0636 User-programmable alarm thresholds with optional LED indicator delay Delayed Alarm Settings: - select number of consecutive readings in an alarm condition before it is indicated by the LED s.